INSTALLATION • OEM650/OEM650X
Quick Test: OEM650 with Separate Indexer
1.Complete steps 1- 6 from the OEM650 Quick Test, but do not remove jumper #11 (Auto Test Function).
2.To connect a Compumotor indexer to the OEM650’s
To connect a
3.Apply power. The OEM’s green power LED should be on. If the red FAULT LED is on, consult Chapter 5, Troubleshooting.
This test assumes that your indexer’s motor resolution is set to 25,000 steps/rev. This is the default motor resolution setting for the OEM650.
4.Using the indexer, send step pulses to the drive that will rotate the motor one CW revolution (25,000 step pulses) at 1 rps (25,000 steps per second).
5.Using the indexer, send step pulses to the drive that will rotate the motor one CCW revolution at 1 rps. The drive's default direction is CCW (i.e., if the the direction input is not activated, the motor will rotate
WARNING
Never connect or disconnect any component to or from the drive with power
applied. System damage or personal injury may occur.
6.After verifying that the motor moves CW and CCW, turn off power.
❐ Disconnect cables and resistor.
10