9450 Operator’s Handbook
3.Press [Feed] once. The LED indicator blinks once.
Press [Feed] ... | To set the baud rate to ... |
|
|
Once | 38,400 |
|
|
Twice | 19,200 |
|
|
Three times | 9600 |
|
|
Four times | 4800 |
|
|
Five times | 2400 |
|
|
Six times | 1200 |
|
|
The printer verifies your selection by flashing the LED indicator once for each time you pressed [Feed].
4.Press [Feed] twice. The LED indicator blinks twice.
Press [Feed] ... | To set ... |
|
|
Once | No parity, 8 data bits, 1 stop bit |
|
|
Twice | Even parity, 7 data bits, 1 stop bit |
|
|
The printer verifies your selection by flashing the LED indicator once for each time you pressed [Feed].
5.Press [Feed] three times. The LED indicator blinks three times.
Press [Feed] ... | To set flow control to ... |
|
|
Once | XON/XOFF |
|
|
Twice | DTR |
|
|
The printer verifies your selection by flashing the LED indicator once for each time you pressed [Feed].
6.Press [Feed] four times to exit the communications parameter set mode. A test label prints automatically, showing the new communications parameters. The LED indicator goes off.