Opticon LMD 1135 user manual Section Scanner Labeling, IEC 825-1 Class 1 Laser Device

Page 19

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Section 6

Scanner Labeling

IEC 825-1 Class 1 Laser Device

The LMD 1135 has been examined and found to be a Class 1 Laser Device according to the relevant requirements of IEC 825-1 and corresponding EN 60825-1 (1993-11) including amendment 1 (1997-09) and amendment 2 (2001-01).

This scanner also complies with Center for Devices and Radiological Health (CDRH) 21 CFR 1040.10 and 1040.11 except for deviations pursuant to Laser Notice No. 50 dated July 26, 2001.

The LMD 1135 scanner use a low-power visible laser. As with any very bright light source, such as the sun, you should avoid staring into the light beam. Momentary exposure to an IEC 825-1 Class 1 laser is not known to be harmful.

A manufacturer’s label, as shown below, indicating the manufacturer, product model, ordering number, serial number, laser class, CE mark and place of manufacture is affixed to each scanner.

Section 7

Scanner Servicing and Maintenance

CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous laser light exposure.

The LMD 1135 scanner contains no user adjustable or serviceable parts in the interior of the scanner. All product service must be performed by the Opticon Service Department in Orangeburg, NY. Opening the scanner will void the warranty and could expose the operator to laser light.

The LMD 1135 is warranted for 1 year including parts and workmanship. If you need warranty or out-of- warranty repair, first call 1-800-636-0090to obtain a Returned Material Authorization (RMA) number. You will be provided a number and shipping instructions.

There is no scheduled maintenance required for the LMD 1135. The scanner can be cleaned using a water dampened, lint free or lens cloth. Be careful to avoid excessive moisture that would penetrate the housing or obscure the window. While use of cleaning fluids other than water are not recommended, a neutral detergent or ethanol would be preferred if necessary. Do not use bleach at full or diluted strength as damage to the painted case and/or window may result.

Page 15

Image 19
Contents User’s Manual Manual No -ULPNR102-01 March OSE Command SetPage Contents Introduction and Getting Started Technical SpecificationsConfiguring the Scanner Scanner Servicing and MaintenanceSection Introduction and Getting Started Quick Start-Up ProcedureProduct Overview Page Physical Specifications Section Technical SpecificationsOptical Specifications Avoid specular reflection in the dead zone +/- 8 degrees JAN 13 R = 30 mm 1.2 or Electrical SpecificationsRS232 Transmit / Receive Character Format RS232 Communications SpecificationsConnector Pin-outs RS232 Signal LevelModel Environmental SpecificationsPin No Signal Ordering InformationDepth-of-Field Section Positioning the Scanner for Optimum PerformanceAchieving Optimum Performance Distance to the Bar CodeDistance Max From Window Width Avoiding Specular ReflectionQuality Bar Code Labels Measuring Scanner PerformanceTips for Insuring Highest Data Integrity Application Notes Tips for Achieving High ThroughputTips for Verifying the Presence of a Bar Code Parameter Factory Default Setting Section Configuring the ScannerProgramming Menus & Commands Default SettingsModified and/or Customized Scanners Section Application Engineering SupportTechnical Assistance and Support Common Causes of Poor PerformanceSection Scanner Labeling Section Scanner Servicing and MaintenanceIEC 825-1 Class 1 Laser Device Appendices Appendix a ESC Computer Command CRWhat if you make a mistake? Reset All Defaults U2 Command U2Options for EAN-8 & EAN-13 Global DefaultsSymbology Selection Options for UPCOptions for Code Prefix/Suffix of Alpha Characters Select Symbology forPrefix/Suffix Prefix/Suffix of Numeric CharactersHandshaking Setting the Trigger & Auto-TriggerSelecting the Read Mode Parallel Read ModeQuiet Zone Options Scanner Timeout Trigger EnabledXmit Error Trigger Enabled Mode only ModeAppendix C Including prefix/suffix Global Default & Scanner ConfigurationsCommand Description ComputerBar Code Symbology SelectionDescription Command SymbologiesOnly EAN 13/8 +2 START/END Add/Activate Specific Bar Code SymbologiesAdd/Activate Specific Bar Code Symbologies Delete/Deactivate Specific Bar Code SymbologiesDisable all symbologies Options for UPC Bar Code Command DescriptionOptions for EAN-8 & EAN-13 Options for Code 39 & IT Pharmaceutical IT Pharmaceutical, enable Transmit of leading a Options for Codabar NW-7 Codabar NW-7 Format 5 Format Standard and Interleaved Options for Interleaved & Industrial 2Number of digits 15 total Options for IataString format Meaning of AcronymOptions for Code-93 Options for Code-128 / EAN-128Fixing the Number of Digits Disable fixed length allCreating a Prefix and/or Suffix UPC-E +2 or +5 Setting Prefixes Identifying the SymbologyMSI/Plessey Setting Suffixes Identifying the Symbology Bar Code Command Description Direct Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case Direct Input of Control Characters ETBSUB Direct Input Characters Misc Bar Code Command Description START/END Code Identification & Characters/Digits TransmittedCommunication Parameters Communication Parameters Terminal HandshakingMs intercharacter delay Buzzer Operation Disable buzzerPositive & Negative Bar Codes Setting the Trigger & Auto-Trigger FunctionsTrigger Function Enabled S8 Trigger Function Disabled S7 Selecting the Read ModeAdd-on Wait Mode Applies to UPC/EAN only Parallel Read ModeParallel labels only Scanner Timeout Trigger Enabled Mode only Multiple Read Reset Time Quiet Zone Options Redundant Decoding Error Messages No decode / no label Transmitting Error Indications Trigger Enabled onlyGood Read LED Operation Appendix D Appendix E