Powermatic 2700 manual Extension Cords, Voltage Conversion 3 Phase Shaper only

Page 10

This machine must be grounded. Grounding provides a path of least resistance to help divert current away from the operator in case of electrical malfunction.

Make sure the voltage of your power supply matches the specifications on the motor plate of the machine.

The PM2700 Shaper should be connected to a dedicated circuit, and protected by a circuit breaker or time delay fuse, with minimum amp ratings as shown in Table 1. Local codes take precedence over recommendations.

Model

Recommended circuit*

 

 

1280100C (3HP 1PH 230V)

15 Amp

 

 

1280101C (5HP 1PH 230V)

60 Amp

 

 

1280102C (5HP 3PH 230V)

30 Amp

 

 

1280102C (5HP 3PH 460V)

15 Amp

*subject to local codes

Table 1

Voltage Conversion (3 Phase Shaper only)

On the 3 phase model, to convert from 230V to 460V, replace the 230V switch with the 460V switch (not included, order part no. PM2700-114C), and re-wire the incoming leads to the motor as shown on the diagram inside the cover of the motor junction box. A similar diagram is also included in the back of this manual. (Figure 3 shows a summary of the lead changes for 230V to 460V conversion.)

Extension Cords

The use of extension cords is discouraged. Try to position equipment within reach of the power source. If an extension cord becomes necessary, make sure the cord rating is suitable for the amperage listed on the machine's motor plate. An undersize cord will cause a drop in line voltage resulting in loss of power and overheating.

The chart in Table 2 shows the correct size cord to use based on cord length and motor plate amp rating. If in doubt, use the next heavier gauge. The smaller the gauge number, the heavier the cord.

Figure 3

 

 

Extension Cord Length *

 

 

 

 

 

 

 

 

Amps

25

50

75

100

150

200

feet

feet

feet

feet

feet

feet

 

 

 

 

 

 

 

< 5

16

16

16

14

12

12

 

 

 

 

 

 

 

5 to 8

16

16

14

12

10

NR

 

 

 

 

 

 

 

8 to 12

14

14

12

10

NR

NR

 

 

 

 

 

 

 

12 to 15

12

12

10

10

NR

NR

 

 

 

 

 

 

 

15 to 20

10

10

10

NR

NR

NR

 

 

 

 

 

 

 

21 to 30

10

NR

NR

NR

NR

NR

 

 

 

 

 

 

 

*based on limiting the line voltage drop to 5V at 150% of the rated amperes.

NR: Not Recommended.

Table 2

10

Image 10
Contents Model 2700 Shaper Warranty and Service More InformationTable of Contents Page Page Figure a Introduction Specifications Spindle Capacity Under NutShipping Contents InstallingUnpacking Mounting the Fence AssemblyElectrical Connections General InformationVoltage Conversion 3 Phase Shaper only Extension CordsFence Assembly Movement AdjustmentsHandwheel Adjustments Coplanar Alignment Coplanar AdjustmentVerifying that fences are coplanar Ram Dial Calibration Loosen the outfeed fence lock knob BFeatherboard Hold-downs Spindle Gib AdjustmentLoosen lock handles C and lock knobs D Installing the Spindle Assembly Spindle Assembly InstallationSpindle Assembly Removal Locking the ArborInstalling the Shaper Cutter Shaper Cutter InstallationRouter Collet Optional Installation Locking the SpindleChanging Cutter Speed Belt ReplacementDrive Belt Tension Precision Miter Gauge Loosen lock handle aStart/Stop Safety KeyOperating Controls Digital ReadoutOverview Safety DevicesOperations Grain Direction ConsiderationsUsing the Fence Depth of Cut DimensionStraight Edge Shaping Shaping All Sides Edge ShapingEnd Shaping On-Edge ShapingStraight Line Bevel Shaping Contour Edge Shaping With Collar BearingShaping With Collars Position of CollarsStarting Pin Arcs and Circles Enclosed Edge ShapingTemplates Securing the TemplateStacked Cutters Special CutsSash and Door Shaping Tongued Joint Butt JointsGlue Butt Joint Drop Leaf JointTenoning Troubleshooting See also Unsatisfactory CutsOrdering Replacement Parts Optional AccessoriesParts Table Parts List Index No Description Size QtyTable Assembly Drawing Fence Parts List Index No. Part No Description Size QtyFence Assembly Drawing Frame and Motor Parts List Frame and Motor Assembly Drawing Elevator Parts List Elevator Assembly Drawing Caster Assembly Parts List Caster Assembly Drawing Spindle Assembly Parts List Spindle Assembly Drawing Spindle 30mm Spindle 4 SpindleCabinet and Base Parts List PM2700-454 Motor Cable 3HP, 1Ph Cabinet and Base Wiring 3HP/5HP Diagrams 1PhaseMagnetic Switch 5HP, 230V, 3Phase5HP, 460V, 3Phase New Sanford Road LaVergne, TN Phone