5.6.7 No Print or Light Print

If there is no printhead noise when the carriage traverses a document:

1.Check that the printhead is plugged into the carriage flex cables.

2.Check that the flex cables are plugged into the main PCB J3 and J4.

3.Replace timer U13 or MOSFET Q7 on the main PCB.

4.Repair or replace the main PCB with a bad driver circuit.

If there is printhead noise but there is no print or light print:

1.Correctly install the ribbon cartridge (see 3.1) or replace it if worn out.

2.Remove the cartridge and check for jammed ribbon.

3.Check that the cartridge knob rotates as the carriage traverses.

4.Check that QUIET MODE is turned off under 92 FUNCT.

5.Check the NORMAL and CQ DARKNESS parameters (see 3.5.4)

7.Check the printhead gap at both ends of the platen(see 5.4.1).

8.Clean the printhead (see 5.1.4).

9.Check that the carriage flange that clamps the drive belt is not bent down.

10.Check that the ribbon shield is pushed up until it clicks into place

5.6.8Print Quality

Symptom

Condition

Remedy

Print not dark enough on

Ribbon needs replacement

Replace ribbon cartridge.

receipts or multipart forms.

Ribbon installed incorrectly

See page 5 for ribbon installation

 

Increase print darkness setting

See “DARKNESS” service

 

 

parameters 3.5.4

Streaking or smearing over

Ribbon installed incorrectly

See page 3 for ribbon installation

printed lines.

Ribbon shield is

Replace ribbon shield.

 

missing/damaged

 

 

Ribbon is near end of life.

Replace ribbon cartridge.

 

Ribbon has too much ink.

 

 

Generic ribbon installed

Replace with Craden ribbon

Large gaps in printing or

Ribbon fabric is folded or

Replace ribbon cartridge.

sporadic light print occurs.

twisted.

 

 

Ribbon installed incorrectly

See page 3 for ribbon installation

 

Generic ribbon installed

Replace with Craden ribbon

A row of dots is missing

Printhead or printing circuit is

If unusable, initiate a service call

 

defective (unusual).

 

Print is darker on one side

Racked carriage shaft or

If unusable, initiate a service call

than on the other

misadjusted shaft cam

 

Ribbon getting tangled in

Ribbon installed incorrectly

See page 3 for ribbon installation

printer

Ribbon shield is damaged

Replace ribbon shield

 

Generic ribbon installed

Replace with Craden ribbon

Documents being torn

Ribbon shield is damaged

Replace ribbon shield

If print is light all across the print line, check as if printhead noise were present in 5.6.7. Print on a thick document will always be a little lighter than on a thin one.

If there is ribbon smear on the document and it is not very wrinkled:

1.Check that document is not too thick or printing is too close to a fold or edge (see 1.2)

2.Check for a displaced or missing ribbon shield.

3.Check printhead gap (see 5.4.1).

40

Image 45
Contents R I P H E R a L S R P O R a T I O N RevisionAirport HIGHWAY, PENNSAUKEN, NJ Record of Changes Pages AffectedALL Operation DP8 & DP9 Technical Manual Table of ContentsTheory of Operation MaintenanceTroubleshooting Recommended Spare Parts Recommended Service ToolsMajor Assembly Illustrations & Parts Lists Physical Characteristics Document CharacteristicsInterface Environment & StandardsInstallation Procedure Operation Ribbon Cartridge Loading ReshipmentKeypad Operation Display OperationKeypad & Display Panel Configuration Configuration Category PressDocument Insertion Printer Parameters DisplayRemarks Communication Parameters Override ParametersDisplay Remarks Diagnostics Power Up Diagnostics Service ParametersError Conditions Document Jam Enhanced DiagnosticsCarriage Fault Self TestHex Command Command SummaryProgramming AsciiESC K ESC HESC L ESC RPrint Commands Stops double height print High Density Graphics Commands Low Density Graphics CommandsDisplay Commands DC3Configuration Commands Status and Keypad CommandsDP XE DJ KB BZ BA Ascii Installing Craden Drivers on Windows 95 orMeaning DriversInstalling Craden Drivers on Windows NT, 2000 or XP Installing Craden USB Drivers on Windows NT, 2000 or XPUsing Printer Resident Device Fonts Interfacing Writing to the Printer LCD DisplayFunct Input Buffer OperationPin Signal Description Interface Signals & CablesPrinter Pin PC-25 Pin PC-9 Pin Signal Problem SolvingRollers Run at Power-Up or After Document Ejected Carriage Fault or No Carriage MotionNo Document Motion No Printing or Light PrintingDocument Drive Assembly Carriage Drive AssemblySwitching Power Supply Theory of Operation OverviewMain Printed Circuit Board Keypad/Display AssemblyMicroprocessor System Stepper Motor DriversPhase a I0A I1A Phase B I0B I1B Current U20 15 a Stepper Motor Drive CircuitPrinthead Drivers Keypad and Display Refer to Schematic #72135Sensors Character PrintingPrinthead Drive Circuit I LLubrication and Cleaning 5.1.1 Lubrication MaintenanceDocument Feed Roller Cleaning Sensor CleaningDocument Print Area Cleaning Printhead CleaningCabinet Exterior Cleaning Harsh, abrasive cleanersElectrical Adjustments Service Parameter SET-UP ProcedureMechanical Adjustments 5.4.1 Printhead Gap Ribbon Shield Removal / Replacement Ribbon Shield Face Inspection Document Drive Belt Tension Carriage Drive Belt TensionCarriage Shaft Cam and Shaft Rack Rear Document Roller Spring ForceAuto Alignment Gate Height Auto Alignment Gate RampFront Document Roller Spring Force Replacement ProceduresAuto Alignment Skew Sensor Calibration CabinetSensor PCB Power Supply PCBKeypad DisplayPrinthead Document MotorCarriage Drive Belt Document Drive BeltBasic Troubleshooting Procedure TroubleshootingNo Display Defective KeypadDefective Sensor No Document MotionNo Carriage Motion Symptom Condition Remedy No Print or Light PrintPrint Quality Erratic Document Feed or Mispositioning Missing DotsErratic Character Spacing or False Document Jams Interface InoperativeUse this flow chart to assist in troubleshooting Diagnostic FlowchartRecommended Service Tools Recommended Spare PartsDescription PART# Printer Diagram DP8 & DP9 Assembly Tree DWG REV. CAll assemblies not ending in X are used both on DP8 and DP9 Page Page Page Page Page Page Page