Meridian Data 16i manual Cooling Modules, PSU Module

Page 21

Chapter 1 Introduction

NOTE:

Hot-swapping the PSU also removes the cooling module at the lower slot.

As shown in Figure 1-9, each PSU comes with a power socket and a power switch to turn the subsystem on and off. Two (2) embedded cooling fans provide sufficient airflow. A single LED indicates the PSU status. When a power supply failure occurs, the red LED lights come on. A rejection handle at the rear of the PSU is especially designed to help properly install or remove the module.

A screw hole on the ejection handle helps secure the PSU to the chassis.

Figure 1-9: PSU Module

Please refer to Appendix B for the technical information of the PSUs.

1.2.7 Cooling Modules

Two cooling modules are implemented within the rear sections of PSU modules. (see Figure 1-10.) The cooling fans operate at two (2) fan speed levels. When the subsystem operates normally, the cooling fans operate at the lower speed. If a major component fails or when one of the temperature thresholds is violated, the cooling fans automatically raise its rotation speed.

More technical information can be found in Appendix B.

1-9

Image 21
Contents Installation and Hardware Reference Manual Copyright Contact InformationFCC Class B Radio Frequency Interference Statement Electric Shock WarningCCC Safety Precautions Precautions and InstructionsESD Precautions About This Manual Who should read this manual?Conventions Software and Firmware Updates StepsLists Table of Contents Subsystem Monitoring Appendix a Technical Specifications This page intentionally left blank Page Product Introduction Product OverviewEnclosure Chassis Chassis Overview Front Panel Overview Physical DimensionsRear Panel Overview Hard Drive NumberingBackplane Board Subsystem ComponentsRAID Controller Module Drive TraysController Module Interfaces 2-port version Controller Module InterfacesPower Supply Units Dimm Module5 BBU PSU Module Cooling Modules1 I2C bus LED IndicatorsFirmware FW Audible Alarms Hot-swappable ComponentsHot-swap Capabilities Normalized Airflow ComponentsThis page intentionally left blank Page Introduction Chapter Hardware InstallationSecurStor 16i Installation and Hardware Reference Manual General Installation Procedure Installation Overview Installation Procedure FlowchartUnpacking the Subsystem BBU Module Installation Overview BBU InstallationBBU Warnings and Precautions Installation ProcedureLoosening the BBU Retention Screws Hard Drive Installation Prerequisites Hard Drive InstallationFront View of an Individual Drive Tray Drive Tray Key-lock Rotation Rack/Cabinet InstallationPage Subsystem Monitoring Overview Chapter Subsystem MonitoringStatus-indicating LEDs Brief Overview of the LEDsDrive Tray LEDs Name Color Status Controller Module LEDsAmber Restore Nvram Defaults a Push ButtonEthernet Port LEDs How to use the button?PSU LEDs BBU Module LEDColor Status Cooling Module LEDsDefault Threshold Values Audible AlarmFailed Devices I2C MonitoringPage Cabling Connection OverviewNetwork Topologies Host Connection TopologiesPoints of Failure Sample Topology Direct-Attached, Dual-path ConnectionSample Topology Multiple Servers Each with Dual Connections ISCSI Topology and Host LUN Mapping Sample Topology Connection and Host LUN Mapping Power OnPower On Procedure Power On EnclosureCheck List Power Switches Power On Status CheckStop I/O access to the system Power Off ProcedureMaintenance General Notes on Component ReplacementOverview Overview Replacing Controller Module ComponentsRemoving the Controller Module Subsystem Maintenance and UpgradingLoosening the Retention Screws from the BBU Module Removing the Controller Module from Chassis Replacing the Controller ModuleMemory Module Installation Overview Replacing or Upgrading Memory ModulesSelecting the Memory Modules Removing a Dimm Module Dimm Module InstallationFault Conditions Replacing a Faulty BBUReplacing a Faulty BBU Remove the Retention Screws from BBU Faceplate Install the BBU Module Printed Text on PSU Handle Replacing a Failed PSU ModulePSU Parts Identification Replacing the PSU Module10 Removing the PSU Retention Screw Cooling Module Maintenance Replacing a Cooling Module Remove the cooling fan assembly by the following steps13 Removing a Cooling Module Replacing a Failed Hard Drive Hard Drive Maintenance Overview15 Front View of an Individual Drive Tray Replacing a Hard Drive16 Opening the Drive Tray Front Flap 18 Loosening the Hard Drive Screws Page Appendix a Certifications Architecture ConfigurationDrive Tray Specifications RAID Management SecurStor 16i Installation and Hardware Reference Manual COM1 Serial Port Cable Appendix B PinoutsCOM2 Serial Port Cable to UPS Null ModemEthernet Port Pinouts STP LAN Cable Connect the PSU Module Power Cords Appendix C Uninterruptible Power SupplySet the Baud Rate Connect COM2 SecurStor 16i Installation and Hardware Reference ManualUPS Messages Normal Operational StatusUPS Message Summary Message 5 Warning UPS Battery Low 50%This page is intentionally left blank