Metrologic Instruments IS1000 manual Multiread, Modulo 43 Check Character

Page 33

3.2.3.Multiread

DISACTIVATED *

ACTIVATED

The Multiread function permits the temporary storage of one or more codes in the decoder's memory which will then be transmitted in a single string message.

To operate the Multiread function, the desired group of codes to be first stored must have a Multiread Character as the leading character. This character can be chosen in the Multiread Character Table (see appendix 6.9, page 67; default is SPACE character) after reading code Activated. The transmission will start once a code having no Multiread Character is read.

3.2.4.Modulo 43 Check Character

In the case of high level security applications, a check character can be integrated as the last character in the code and verified before transmission.

NOT VERIFIED *

VERIFIED AND TRANSMITTED

VERIFIED AND NOT TRANSMITTED

!Note:

See page 27 for the calculation algorithm of Code 39 Modulo 43 Check Character.

START OF CONFIGURATION

END OF CONFIGURATION

 

 

IS1000 – Configuration Guide

25

Image 33
Contents IS1000 Series Page Mlpn Metrologic Instruments Italia S.r.L Table of Contents UCC/EAN Editing Mode Appendixes Intentionally left blank Introduction Symbologies Default Configuration Default Configuration factory settingIntentionally left blank Communication Modes Baud Rate RS232Stop Bits Data Bits ParityEnd of Message Character Time-Out Between Characters ACK/NAK Protocol XON/XOFF ProtocolRTS/CTS Protocol PC-Term Mode Keyboard-Wedge PC Keyboard Type Upper / Lower Case Options Types of Numeric Characters Wyse Time-Out Ocia P.O.S. Point Of Sale SystemsTransmission Speed Wand EmulationIdle State Bar/Space PolarityLaser Emulation Symbologies Symbology Selection Standard 2/5 MSI Plessey Telepen Code Matrix 2/5 Iata Code Standard/Full AsciiFull Ascii Extended Modulo 43 Check Character MultireadCIP Code Pharmacode or Pharma 32/39Modulo 43 Algorithm Start/StopInterleaved 2/5 Fixed Lengths Authorized and Set Upon First ReadingsFixed Lengths Authorized and Set Using the Numeric Pad Variable Lengths Authorized UPC/EAN Types of UPC/EAN AuthorizedTransformations Add-On Options Flag Option Leading Prefixes for P.O.S. SystemsCheck Digit Options Product CodeIsbn Conversion Concatenation Monarch/CodabarFNC2 Function Check CharacterStart FNC1 ID Data Stop UCC/EANStandard 2/5 Number of Lengths AuthorizedStart/Stop Types Variable or Fix Lengths MSIDouble Check Digit Modulo Single Check Digit ModuloTelepen PlesseyTypes of Start/Stop Matrix 2/5Check Digit Fixed or Variable LengthsSetting the Authorized Lengths Iata 15. BC16 W7 Leading Identifiers Identifier with One CharacterIdentifier with Three Characters Decoding Selectivity Intentionally left blank Simple Acknowledgment Operating ModesOn File / Not On File Host System AcknowledgmentSetting the Not On File Character Setting the On File CharacterBell Timer T1 Timer T3 Timer T2Editing Mode IS1000 Configuration Guide Appendixes Number of Re-transmissions Radio Base Adjustment of the Beep Sound 6.2.1. Laser ReaderPreamble Character Preamble / PostamblePostamble Character Clear BufferFirst Character Conversion of CharactersIS1000 Configuration Guide Second Character Rolling Buffer Mode Transmission of the Full Ascii Character Set Displaying the Firmware Level Code 39 Full Ascii Extended Table Reserved Multiread character Table IS1000 Configuration Guide IS1000 Configuration Guide Ascii Code 39 Full Ascii TableDEL NUL SOH STX ETX EOT ENQ ACK BEL DLE DC1 DC2 DC3 DC4 NAK SYN ETB Can SUB ESC IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide IS1000 Configuration Guide DEL Intentionally left blank Numeric Pad Samples of Bar Codes UPC E UPC a Intentionally left blank