CONTROLS AND INDICATORS

FRONT PANEL (LCD Units)

Primary Power Switch: Press and release the

ON/OFF button to turn the unit ON or OFF.

Normal Mode Icon: This icon will illuminate when the utility power is within safe operating range.

Battery Mode Icon: This icon will illuminate when the Utility power is outside safe operating range and the unit is operating in the battery mode.

Bypass Mode Icon: This icon will illuminate when the unit is in bypass mode and you do not have battery backup protection.

Unit Fault Icon: The Fault icon illuminates when the UPS has detected an internal fault. (see section 5)

Unit Fault Icon: This icon and error code will illuminate when the self diagnostics are able to determine the problem.

Unit Charger Icon: This icon will illuminate when the unit is charging the batteries.

Unit Overload Icon: This icon will illuminate when the unit load has exceed the rating of the UPS. The UPS will transfer to bypass mode if the overload is not removed.

Estimated Time Remaining icons: These combination of LCD icons will illuminate when selected and the UPS is operating in the battery mode. The first time icon will appear as ">" if the estimated time remaining is greater than ten (10) minutes. This symbol will turn off when the estimated time remaining is less than 10 minutes and the remaining time will appear in the display.

Unit Audible Alarm Icon: This alarm will illuminate when audible alarm is silenced.

4

Image 5
Contents MCP-E Series Table of Contents Introduction Important Safety InstructionsPara Systems Life Support Policy Front Panel LCD Units Controls and IndicatorsEnglish Installation Placement InstallationMCP 5000iE and MCP 7000iE Installation Service Personnel only Installation of the mounting tray and the stablizing feet English Connecting Your Equipment Connecting to AN AC SourceComputer Interface Connection Optional Network Surge Protection Connection OptionalTurning the Unit ON/OFF OperationEnglish On Battery AlarmsEnglish Diagnostic codes for 700VA and 1KVA TroubleshootingEnglish Diagnostic Error Codes for 2KVA, 3KVA, 5KVA, 7KVA units Replacing the Battery Replacing the BatteryCSB Battery Replacement Procedure for Tower Model Battery Replacement Procedure for Rack Mount Models If the UPS Requires Service Obtaining ServiceInput Non-Battery Operation SpecificationsFunction Factory Default User Choices Description Configurable Parameters and SettingsCustomized Output Receptacle Panels Limited Product Warranty Limited Product WarrantyDeclaration of Conformity 302