Metrologic Instruments IS1000 manual Code, Standard/Full Ascii, Full Ascii Extended

Page 32

3.2.Code 39

This is the most popular alpha-numeric bar code symbology. It has a set of 43 characters (alphanumeric and a few symbols) and can be used with or without a check digit.

3.2.1.Standard/Full ASCII

The Code 39 Full ASCII option allows the transmission of the 128 ASCII characters. Each ASCII character is a combination of two Code 39 characters. It can be very useful specially to transmit control characters (STX, ETX, TAB, EOT…) as preambles or postambles in a message (see appendix 6.3, page 58). The Code 39 Full ASCII Table is listed in appendix 6.10, page 70.

STANDARD *

FULL ASCII

3.2.2.Full ASCII Extended

In Keyboard-Wedge mode, function keys like F1 to F12, t, HOME, CLEAR… can be emulated using this function.

The function key to be emulated is represented by two Code 39 characters from the Code 39 Full ASCII Extended Table (see appendix 6.8, page 65), which can be part of the symbol or separate from it.

DISACTIVATED *

ACTIVE ON TWO CHARACTERS

PRECEDED BY A DASH

(part of or separate from the symbol)

ACTIVE ON TWO CHARACTERS

ACTIVE ONLY ON TWO CHARACTERS

(part of or separate from the symbol)

SEPARATE FROM THE SYMBOL

!Note:

The function key value to be emulated can be set as a preamble or a postamble of message (see appendix 6.3, page 58).

START OF CONFIGURATION

END OF CONFIGURATION

 

 

IS1000 – Configuration Guide

24

Image 32
Contents IS1000 Series Page Mlpn Metrologic Instruments Italia S.r.L Table of Contents UCC/EAN Editing Mode Appendixes Intentionally left blank Introduction Symbologies Default Configuration factory setting Default ConfigurationIntentionally left blank Communication Modes RS232 Baud RateData Bits Parity Stop BitsEnd of Message Character Time-Out Between Characters RTS/CTS Protocol ACK/NAK ProtocolXON/XOFF Protocol PC-Term Mode Keyboard-Wedge PC Keyboard Type Upper / Lower Case Options Types of Numeric Characters Wyse Time-Out P.O.S. Point Of Sale Systems OciaWand Emulation Transmission SpeedBar/Space Polarity Idle StateLaser Emulation Symbologies Symbology Selection Standard 2/5 MSI Plessey Telepen Code Matrix 2/5 Iata Full Ascii Extended CodeStandard/Full Ascii Multiread Modulo 43 Check CharacterPharmacode or Pharma 32/39 CIP CodeStart/Stop Modulo 43 AlgorithmFixed Lengths Authorized and Set Upon First Readings Interleaved 2/5Fixed Lengths Authorized and Set Using the Numeric Pad Variable Lengths Authorized Transformations UPC/EANTypes of UPC/EAN Authorized Add-On Options Leading Prefixes for P.O.S. Systems Flag OptionIsbn Conversion Check Digit OptionsProduct Code Monarch/Codabar ConcatenationCheck Character FNC2 FunctionUCC/EAN Start FNC1 ID Data StopStart/Stop Types Standard 2/5Number of Lengths Authorized MSI Variable or Fix LengthsDouble Check Digit Modulo Single Check Digit ModuloPlessey TelepenMatrix 2/5 Types of Start/StopCheck Digit Fixed or Variable LengthsSetting the Authorized Lengths 16 W7 Iata15. BC Identifier with Three Characters Leading IdentifiersIdentifier with One Character Decoding Selectivity Intentionally left blank Operating Modes Simple AcknowledgmentHost System Acknowledgment On File / Not On FileSetting the On File Character Setting the Not On File CharacterBell Timer T1 Timer T2 Timer T3Editing Mode IS1000 Configuration Guide Appendixes Number of Re-transmissions Adjustment of the Beep Sound 6.2.1. Laser Reader Radio BasePreamble / Postamble Preamble CharacterPostamble Character Clear BufferConversion of Characters First CharacterIS1000 Configuration Guide Second Character Rolling Buffer Mode Transmission of the Full Ascii Character Set Displaying the Firmware Level Code 39 Full Ascii Extended Table Reserved Multiread character Table IS1000 Configuration Guide IS1000 Configuration Guide Code 39 Full Ascii Table AsciiDEL NUL SOH STX ETX EOT ENQ ACK BEL DLE DC1 DC2 DC3 DC4 NAK SYN ETB Can SUB ESC IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide DEL Intentionally left blank Numeric Pad Samples of Bar Codes UPC E UPC a Intentionally left blank