Meridian Data 16i manual Replacing a Cooling Module

Page 70

SecurStor 16i Installation and Hardware Reference Manual

5.6.2 Replacing a Cooling Module

If one of the cooling modules fails, it must be replaced as soon as possible. The cooling module is secured to the PSU module with the six (6) screws from the top. To replace the cooling module, follow the steps below:

WARNING!

The fan replacement process should be completed within five (5) minutes. If the process takes too long, the accumulated heat can damage the subsystem.

Step 1. To remove the cooling module, remove the PSU module first. Please follow the PSU removal process listed in the previous discussion.

Step 2. Use a medium-size Phillips screwdriver to remove the six screws from the top of the PSU module. (See Figure 5-12:Removing a Cooling Module)

Figure 5-12: Removing a Cooling Module

Step 3. Remove the cooling fan assembly by the following steps:

Step 3-1. Make sure the PSU handle is in the down position so that you can grab the edge of the cooling fan assembly.

Step 3-2. Use your thumb and middle fingers to seize the cooling assembly, your thumb by the upper edge of the fan guard and your middle finger at the hemispheric indent.

5-16

Image 70
Contents Installation and Hardware Reference Manual Contact Information CopyrightElectric Shock Warning FCC Class B Radio Frequency Interference StatementCCC Precautions and Instructions Safety PrecautionsESD Precautions Who should read this manual? About This ManualConventions Steps Software and Firmware UpdatesLists Table of Contents Subsystem Monitoring Appendix a Technical Specifications This page intentionally left blank Page Product Overview Product IntroductionEnclosure Chassis Chassis Overview Physical Dimensions Front Panel OverviewHard Drive Numbering Rear Panel OverviewSubsystem Components Backplane BoardDrive Trays RAID Controller ModuleController Module Interfaces Controller Module Interfaces 2-port versionDimm Module Power Supply Units5 BBU Cooling Modules PSU ModuleLED Indicators 1 I2C busHot-swappable Components Firmware FW Audible AlarmsHot-swap Capabilities Components Normalized AirflowThis page intentionally left blank Page Chapter Hardware Installation IntroductionSecurStor 16i Installation and Hardware Reference Manual General Installation Procedure Installation Procedure Flowchart Installation OverviewUnpacking the Subsystem BBU Warnings and Precautions BBU InstallationBBU Module Installation Overview Installation ProcedureLoosening the BBU Retention Screws Hard Drive Installation Hard Drive Installation PrerequisitesFront View of an Individual Drive Tray Rack/Cabinet Installation Drive Tray Key-lock RotationPage Chapter Subsystem Monitoring Subsystem Monitoring OverviewBrief Overview of the LEDs Status-indicating LEDsDrive Tray LEDs Controller Module LEDs Name Color StatusRestore Nvram Defaults a Push Button AmberHow to use the button? Ethernet Port LEDsBBU Module LED PSU LEDsCooling Module LEDs Color StatusAudible Alarm Default Threshold ValuesI2C Monitoring Failed DevicesPage Connection Overview CablingPoints of Failure Host Connection TopologiesNetwork Topologies Sample Topology Direct-Attached, Dual-path ConnectionSample Topology Multiple Servers Each with Dual Connections ISCSI Topology and Host LUN Mapping Power On Sample Topology Connection and Host LUN MappingPower On Enclosure Power On ProcedureCheck List Power On Status Check Power SwitchesPower Off Procedure Stop I/O access to the systemGeneral Notes on Component Replacement MaintenanceOverview Replacing Controller Module Components OverviewSubsystem Maintenance and Upgrading Removing the Controller ModuleLoosening the Retention Screws from the BBU Module Replacing the Controller Module Removing the Controller Module from ChassisReplacing or Upgrading Memory Modules Memory Module Installation OverviewSelecting the Memory Modules Dimm Module Installation Removing a Dimm ModuleReplacing a Faulty BBU Fault ConditionsReplacing a Faulty BBU Remove the Retention Screws from BBU Faceplate Install the BBU Module Replacing a Failed PSU Module Printed Text on PSU HandleReplacing the PSU Module PSU Parts Identification10 Removing the PSU Retention Screw Cooling Module Maintenance Remove the cooling fan assembly by the following steps Replacing a Cooling Module13 Removing a Cooling Module Hard Drive Maintenance Overview Replacing a Failed Hard DriveReplacing a Hard Drive 15 Front View of an Individual Drive Tray16 Opening the Drive Tray Front Flap 18 Loosening the Hard Drive Screws Page Appendix a Certifications Configuration ArchitectureDrive Tray Specifications RAID Management SecurStor 16i Installation and Hardware Reference Manual Appendix B Pinouts COM1 Serial Port CableNull Modem COM2 Serial Port Cable to UPSEthernet Port Pinouts STP LAN Cable Appendix C Uninterruptible Power Supply Connect the PSU Module Power CordsSecurStor 16i Installation and Hardware Reference Manual Set the Baud Rate Connect COM2Normal Operational Status UPS MessagesMessage 5 Warning UPS Battery Low 50% UPS Message SummaryThis page is intentionally left blank