Meridian Data 16i manual Appendix a

Page 77

 

 

 

 

 

 

 

 

Appendix A

 

 

 

 

 

 

 

 

Specifications

A.1 Technical Specifications

 

 

 

 

 

 

 

 

 

 

 

Environmental Specifications

 

 

 

 

 

 

 

 

 

 

 

 

Humidity

 

5 to 95% (non condensing – operating and non-operating)

 

 

 

 

 

 

 

 

 

 

 

Temperature

 

Operating: 0º to 40ºC (35ºC if BBU is applied)

 

 

 

Non-operating: -40º to 60ºC

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Altitude

 

Operating: Sea level to 12,000ft

 

 

 

Packaged: Sea level to 40,000ft

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Power Requirements

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Input Voltage

 

100VAC @ 9A

 

 

 

 

240VAC @ 4.5A with PFC (auto-switching)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Frequency

 

47 to 63Hz

 

 

 

 

 

 

 

 

 

 

 

 

Power Consumption

 

530W

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Dimensions

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

With Forearm Handles

 

Without Forearm Handles

 

 

 

 

 

(Not including rear-end

 

 

 

 

 

 

 

protrusions)

 

 

 

 

 

 

 

 

 

 

 

 

Height

 

131mm (5.2 inches)

 

130mm (5.1 inches)

 

 

 

 

 

 

 

 

 

 

Width

 

482.6mm (19 inches)

 

445mm (17.5 inches)

 

 

 

 

 

 

 

 

 

 

Length

 

504.3mm (19.8 inches)

 

488.2mm (19.2 inches)

 

 

 

 

 

 

 

 

 

 

 

 

 

 

System Weight

 

 

 

 

 

 

 

 

 

 

 

 

Net Weight

 

28kg (61.7 pounds)

 

 

 

 

 

 

 

 

 

Gross Weight

 

31kg (68.3 pounds)

 

 

 

 

 

 

 

 

 

 

A-1

Image 77
Contents Installation and Hardware Reference Manual Copyright Contact InformationFCC Class B Radio Frequency Interference Statement Electric Shock WarningCCC ESD Precautions Safety PrecautionsPrecautions and Instructions Conventions About This ManualWho should read this manual? Lists Software and Firmware UpdatesSteps Table of Contents Subsystem Monitoring Appendix a Technical Specifications This page intentionally left blank Page Product Introduction Product OverviewEnclosure Chassis Chassis Overview Front Panel Overview Physical DimensionsRear Panel Overview Hard Drive NumberingBackplane Board Subsystem ComponentsRAID Controller Module Drive TraysController Module Interfaces 2-port version Controller Module Interfaces5 BBU Power Supply UnitsDimm Module PSU Module Cooling Modules1 I2C bus LED IndicatorsHot-swap Capabilities Firmware FW Audible AlarmsHot-swappable Components Normalized Airflow ComponentsThis page intentionally left blank Page Introduction Chapter Hardware InstallationSecurStor 16i Installation and Hardware Reference Manual General Installation Procedure Unpacking the Subsystem Installation OverviewInstallation Procedure Flowchart BBU Module Installation Overview BBU InstallationBBU Warnings and Precautions Installation ProcedureLoosening the BBU Retention Screws Hard Drive Installation Prerequisites Hard Drive InstallationFront View of an Individual Drive Tray Drive Tray Key-lock Rotation Rack/Cabinet InstallationPage Subsystem Monitoring Overview Chapter Subsystem MonitoringDrive Tray LEDs Status-indicating LEDsBrief Overview of the LEDs Name Color Status Controller Module LEDsAmber Restore Nvram Defaults a Push ButtonEthernet Port LEDs How to use the button?PSU LEDs BBU Module LEDColor Status Cooling Module LEDsDefault Threshold Values Audible AlarmFailed Devices I2C MonitoringPage Cabling Connection OverviewNetwork Topologies Host Connection TopologiesPoints of Failure Sample Topology Direct-Attached, Dual-path ConnectionSample Topology Multiple Servers Each with Dual Connections ISCSI Topology and Host LUN Mapping Sample Topology Connection and Host LUN Mapping Power OnCheck List Power On ProcedurePower On Enclosure Power Switches Power On Status CheckStop I/O access to the system Power Off ProcedureOverview MaintenanceGeneral Notes on Component Replacement Overview Replacing Controller Module ComponentsRemoving the Controller Module Subsystem Maintenance and UpgradingLoosening the Retention Screws from the BBU Module Removing the Controller Module from Chassis Replacing the Controller ModuleSelecting the Memory Modules Memory Module Installation OverviewReplacing or Upgrading Memory Modules Removing a Dimm Module Dimm Module InstallationFault Conditions Replacing a Faulty BBUReplacing a Faulty BBU Remove the Retention Screws from BBU Faceplate Install the BBU Module Printed Text on PSU Handle Replacing a Failed PSU ModulePSU Parts Identification Replacing the PSU Module10 Removing the PSU Retention Screw Cooling Module Maintenance Replacing a Cooling Module Remove the cooling fan assembly by the following steps13 Removing a Cooling Module Replacing a Failed Hard Drive Hard Drive Maintenance Overview15 Front View of an Individual Drive Tray Replacing a Hard Drive16 Opening the Drive Tray Front Flap 18 Loosening the Hard Drive Screws Page Appendix a Certifications Architecture ConfigurationDrive Tray Specifications RAID Management SecurStor 16i Installation and Hardware Reference Manual COM1 Serial Port Cable Appendix B PinoutsCOM2 Serial Port Cable to UPS Null ModemEthernet Port Pinouts STP LAN Cable Connect the PSU Module Power Cords Appendix C Uninterruptible Power SupplySet the Baud Rate Connect COM2 SecurStor 16i Installation and Hardware Reference ManualUPS Messages Normal Operational StatusUPS Message Summary Message 5 Warning UPS Battery Low 50%This page is intentionally left blank