Meridian Data 16i manual Subsystem Monitoring

Page 9

SecurStor 16i Installation and Hardware Reference Manual

CHAPTER 3 SUBSYSTEM MONITORING

3.1

SUBSYSTEM MONITORING OVERVIEW

3-1

3.2

STATUS-INDICATINGLEDS

3-2

3.2.1 Brief Overview of the LEDs

3-2

3.2.2

Drive Tray LEDs

3-2

3.2.3

Controller Module LEDs

3-3

Restore NVRAM Defaults – a Push Button

3-4

3.2.4

Ethernet Port LEDs

3-5

3.2.5

BBU Module LED

3-6

3.2.6

PSU LEDs

3-6

3.2.7

Cooling Module LEDs

3-7

3.3

AUDIBLE ALARM

3-8

3.3.1

Default Threshold Values

3-8

3.3.2

Failed Devices

3-9

3.4

I2C MONITORING

3-9

CHAPTER 4 SUBSYSTEM CONNECTION AND OPERATION

4.1

CONNECTION OVERVIEW

4-1

4.1.1

Cabling

4-1

4.1.2

Network Topologies

4-2

4.1.3

Points of Failure

4-2

4.2

HOST CONNECTION TOPOLOGIES

4-2

4.2.1 Sample Topology – Direct-Attached,Dual-path Connection

4-2

4.3

POWER ON

4-5

4.3.1

Check List

4-6

4.3.2

Power On Procedure

4-6

4.3.3

Power On Enclosure

4-6

4.3.4 Power On Status Check

4-7

4.4

POWER OFF PROCEDURE

4-8

CHAPTER 5 SUBSYSTEM MAINTENANCE AND UPGRADING

5.1

OVERVIEW

5-1

5.1.1

Maintenance

5-1

5.1.2 General Notes on Component Replacement

5-1

5.2

REPLACING CONTROLLER MODULE COMPONENTS

5-2

5.2.1

Overview

5-2

5.2.2 Notes on Controller Module Maintenance

5-3

5.2.3 Removing the Controller Module

5-3

5.2.4 Replacing the Controller Module

5-5

5.3

REPLACING OR UPGRADING MEMORY MODULES

5-6

5.3.1 Memory Module Installation Overview

5-6

5.3.2 Selecting the Memory Modules

5-6

5.3.3

DIMM Module Installation

5-7

5.4

REPLACING A FAULTY BBU

5-8

5.4.1 BBU Warnings and Precautions

5-9

5.4.2 Replacing a Faulty BBU

5-9

5.5

REPLACING A FAILED PSU MODULE

5-12

5.5.1 Notes on PSU Module Maintenance

5-12

5.5.2 Replacing the PSU Module

5-13

5.6

COOLING MODULE MAINTENANCE

5-15

5.6.1 Notes on Cooling Module Maintenance

5-15

5.6.2 Replacing a Cooling Module

5-16

5.7

REPLACING A FAILED HARD DRIVE

5-18

5.7.1 Hard Drive Maintenance Overview

5-18

5.7.2 Replacing a Hard Drive

5-19

ix

Image 9
Contents Installation and Hardware Reference Manual Copyright Contact InformationFCC Class B Radio Frequency Interference Statement Electric Shock WarningCCC Safety Precautions Precautions and InstructionsESD Precautions About This Manual Who should read this manual?Conventions Software and Firmware Updates StepsLists Table of Contents Subsystem Monitoring Appendix a Technical Specifications This page intentionally left blank Page Product Introduction Product OverviewEnclosure Chassis Chassis Overview Front Panel Overview Physical DimensionsRear Panel Overview Hard Drive NumberingBackplane Board Subsystem ComponentsRAID Controller Module Drive TraysController Module Interfaces 2-port version Controller Module InterfacesPower Supply Units Dimm Module5 BBU PSU Module Cooling Modules1 I2C bus LED IndicatorsFirmware FW Audible Alarms Hot-swappable ComponentsHot-swap Capabilities Normalized Airflow ComponentsThis page intentionally left blank Page Introduction Chapter Hardware InstallationSecurStor 16i Installation and Hardware Reference Manual General Installation Procedure Installation Overview Installation Procedure FlowchartUnpacking the Subsystem BBU Module Installation Overview BBU InstallationBBU Warnings and Precautions Installation ProcedureLoosening the BBU Retention Screws Hard Drive Installation Prerequisites Hard Drive InstallationFront View of an Individual Drive Tray Drive Tray Key-lock Rotation Rack/Cabinet InstallationPage Subsystem Monitoring Overview Chapter Subsystem MonitoringStatus-indicating LEDs Brief Overview of the LEDsDrive Tray LEDs Name Color Status Controller Module LEDsAmber Restore Nvram Defaults a Push ButtonEthernet Port LEDs How to use the button?PSU LEDs BBU Module LEDColor Status Cooling Module LEDsDefault Threshold Values Audible AlarmFailed Devices I2C MonitoringPage Cabling Connection OverviewNetwork Topologies Host Connection TopologiesPoints of Failure Sample Topology Direct-Attached, Dual-path ConnectionSample Topology Multiple Servers Each with Dual Connections ISCSI Topology and Host LUN Mapping Sample Topology Connection and Host LUN Mapping Power OnPower On Procedure Power On EnclosureCheck List Power Switches Power On Status CheckStop I/O access to the system Power Off ProcedureMaintenance General Notes on Component ReplacementOverview Overview Replacing Controller Module ComponentsRemoving the Controller Module Subsystem Maintenance and UpgradingLoosening the Retention Screws from the BBU Module Removing the Controller Module from Chassis Replacing the Controller ModuleMemory Module Installation Overview Replacing or Upgrading Memory ModulesSelecting the Memory Modules Removing a Dimm Module Dimm Module InstallationFault Conditions Replacing a Faulty BBUReplacing a Faulty BBU Remove the Retention Screws from BBU Faceplate Install the BBU Module Printed Text on PSU Handle Replacing a Failed PSU ModulePSU Parts Identification Replacing the PSU Module10 Removing the PSU Retention Screw Cooling Module Maintenance Replacing a Cooling Module Remove the cooling fan assembly by the following steps13 Removing a Cooling Module Replacing a Failed Hard Drive Hard Drive Maintenance Overview15 Front View of an Individual Drive Tray Replacing a Hard Drive16 Opening the Drive Tray Front Flap 18 Loosening the Hard Drive Screws Page Appendix a Certifications Architecture ConfigurationDrive Tray Specifications RAID Management SecurStor 16i Installation and Hardware Reference Manual COM1 Serial Port Cable Appendix B PinoutsCOM2 Serial Port Cable to UPS Null ModemEthernet Port Pinouts STP LAN Cable Connect the PSU Module Power Cords Appendix C Uninterruptible Power SupplySet the Baud Rate Connect COM2 SecurStor 16i Installation and Hardware Reference ManualUPS Messages Normal Operational StatusUPS Message Summary Message 5 Warning UPS Battery Low 50%This page is intentionally left blank