CONNECTOR DESCRIPTIONS

The CLCI2000 Series Indexer will come with either one or two 37 Pin D-Sub Connectors. For a CLCI2001 and CLCI2002, there is only one connector. For a CLCI2003 and CLCI2004 there is a second connector that connects to the board via a 37 pin ribbon cable. This second connector will need a port location to screw down to. NOTE: This does not require an extra expansion slot to plug into, but only a space to screw down the connector. The connectors are Female D-Sub types. The pinouts for the first connector (axis A and B) is slightly different than the pinouts for the second connector (Axis C and D).

 

 

 

 

 

 

PIN

 

DESCRIPTION

PIN

FUNCTION

DESCRIPTION

 

FUNCTION

 

 

 

 

 

 

 

 

 

 

1

+5VDC

5 VOLT DC OUTPUT

20

A:HOME+

A: + HOME LIMIT SWITCH

2

OUT1

OUTPUT 1

21

A:HOME-

A: - HOME LIMIT SWITCH

3

OUT2

OUTPUT 2

22

A:HARD+

A: + HARD LIMIT SWITCH

4

OUT3

OUTPUT 3

23

A:HARD-

A: - HARD LIMIT SWITCH

5

OUT4

OUTPUT 4

24

0 VDC

O VOLT DC REFERENCE

6

OUT5

OUTPUT 5

25

B:CLOCK

B: CLOCK

7

0VDC

0 VOLT DC

26

B:DIR

B: DIRECTION

8

IN1

INPUT 1

27

B:EA

B: ENCODER CHANNEL A

9

IN2

INPUT 2

28

B:EB

B: ENCODER CHANNEL B

10

IN3

INPUT 3

29

B:EZ

B: ENCODER CHANNEL Z

11

IN4

INPUT 4

30

B:SOFT+

B: + SOFT LIMIT SWITCH

12

IN5

INPUT 5

31

B:SOFT-

B: - SOFT LIMIT SWITCH

13

A:CLOCK

A: CLOCK

32

B:HOME+

B: + HOME LIMIT SWITCH

14

A:DIR

A: DIRECTION

33

B:HOME-

B: - HOME LIMIT SWITCH

15

A:EA

A: ENCODER CH. A

34

B:HARD+

B: + HARD LIMIT SWITCH

16

A:EB

A: ENCODER CH. B

35

B:HARD-

B: - HARD LIMIT SWITCH

17

A:EZ

A: ENCODER CH. Z

36

0 VDC

O VOLT DC REFERENCE

18

A:SOFT+

A: + SOFT LIMIT SWITCH

37

NC

NO CONNECTION

19

A:SOFT-

A: - SOFT LIMIT SWITCH

 

 

 

 

 

 

 

 

 

DB37 PINOUT FOR AXES A & B

+5VDC

This is the +5VDC supplied by the computers power supply. See your Computer Manual for the specifications regarding this pin.

CLOCK SIGNALS

This is the signal that will be connected to the Step Motor Driver. The driver will take one step for every clock pulse sent to it. For instance, if a pulse train of 1000 pulses is sent at 50 Hz (50 clock pulses per second) to the driver the step motor will go 1000 steps, and will take 20 seconds. The output clock is TTL/CMOS compatible. The source current rating (Voh = 2.7 V) is 12mA. The sink current rating (Vol = 0.5 V) is 9mA. The clock signals are negative going.

7

Image 10
Contents CLCI2000 Series Disclaimer Limited WarrantyCopyright TrademarksTable of Contents General Description Main FeaturesDescription Packing InformationDPI65201 CLCI2004Ordering Information DPI65202AA37MMC-10 AA37MFC-10AA37MMC-6 AA2M37Specifications Wiring to the CLCI2000 InstallationInstalling the Board Address SettingsQuickstart with Quickbasic Clock Signals Connector Descriptions+5VDC Home Limit Direction SignalsSoft Limit Hard LimitInputs Encoder InputsOutputs Index ADR, Axis GO.CW ADR, Axis Programming with Anaheim Automation LibrariesProgramming with Quickbasic or Visualbasic for DOS Speed ConsiderationsCLCISUB1.BAS Library ONE.AT.MAX.CW ADDRESS, AXIS# ONE.AT.MAX.CCW ADDRESS, AXIS#ORIGIN.INDEX.CCW ADDRESS, AXIS# RAMP.TO.BASE.CW ADDRESS, AXIS# ORIGIN.INDEX.CW ADDRESS, AXIS#RAMP.TO.BASE.CCW ADDRESS, AXIS# RAMP.TO.STOP.CCW ADDRESS, AXIS#SLEW.AT.BASE.CCW ADDRESS, AXIS# SLEW.AT.BASE.CW ADDRESS, AXIS#TOP.OF.LOOP If GET.INPUTADDR,1 = 1 then Sample #1 Program SAMPLE1.BAS on the CLCI2000 DiskInitialize ADDR,AXIS Index ADDR,AXIS,5000HOME.TYPE.1 Sample #2 Program SAMPLE2.BAS on the CLCI2000 DiskInitialize ADDR, Axis LIMIT.CONTROL ADDR, AXIS, 0, 0CLCISUBS.CPP Program Function Definitions Originindexccw ADDRESS, Axis Oneatmaxccw ADDRESS, AxisOneatmaxcw ADDRESS, Axis Originindexcw ADDRESS, AxisSoftinputccw ADDRESS, Axis Slewatbaseccw ADDRESS, AxisSlewatbasecw ADDRESS, Axis Softinputcw ADDRESS, AxisObject Command1Procedure Click Using the CLCI2000 Indexer with WindowsUsing the DLL with Visual Basic for Windows Programming in WindowsWIN2000.BAS Program Listing Anaheim Automation DLL Library SupportRunning the Software CLCI2004 Program GeneratorFunction Window F4- Terminal F1 InsertF3 Delete F5 SaveF3 Clear Program F1 Prog StopF2 Single Step F4 Printing a ProgramCommand Window Command Dictionary CLCI2004 Program Generator Command DictionaryCommand Summary Direction + orFinish Move no value Encoder Resolution any numberEncoder Window any integer GO Index no valueJump to Line 1 to UNITS/SCALE any number MAX Setting not in HZ Register # Bits Setting Range DescriptionBase Setting not in HZ Ramp SettingCommand Buffer Register Description of Command Input and Output Control Commands Initial Setup CommandsList of Equations Acceleration = MAX Speed Base Speed / TUP Page