Meridian Data 16i manual Drive Trays, RAID Controller Module

Page 18

SecurStor 16i Installation and Hardware Reference Manual

1.2.1 Drive Trays

Figure 1-6: Drive Tray Front View

The SecurStor 16I subsystem comes with sixteen (16) drive trays (see Figure 1-6) designed to accommodate separately purchased, standard 1-inch pitch, 3.5-inch SATA-II disk drives. The drive bays are accessible from the enclosure front panel. Two (2) LEDs on the front bezel indicate the operating statuses. A key-lock on each drive tray secures the hard drive in place, while a release button enables fast retrieval of a hard drive.

WARNING!

Be careful not to warp, twist, or contort the drive tray in any way (e.g., by dropping it or resting heavy objects on it). The drive tray has been customized to fit into the drive bays of the subsystem. If the drive bay superstructure is deformed or altered, the drive trays may not fit into the drive bays.

1.2.2 The RAID Controller Module

The default size for the DDR RAID controller module is 512MB. RAID controller module contains a main circuit board, a preinstalled 512MB capacity or above DDR RAM DIMM module, and the controller module interfaces. The controller module contains no user-serviceable components and should never be removed or opened, except when installing/upgrading the cache memory inside.

WARNING!

Although the RAID controller can be removed, the only time you should touch the controller itself is to install the memory modules. The RAID controller is built of sensitive components and unnecessary tampering can damage the controller.

The heart of the SecurStor 16I RAID controller subsystem is the iSCSI-to- SATA controller board. The controller comes with four (4) GbE Ethernet host ports. The subsystem connects to the host through RJ-45 connectors, while the connectors are also ready to connect to one or more network

1-6

Image 18
Contents Installation and Hardware Reference Manual Contact Information CopyrightElectric Shock Warning FCC Class B Radio Frequency Interference StatementCCC Safety Precautions Precautions and InstructionsESD Precautions About This Manual Who should read this manual?Conventions Software and Firmware Updates StepsLists Table of Contents Subsystem Monitoring Appendix a Technical Specifications This page intentionally left blank Page Product Overview Product IntroductionEnclosure Chassis Chassis Overview Physical Dimensions Front Panel OverviewHard Drive Numbering Rear Panel OverviewSubsystem Components Backplane BoardDrive Trays RAID Controller ModuleController Module Interfaces Controller Module Interfaces 2-port versionPower Supply Units Dimm Module5 BBU Cooling Modules PSU ModuleLED Indicators 1 I2C busFirmware FW Audible Alarms Hot-swappable ComponentsHot-swap Capabilities Components Normalized AirflowThis page intentionally left blank Page Chapter Hardware Installation IntroductionSecurStor 16i Installation and Hardware Reference Manual General Installation Procedure Installation Overview Installation Procedure FlowchartUnpacking the Subsystem BBU Warnings and Precautions BBU InstallationBBU Module Installation Overview Installation ProcedureLoosening the BBU Retention Screws Hard Drive Installation Hard Drive Installation PrerequisitesFront View of an Individual Drive Tray Rack/Cabinet Installation Drive Tray Key-lock RotationPage Chapter Subsystem Monitoring Subsystem Monitoring OverviewStatus-indicating LEDs Brief Overview of the LEDsDrive Tray LEDs Controller Module LEDs Name Color StatusRestore Nvram Defaults a Push Button AmberHow to use the button? Ethernet Port LEDsBBU Module LED PSU LEDsCooling Module LEDs Color StatusAudible Alarm Default Threshold ValuesI2C Monitoring Failed DevicesPage Connection Overview CablingPoints of Failure Host Connection TopologiesNetwork Topologies Sample Topology Direct-Attached, Dual-path ConnectionSample Topology Multiple Servers Each with Dual Connections ISCSI Topology and Host LUN Mapping Power On Sample Topology Connection and Host LUN MappingPower On Procedure Power On EnclosureCheck List Power On Status Check Power SwitchesPower Off Procedure Stop I/O access to the systemMaintenance General Notes on Component ReplacementOverview Replacing Controller Module Components OverviewSubsystem Maintenance and Upgrading Removing the Controller ModuleLoosening the Retention Screws from the BBU Module Replacing the Controller Module Removing the Controller Module from ChassisMemory Module Installation Overview Replacing or Upgrading Memory ModulesSelecting the Memory Modules Dimm Module Installation Removing a Dimm ModuleReplacing a Faulty BBU Fault ConditionsReplacing a Faulty BBU Remove the Retention Screws from BBU Faceplate Install the BBU Module Replacing a Failed PSU Module Printed Text on PSU HandleReplacing the PSU Module PSU Parts Identification10 Removing the PSU Retention Screw Cooling Module Maintenance Remove the cooling fan assembly by the following steps Replacing a Cooling Module13 Removing a Cooling Module Hard Drive Maintenance Overview Replacing a Failed Hard DriveReplacing a Hard Drive 15 Front View of an Individual Drive Tray16 Opening the Drive Tray Front Flap 18 Loosening the Hard Drive Screws Page Appendix a Certifications Configuration ArchitectureDrive Tray Specifications RAID Management SecurStor 16i Installation and Hardware Reference Manual Appendix B Pinouts COM1 Serial Port CableNull Modem COM2 Serial Port Cable to UPSEthernet Port Pinouts STP LAN Cable Appendix C Uninterruptible Power Supply Connect the PSU Module Power CordsSecurStor 16i Installation and Hardware Reference Manual Set the Baud Rate Connect COM2Normal Operational Status UPS MessagesMessage 5 Warning UPS Battery Low 50% UPS Message SummaryThis page is intentionally left blank