Powermatic 2700 manual Ram Dial Calibration, Loosen the outfeed fence lock knob B

Page 13

Ram Dial Calibration

The guard and spindle should be removed. Referring to Figure 12:

1.Loosen the infeed fence lock knob (E), then turn the infeed ram dial (D) counterclockwise to bring the infeed fence (F) back all the way until the limiter setscrew (P) touches the head casting (M). Then retighten the lock knob (E).

2.If necessary, loosen two setscrews on the infeed ram dial (D) with a 2mm hex wrench and align the zero on the dial with the indicator mark. Then tighten the setscrews.

3.Next, loosen the outfeed fence lock knob (B) and turn the outfeed ram dial (A) counter- clockwise to bring the outfeed fence (C) all the way back.

4.Place a straightedge (G) on the table against both fences.

If both fences are flush with the straightedge (K) and the outfeed ram dial (A) indicates zero, no further action is necessary.

If alignment is necessary (J):

5.Slide the outfeed fence (C) aside to reveal the limiting setscrew (P) on the fence casting (N).

6.Loosen the hex locking nut (O) with a 10mm wrench and back out the limiting setscrew (P) with a 3mm hex wrench to permit a sufficient backward and forward adjustment range for the outfeed fence (C).

7.Slide the outfeed fence (C) back onto the casting and secure.

8.Loosen the outfeed fence lock knob (B).

9.While maintaining pressure (H) on the straightedge (G) against the fences (C, F), adjust the outfeed ram dial (A) until both fences are in-line (K).

After proper alignment is made:

10.Slide the outfeed fence (C) aside again.

11.Turn the limiting setscrew (P) in (turn cw) until it comes in contact with the head casting (M)

12.Tighten the hex locking nut (O) with a 10mm wrench while maintaining the setscrew position with the 3mm hex wrench.

13.Replace the outfeed fence and secure.

14.Loosen the two set-screws(2mm hex wrench) on the outfeed ram dial (A) and align the zero on the dial with the indicator mark. Then tighten the setscrews.

Infeed side fence casting

-- Outfeed side is mirror image

Figure 12

13

Image 13
Contents Model 2700 Shaper More Information Warranty and ServiceTable of Contents Page Page Figure a Spindle Capacity Under Nut Introduction SpecificationsShipping Contents InstallingUnpacking Electrical Connections AssemblyMounting the Fence General InformationExtension Cords Voltage Conversion 3 Phase Shaper onlyFence Assembly Movement AdjustmentsHandwheel Adjustments Coplanar Alignment Coplanar AdjustmentVerifying that fences are coplanar Loosen the outfeed fence lock knob B Ram Dial CalibrationFeatherboard Hold-downs Spindle Gib AdjustmentLoosen lock handles C and lock knobs D Spindle Assembly Removal Spindle Assembly InstallationInstalling the Spindle Assembly Locking the ArborRouter Collet Optional Installation Shaper Cutter InstallationInstalling the Shaper Cutter Locking the SpindleChanging Cutter Speed Belt ReplacementDrive Belt Tension Loosen lock handle a Precision Miter GaugeOperating Controls Safety KeyStart/Stop Digital ReadoutOperations Safety DevicesOverview Grain Direction ConsiderationsUsing the Fence Depth of Cut DimensionStraight Edge Shaping End Shaping Edge ShapingShaping All Sides On-Edge ShapingContour Edge Shaping With Collar Bearing Straight Line Bevel ShapingPosition of Collars Shaping With CollarsStarting Pin Enclosed Edge Shaping Arcs and CirclesSecuring the Template TemplatesStacked Cutters Special CutsSash and Door Shaping Glue Butt Joint Butt JointsTongued Joint Drop Leaf JointTenoning See also Unsatisfactory Cuts TroubleshootingOrdering Replacement Parts Optional AccessoriesParts Index No Description Size Qty Table Parts ListTable Assembly Drawing Index No. Part No Description Size Qty Fence Parts ListFence Assembly Drawing Frame and Motor Parts List Frame and Motor Assembly Drawing Elevator Parts List Elevator Assembly Drawing Caster Assembly Parts List Caster Assembly Drawing Spindle Assembly Parts List Spindle 30mm Spindle 4 Spindle Spindle Assembly DrawingCabinet and Base Parts List PM2700-454 Motor Cable 3HP, 1Ph Cabinet and Base Diagrams 1Phase Wiring 3HP/5HP5HP, 230V, 3Phase Magnetic Switch5HP, 460V, 3Phase New Sanford Road LaVergne, TN Phone