Dell 610 Locking and Unlocking All Resources, Locking and Unlocking Configuration Resources

Page 43

The ICU includes a locking mechanism that enables you to allocate the system resources for all or for some functions of Plug and Play and PCI expansion cards. These expansion cards are dynamic, which means that they are allocated resources at system start-up. Device drivers that do not support this dynamic card configuration are referred to as static device drivers.

To determine whether your expansion card has static device drivers, check the documentation that came with the drivers. If you are using a static device driver, you need to permanently associate resources with a Plug and Play expansion card, instead of relying on the default Plug and Play behavior. Otherwise, the device driver might not be able to find the card the next time the system boots. This procedure is referred to as locking a card.

NOTE: The locking feature of the ICU is valid only for Plug and Play and PCI expansion cards.

Locking and Unlocking All Resources

To lock or unlock all the resources and configurations for a Plug and Play or PCI expansion card, perform the following steps:

1.If it is not already installed, install the Plug and Play or PCI expansion card. Then turn on the system. Complete steps 2 through 8 in "Installing an Expansion Card".

2.Start the ICU.

See "Starting the ICU".

3.Select Locking Enabled from the Advanced menu in the ICU window.

A check mark next to Locking Enabled signifies that the feature is active; a Lock button appears on the tool bar.

4.Select the Plug and Play or PCI expansion card that you want to lock or unlock from the Cards Configured in System list.

5.Click Lock or select Lock/Unlock Card from the Advanced menu. Both options toggle the lock state of the selected card.

Locking and Unlocking Configuration Resources

You can also lock and unlock individual resources for a Plug and Play or PCI expansion card. To do so, perform the following steps:

1.If it is not already installed, install the Plug and Play or PCI expansion card. Then turn on the system. Complete steps 2 through 8 in "Installing an Expansion Card".

2.Start the ICU.

See "Starting the ICU".

3.Select Locking Enabled from the Advanced menu in the ICU window.

A check mark next to Locking Enabled signifies that the feature is active; a Lock button appears on the tool bar.

4.Select the Plug and Play or PCI expansion card that you want to lock or unlock from the Cards Configured in System list.

5.Click Modify or select Modify Card from the Configure menu.

6.From the Card Configuration dialog box, select the function you want to lock or unlock.

7.Click Settings.

8.Modify the resource setting and/or resources offered on the Configuration Settings dialog box, if necessary. See "Modifying a Card" for more information.

9.Select Lock Resources.

The Lock Resources box toggles the lock state of the selected configuration setting.

10.Repeat steps 6 through 9 for any other configuration settings that you want to lock or unlock.

