Metrologic Instruments IS1000 manual Check Character, FNC2 Function

Page 44

3.6.Code 128

This symbology offers a great flexibility with its three sets of characters:

Set A: upper case alphanumeric characters and all ASCII control characters.

Set B: upper and lower case alphanumeric characters and some symbols.

Set C: numeric only but which a very high density of characters per inch.

Good quality printed codes are recommended due to the continuous structure (no gaps between characters) and the four types of bar and space widths.

It works with a modulo 103 check character as the last character.

!Note:

The UCC/EAN 128 options are described on next page.

3.6.1.Check Character

VERIFIED BUT NOT TRANSMITTED *

NOT VERIFIED BUT TRANSMITTED

VERIFIED AND TRANSMITTED

3.6.2.FNC2 Function

This function permits the temporary storage of a code in the decoder if this code starts with the FNC2 character. The message buffered will be concatenated and transmitted with next code having no FNC2 character.

FNC2 NOT ACTIVATED *

FNC2 ACTIVATED

START OF CONFIGURATION

END OF CONFIGURATION

 

 

IS1000 – Configuration Guide

36

Image 44
Contents IS1000 Series Page Mlpn Metrologic Instruments Italia S.r.L Table of Contents UCC/EAN Editing Mode Appendixes Intentionally left blank Introduction Symbologies Default Configuration factory setting Default ConfigurationIntentionally left blank Communication Modes RS232 Baud RateData Bits Parity Stop BitsEnd of Message Character Time-Out Between Characters RTS/CTS Protocol ACK/NAK ProtocolXON/XOFF Protocol PC-Term Mode Keyboard-Wedge PC Keyboard Type Upper / Lower Case Options Types of Numeric Characters Wyse Time-Out P.O.S. Point Of Sale Systems OciaWand Emulation Transmission SpeedBar/Space Polarity Idle StateLaser Emulation Symbologies Symbology Selection Standard 2/5 MSI Plessey Telepen Code Matrix 2/5 Iata Full Ascii Extended CodeStandard/Full Ascii Multiread Modulo 43 Check CharacterPharmacode or Pharma 32/39 CIP CodeStart/Stop Modulo 43 AlgorithmFixed Lengths Authorized and Set Upon First Readings Interleaved 2/5Fixed Lengths Authorized and Set Using the Numeric Pad Variable Lengths Authorized Transformations UPC/EANTypes of UPC/EAN Authorized Add-On Options Leading Prefixes for P.O.S. Systems Flag OptionIsbn Conversion Check Digit OptionsProduct Code Monarch/Codabar ConcatenationCheck Character FNC2 FunctionUCC/EAN Start FNC1 ID Data StopStart/Stop Types Standard 2/5Number of Lengths Authorized MSI Variable or Fix LengthsDouble Check Digit Modulo Single Check Digit ModuloPlessey TelepenMatrix 2/5 Types of Start/StopCheck Digit Fixed or Variable LengthsSetting the Authorized Lengths 16 W7 Iata15. BC Identifier with Three Characters Leading IdentifiersIdentifier with One Character Decoding Selectivity Intentionally left blank Operating Modes Simple AcknowledgmentHost System Acknowledgment On File / Not On FileSetting the On File Character Setting the Not On File CharacterBell Timer T1 Timer T2 Timer T3Editing Mode IS1000 Configuration Guide Appendixes Number of Re-transmissions Adjustment of the Beep Sound 6.2.1. Laser Reader Radio BasePreamble / Postamble Preamble CharacterPostamble Character Clear BufferConversion of Characters First CharacterIS1000 Configuration Guide Second Character Rolling Buffer Mode Transmission of the Full Ascii Character Set Displaying the Firmware Level Code 39 Full Ascii Extended Table Reserved Multiread character Table IS1000 Configuration Guide IS1000 Configuration Guide Code 39 Full Ascii Table AsciiDEL NUL SOH STX ETX EOT ENQ ACK BEL DLE DC1 DC2 DC3 DC4 NAK SYN ETB Can SUB ESC IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide DEL Intentionally left blank Numeric Pad Samples of Bar Codes UPC E UPC a Intentionally left blank