Metrologic Instruments IS1000 manual Code 39 Full Ascii Extended Table

Page 73

6.8.Code 39 Full ASCII Extended Table

 

●A

 

●B

 

 

 

 

FIELD EXIT

FIELD ADVANCE

 

●C

 

●D

 

 

 

 

ENTER

SEND

 

●E

 

●F

 

 

 

 

TAB -

RETURN

 

●G

 

●H

 

 

 

 

RESET, RESTORE

HOME

 

●I

 

●J

 

 

 

 

t

s

 

●K

 

●L

 

 

 

 

u

v

●M

CLEAR

IS1000 – Configuration Guide

65

Image 73
Contents IS1000 Series Page Mlpn Metrologic Instruments Italia S.r.L Table of Contents UCC/EAN Editing Mode Appendixes Intentionally left blank Introduction Symbologies Default Configuration Default Configuration factory settingIntentionally left blank Communication Modes Baud Rate RS232Stop Bits Data Bits ParityEnd of Message Character Time-Out Between Characters XON/XOFF Protocol ACK/NAK ProtocolRTS/CTS Protocol PC-Term Mode Keyboard-Wedge PC Keyboard Type Upper / Lower Case Options Types of Numeric Characters Wyse Time-Out Ocia P.O.S. Point Of Sale SystemsTransmission Speed Wand EmulationIdle State Bar/Space PolarityLaser Emulation Symbologies Symbology Selection Standard 2/5 MSI Plessey Telepen Code Matrix 2/5 Iata Standard/Full Ascii CodeFull Ascii Extended Modulo 43 Check Character MultireadCIP Code Pharmacode or Pharma 32/39Modulo 43 Algorithm Start/StopInterleaved 2/5 Fixed Lengths Authorized and Set Upon First ReadingsFixed Lengths Authorized and Set Using the Numeric Pad Variable Lengths Authorized Types of UPC/EAN Authorized UPC/EANTransformations Add-On Options Flag Option Leading Prefixes for P.O.S. SystemsProduct Code Check Digit OptionsIsbn Conversion Concatenation Monarch/CodabarFNC2 Function Check CharacterStart FNC1 ID Data Stop UCC/EANNumber of Lengths Authorized Standard 2/5Start/Stop Types Variable or Fix Lengths MSIDouble Check Digit Modulo Single Check Digit ModuloTelepen PlesseyTypes of Start/Stop Matrix 2/5Check Digit Fixed or Variable LengthsSetting the Authorized Lengths 15. BC Iata16 W7 Identifier with One Character Leading IdentifiersIdentifier with Three Characters Decoding Selectivity Intentionally left blank Simple Acknowledgment Operating ModesOn File / Not On File Host System AcknowledgmentSetting the Not On File Character Setting the On File CharacterBell Timer T1 Timer T3 Timer T2Editing Mode IS1000 Configuration Guide Appendixes Number of Re-transmissions Radio Base Adjustment of the Beep Sound 6.2.1. Laser ReaderPreamble Character Preamble / PostamblePostamble Character Clear BufferFirst Character Conversion of CharactersIS1000 Configuration Guide Second Character Rolling Buffer Mode Transmission of the Full Ascii Character Set Displaying the Firmware Level Code 39 Full Ascii Extended Table Reserved Multiread character Table IS1000 Configuration Guide IS1000 Configuration Guide Ascii Code 39 Full Ascii TableDEL NUL SOH STX ETX EOT ENQ ACK BEL DLE DC1 DC2 DC3 DC4 NAK SYN ETB Can SUB ESC IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide DEL Intentionally left blank Numeric Pad Samples of Bar Codes UPC E UPC a Intentionally left blank