Image 43
Contents Initial release 19 May When Using Your Computer System When Working Inside Your Computer Protecting Against Electrostatic Discharge Overview System FeaturesPage Page Important Note to Windows NT 4.0 Users Reinstalling Windows NTBack Panel Front PanelCreating Disk Partitions for Windows NT Getting Help Connecting External DevicesSecurity Cable Slot and Padlock Ring Backing Up the Software Support Utilities Dell-Installed Software Support UtilitiesSoftware Support Utilities on Diskette Removing a Service System Utilities and ServicesAsset Tag Utility Assigning and Deleting an Owner Tag Dell AutoShutdown ServiceAssigning and Deleting an Asset Tag Number Asset 1234$ABCDAuto Power On Utility Dell ThermalShutdown ServiceInstalling the Auto Power On Utility Removing the Windows NT 4.0 Microsoft Updated Atapi Driver Microsoft Updated Atapi DriversSystem Setup Screen Entering the System Setup ProgramSystem-Setup Navigation Keys Keys Action Using the System Setup ProgramSystem Time System Setup OptionsEide Devices System DateDiskette Drive a and Diskette Drive B Primary Drive and Secondary DriveIf You Know the Drive-Type Number Boot SequenceIf You Have a Problem Hard-Disk Drive SequencePXE System MemoryReserved Memory CPU SpeedIntegrated Devices CPU IDsNIC PC Speaker Parallel Port ModeIDE Drive Interface Diskette InterfaceSystem Security System PasswordPassword Status Setup PasswordWakeup On LAN Report Keyboard ErrorsAuto Power On Keyboard NumLockSaving Monitor Power Power ManagementSaving Eide Hard-Disk Drive Power Asset Tag Thermal Power-OffSystem Data Options Assigning a System Password Using the System Password FeatureDeleting or Changing an Existing System Password Type the password and press EnterAssigning a Setup Password Using the Setup Password FeatureOperating With a Setup Password Enabled Deleting or Changing an Existing Setup Password Disabling a Forgotten PasswordInformation on resetting the chassis intrusion detector Responding to Error MessagesQuick Start About the ICU When to Run the ICUICU Database Backing Up the ICU Diskette Accessing HelpPreparing to Use the ICU Starting the ICUKeyss Action Adding a Listed CardCard Configuration Dialog Box Adding an Unlisted Card Available Settings List BoxSpecify Interrupt Dialog Box Specify I/O Port Dialog Box Modifying a CardRemoving a Card Locking and Unlocking Cards Saving the System ConfigurationViewing Resources Exiting the ICULocking and Unlocking All Resources Locking and Unlocking Configuration ResourcesPage NIC Connector and Indicators Connecting to a NetworkNetwork Cable Requirements Configuring the NICWindows NT 4.0 NIC Driver Setting the Network Frame Type Manually Configuring a 3Com PCI 3C905b NICReinstallation Speakers Connecting Audio DevicesRecord/Playback Devices Adjusting VolumeAdjusting Volume in Windows NT MicrophonesMuting the Internal Speaker Adjusting 3D SoundUsing Audio Utilities Installing Audio DriversScsi Device Considerations Scsi Drivers for Windows NT Installing Scsi DriversPage Before You Begin Safety First-For You and Your ComputerUnpacking Your Hardware Option Replacing the Computer Cover Removing the Computer CoverReplacing the Computer Cover Inside Your ComputerRotating the Power Supply Rotating the Power Supply Away From the System BoardExpansion Cards System Board FeaturesExpansion Slots Installing an Expansion CardRemoving the Filler Bracket Removing an Expansion CardAdding Memory Dimm Installation GuidelinesTotal Dimm Socket Desired Memory Pentium II Xeon Processor Upgrades Adding or Replacing a Pentium II Xeon Processor Slot 2 SEC Cartridge/Heat Sink Assembly Removal See Using the System Setup Program Replacing the System BatterySystem Battery and Battery Socket Obtaining technical assistance Drive Locations Removing and Replacing the Front BezelRemoving and Replacing Front-Panel Inserts Connecting DrivesDC Power Cable Connector Installing a Drive in a 5.25-Inch Drive BayRemoving a Drive Inserting the New Drive Into the Drive Bay Eide Drive Addressing Installing an Eide Hard-Disk Drive10. Removing the Hard-Disk Drive Bracket 11. Inserting a 1-Inch Hard-Disk Drive Into the Bracket 13. Attaching Hard-Disk Drive Cables Scsi Configuration Guidelines Installing Scsi DevicesScsi ID Numbers Device Termination General Procedure for Installing Scsi DevicesScsi Cables ALERT! Cover was previously removed Partitioning and Formatting Scsi Hard-Disk Drives System Information Table A-1. Technical Specifications ProcessorExpansion Bus System Clocks Ports and ConnectorsDrives Key Combinations Controls and IndicatorsPhysical Page Switches Jumpers and Switches-A General ExplanationJumpers Reserved do not remove jumper PARALLEL/SCSI System Board LabelsSerial and Parallel Ports Ports and ConnectorsSerial Port Connectors Parallel Port Connector Dparh External Scsi ConnectorKeyboard Connector Keyboard and Mouse ConnectorsNIC Connector Video ConnectorMouse Connector Microphone Jack USB ConnectorsTable B-9. Interrupt Assignments IRQ Line Used By/Available Interrupt AssignmentsLine-Out Jack Line-In JackTable B-10. Conventional Memory Map Address Range Use Memory AllocationsTable B-11. Upper Memory Map Address Range Use Table C-1. Configuration Utility Messages Probable Cause ICU Error MessagesCorrective Action Listed Card or Adding an Unlisted Card for instructions Table C-2. Configuration Manager Messages Configuration Manager MessagesChange to the db subdirectory on the diskette drive Page Cards mentioned Page Data Preservation Scheduling BackupsBackup Devices Recovering DataRecommended Tools and Accessories Cleaning System ComponentsCleaning the Computer, Monitor, and Keyboard Exteriors Humidity Cleaning DrivesTemperature Environmental FactorsESD AltitudeDust and Particles CorrosionMagnetism Power Source InterruptionsShock and Vibration Power Protection Devices Overview IC Notice Canada Only FCC Notices U.S. OnlyClass a Class B Class a ITE CE Notice European UnionEN 55022 Compliance Czech Republic Only Vcci Notice Japan OnlyClass B ITE MOC Notice South Korea OnlyClass a Device Class B Device Polish Center for Testing and Certification NoticeRound Rock, TX NOM Information Mexico OnlyExporter One Dell WayInformación para NOM únicamente para México Coverage During Year One Overview Limited Three-Year Warranty U.S. and Canada OnlyCoverage During Years Two and Three General Total Satisfaction Return Policy U.S. and Canada OnlyAscii AcpiADI AGPAspi AsicBBS BiosBTU Cmos CD-ROMDAT CPUDMA DimmDIN DIPDTE DmtfDpms DramEide ECCECP EepromEprom EMSFAT FTP FCCIces GUIHMA HpfsITE IPXIRQ ISAXMM LANLVD LED
Related manuals
Manual 96 pages 49.66 Kb Manual 230 pages 48.24 Kb