Meridian Data 16i manual Host Connection Topologies, Network Topologies, Points of Failure

Page 48

SecurStor16i Installation and Hardware Reference Manual

WARNING!

All cables must be handled with care. Make sure Ethernet cables do not run parallel with power cords. To prevent interference within a rack system, the cable routing path must be carefully planned and they must not be bent.

4.1.2Network Topologies

The iSCSI host ports connect to Ethernet network devices and iSCSI initiators that

comply with the IETF iSCSI standard (RFC 3720). Network connection of the EMD SS16i subsystem’s iSCSI ports is flexible. The use of network connecting devices, subnet, Name Servers, or iSCSI management software can vary from case to case. In the following sections, configuration diagrams will be provided to illustrate the possible uses of the EMD SS16i subsystem in an iSCSI network.

Note that these configurations only recommend but do not intend to impose limitations on the use of subnet settings or networking paths to servers.

4.1.3Points of Failure

The primary concern for configuring host-side topologies is that points of failure should be avoided. It is therefore preferred that the host side be connected to two (2) HBAs and better not the onboard Ethernet. Data flow and access management should therefore be implemented to avoid access contention. MPIO software can be implemented in order to discover a capacity volume through an alternate data link in the event of cabling failure.

4.2 Host Connection Topologies

4.2.1Sample Topology – Direct-Attached, Dual-path Connection

In the configuration shown in Figure 4-1,one (1) EMD SecurStor16i subsystem is connected to two (2) servers. These servers are equipped with iSCSI HBAs and using the subsystem as the shared storage. Multiple arrays or logical partitions can be created and made available separately through different ID/LUNs on the host ports.

Note the following with the configuration as diagrammed below:

1.The RAIDWatch management software accesses a subsystem through its IP address. A management station running RAIDWatch can access the array through the 10/100BaseT management port.

2.Configuration of each port connection into a subnet isolates each iSCSI host link, decreases overheads, and eliminates the impact of link failure.

4-2

Image 48
Contents Installation and Hardware Reference Manual Contact Information CopyrightElectric Shock Warning FCC Class B Radio Frequency Interference StatementCCC Safety Precautions Precautions and InstructionsESD Precautions About This Manual Who should read this manual?Conventions Software and Firmware Updates StepsLists Table of Contents Subsystem Monitoring Appendix a Technical Specifications This page intentionally left blank Page Product Overview Product IntroductionEnclosure Chassis Chassis Overview Physical Dimensions Front Panel OverviewHard Drive Numbering Rear Panel OverviewSubsystem Components Backplane BoardDrive Trays RAID Controller ModuleController Module Interfaces Controller Module Interfaces 2-port versionPower Supply Units Dimm Module5 BBU Cooling Modules PSU ModuleLED Indicators 1 I2C busFirmware FW Audible Alarms Hot-swappable ComponentsHot-swap Capabilities Components Normalized AirflowThis page intentionally left blank Page Chapter Hardware Installation IntroductionSecurStor 16i Installation and Hardware Reference Manual General Installation Procedure Installation Overview Installation Procedure FlowchartUnpacking the Subsystem BBU Installation BBU Module Installation OverviewBBU Warnings and Precautions Installation ProcedureLoosening the BBU Retention Screws Hard Drive Installation Hard Drive Installation PrerequisitesFront View of an Individual Drive Tray Rack/Cabinet Installation Drive Tray Key-lock RotationPage Chapter Subsystem Monitoring Subsystem Monitoring OverviewStatus-indicating LEDs Brief Overview of the LEDsDrive Tray LEDs Controller Module LEDs Name Color StatusRestore Nvram Defaults a Push Button AmberHow to use the button? Ethernet Port LEDsBBU Module LED PSU LEDsCooling Module LEDs Color StatusAudible Alarm Default Threshold ValuesI2C Monitoring Failed DevicesPage Connection Overview CablingHost Connection Topologies Network TopologiesPoints of Failure Sample Topology Direct-Attached, Dual-path ConnectionSample Topology Multiple Servers Each with Dual Connections ISCSI Topology and Host LUN Mapping Power On Sample Topology Connection and Host LUN MappingPower On Procedure Power On EnclosureCheck List Power On Status Check Power SwitchesPower Off Procedure Stop I/O access to the systemMaintenance General Notes on Component ReplacementOverview Replacing Controller Module Components OverviewSubsystem Maintenance and Upgrading Removing the Controller ModuleLoosening the Retention Screws from the BBU Module Replacing the Controller Module Removing the Controller Module from ChassisMemory Module Installation Overview Replacing or Upgrading Memory ModulesSelecting the Memory Modules Dimm Module Installation Removing a Dimm ModuleReplacing a Faulty BBU Fault ConditionsReplacing a Faulty BBU Remove the Retention Screws from BBU Faceplate Install the BBU Module Replacing a Failed PSU Module Printed Text on PSU HandleReplacing the PSU Module PSU Parts Identification10 Removing the PSU Retention Screw Cooling Module Maintenance Remove the cooling fan assembly by the following steps Replacing a Cooling Module13 Removing a Cooling Module Hard Drive Maintenance Overview Replacing a Failed Hard DriveReplacing a Hard Drive 15 Front View of an Individual Drive Tray16 Opening the Drive Tray Front Flap 18 Loosening the Hard Drive Screws Page Appendix a Certifications Configuration ArchitectureDrive Tray Specifications RAID Management SecurStor 16i Installation and Hardware Reference Manual Appendix B Pinouts COM1 Serial Port CableNull Modem COM2 Serial Port Cable to UPSEthernet Port Pinouts STP LAN Cable Appendix C Uninterruptible Power Supply Connect the PSU Module Power CordsSecurStor 16i Installation and Hardware Reference Manual Set the Baud Rate Connect COM2Normal Operational Status UPS MessagesMessage 5 Warning UPS Battery Low 50% UPS Message SummaryThis page is intentionally left blank