Meridian Data 16i manual Controller Module LEDs, Name Color Status

Page 39

Chapter 3 Subsystem Monitoring

Figure 3-11: Drive Tray LEDs

Name

Color

Status

 

 

FLASHING indicates data is being written

Drive Busy

Blue

to or read from the drive. The drive is busy.

OFF indicates that there is no activity on the

 

 

 

 

disk drive.

 

 

 

 

Green/

GREEN indicates that the drive bay is

Power Status

populated.

Red

 

RED indicates that the disk drive has failed.

 

 

 

 

 

 

Table 3-2: Drive Tray LED Definitions

Formatted: Bullets and Numbering

3.2.3 Controller Module LEDs

The LEDs on the rear-facing faceplate of the RAID controller are shown in Figure 3- 12. The LEDs on the controller’s faceplate that can be accessed from the rear of the enclosure are numbered from 1 to 6. The definitions are shown below.

Figure 3-12: Controller Module LEDs

Name

Color

Status

 

 

 

Ctlr Status

Green/

Green indicates that the RAID subsystem is

Amber

operating healthily.

 

 

 

 

3-3

Image 39
Contents Installation and Hardware Reference Manual Copyright Contact InformationFCC Class B Radio Frequency Interference Statement Electric Shock WarningCCC Safety Precautions Precautions and InstructionsESD Precautions About This Manual Who should read this manual?Conventions Software and Firmware Updates StepsLists Table of Contents Subsystem Monitoring Appendix a Technical Specifications This page intentionally left blank Page Product Introduction Product OverviewEnclosure Chassis Chassis Overview Front Panel Overview Physical DimensionsRear Panel Overview Hard Drive NumberingBackplane Board Subsystem ComponentsRAID Controller Module Drive TraysController Module Interfaces 2-port version Controller Module InterfacesPower Supply Units Dimm Module5 BBU PSU Module Cooling Modules1 I2C bus LED IndicatorsFirmware FW Audible Alarms Hot-swappable ComponentsHot-swap Capabilities Normalized Airflow ComponentsThis page intentionally left blank Page Introduction Chapter Hardware InstallationSecurStor 16i Installation and Hardware Reference Manual General Installation Procedure Installation Overview Installation Procedure FlowchartUnpacking the Subsystem Installation Procedure BBU InstallationBBU Module Installation Overview BBU Warnings and PrecautionsLoosening the BBU Retention Screws Hard Drive Installation Prerequisites Hard Drive InstallationFront View of an Individual Drive Tray Drive Tray Key-lock Rotation Rack/Cabinet InstallationPage Subsystem Monitoring Overview Chapter Subsystem MonitoringStatus-indicating LEDs Brief Overview of the LEDsDrive Tray LEDs Name Color Status Controller Module LEDsAmber Restore Nvram Defaults a Push ButtonEthernet Port LEDs How to use the button?PSU LEDs BBU Module LEDColor Status Cooling Module LEDsDefault Threshold Values Audible AlarmFailed Devices I2C MonitoringPage Cabling Connection OverviewSample Topology Direct-Attached, Dual-path Connection Host Connection TopologiesNetwork Topologies Points of FailureSample Topology Multiple Servers Each with Dual Connections ISCSI Topology and Host LUN Mapping Sample Topology Connection and Host LUN Mapping Power OnPower On Procedure Power On EnclosureCheck List Power Switches Power On Status CheckStop I/O access to the system Power Off ProcedureMaintenance General Notes on Component ReplacementOverview Overview Replacing Controller Module ComponentsRemoving the Controller Module Subsystem Maintenance and UpgradingLoosening the Retention Screws from the BBU Module Removing the Controller Module from Chassis Replacing the Controller ModuleMemory Module Installation Overview Replacing or Upgrading Memory ModulesSelecting the Memory Modules Removing a Dimm Module Dimm Module InstallationFault Conditions Replacing a Faulty BBUReplacing a Faulty BBU Remove the Retention Screws from BBU Faceplate Install the BBU Module Printed Text on PSU Handle Replacing a Failed PSU ModulePSU Parts Identification Replacing the PSU Module10 Removing the PSU Retention Screw Cooling Module Maintenance Replacing a Cooling Module Remove the cooling fan assembly by the following steps13 Removing a Cooling Module Replacing a Failed Hard Drive Hard Drive Maintenance Overview15 Front View of an Individual Drive Tray Replacing a Hard Drive16 Opening the Drive Tray Front Flap 18 Loosening the Hard Drive Screws Page Appendix a Certifications Architecture ConfigurationDrive Tray Specifications RAID Management SecurStor 16i Installation and Hardware Reference Manual COM1 Serial Port Cable Appendix B PinoutsCOM2 Serial Port Cable to UPS Null ModemEthernet Port Pinouts STP LAN Cable Connect the PSU Module Power Cords Appendix C Uninterruptible Power SupplySet the Baud Rate Connect COM2 SecurStor 16i Installation and Hardware Reference ManualUPS Messages Normal Operational StatusUPS Message Summary Message 5 Warning UPS Battery Low 50%This page is intentionally left blank