Citizen Systems CLP 1001, CLP 7202e, CLP 6002 Ribbon Tension Adjustments CLP 2001, 6001, 6002

Page 21

3.6 Ribbon Tension Adjustments (CLP 2001, 6001, 6002, 6401)

When the ribbon slips or wrinkles during printing, adjust the ribbon tension. The printer has already been factory set with the ribbon width of 114 mm. When using ribbon with a different width, adjust it according to the following procedure:

a)Hold the ribbon roll with one hand so that it does not turn.

b)Slightly push the knob toward the ribbon roll with the other hand and rotate the knob until the stopper comes to the desired position.

c)Gradually release the knob so that the stopper fits in the groove on the knob.

Set values to each ribbon width:

Ribbon width

Ribbon winding

Ribbon feed

Tension

section

section

 

 

Adjustment when ribbon slips

5

5

Mild

25.4 mm (1 in)

4

4

 

50.8 mm (2 in)

3

3

 

76.2 mm (3 in)

2

2

 

101.6 mm (4 in): factory setting

1

1

Strong

d)After printing, check for ribbon wrinkle or slippage. If it occurs, adjust it further according to the following procedure:

(1)When the ribbon wrinkles, the tension on the ribbon winding section should be increased.

(2)When the ribbon slips, the tension on the ribbon feed section should be decreased. If the problem is not resolved even when the tension on the ribbon feed section is set to 3, the tension on the ribbon winding section should be increased.

If ribbon problems are not resolved, consult our service personnel.

Ribbon feed section

Variable knob

Ribbon winding section

Mild

Strong

Strong

Mild

E N G L I S H

Image 21
Contents User’s Manual CLP 1001 CLP 6001, 6002 CLP 7201e, 7202e Page G L I S H On those compartments to service personnel Table of Contents Page Confirmation of Carton Contents Printer SetupPart Names and Functions 913 Front View Connection to a Computer Connection to PowerPrinter Setup Mode Normal Operating ModeControl Panel Control PanelNormal operating mode System Maintenance Mode Self-Test Mode And Hex DumpFactory Default Settings Adjusting the sensors for different mediaPaper & Ribbon Media InstallationRibbon Installation CLP 2001, 6001, 6002 Ribbon Installation CLP 7201e, 7202e Media Thickness Adjustments Media Width Adjustments Ribbon width Ribbon winding Ribbon feed Tension Section Ribbon Tension Adjustments CLP 2001, 6001, 6002Especially-easy-to-slip ribbon and media Ribbon Tension Adjustments CLP 7201e, 7202eAdjustable Media Sensor Error Messages TroubleshootingPrint Troubleshooting Interface Troubleshooting