Opticon LMD 1135 Select Symbology for, Prefix/Suffix of Numeric Characters, Transmission

Page 25

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Prefix

Suffix

Select Symbology for

 

 

Prefix/Suffix

RY

RZ

All codes

N1

N6

UPC-A

M0

O0

UPC-A +2 or +5

N2

N7

UPC-E

M1

O1

UPC-E +2 or +5

N3

N8

EAN13

M2

O2

EAN-13 +2 or +5

N4

N9

EAN-8

M3

O3

EAN-8 +2or +5

M4

O4

Code 39

M5

O5

Codabar (NW-7)

M6

O6

Industrial 2 of 5

M7

O7

Interleaved 2 of 5

M8

O8

Code 93

M9

O9

Code 128

I8

I9

IATA

N0

N5

MSI/Plessey

MB

OB

SCode

L8

L9

Telepen

 

 

 

Prefix/Suffix of Numeric Characters

Q0

0

 

thru

thru

 

Q9

9

 

 

Prefix/Suffix of Alpha Characters

0A

A

 

thru

thru

 

0Z

Z

 

 

Prefix/Suffix of Control Characters

1B

STX

1C

ETX

1M

Carriage Return

1J

Line Feed

 

 

 

Code ID & Character Length

 

Transmission

$2

Code identification

$3

Code length 2 digits

$6

Code length 6 digits

 

 

 

Communications Parameters

K0

 

150 baud

K1

 

300 baud

K2

 

600 baud

K3

1,200 baud

K4

2,400 baud

K5

4,800 baud

K6

9,600 baud

K7

19,200 baud

K8

38,400 baud

L0

7

Data Bits

L1

8

Data Bits

L2

Parity = None

L3

Parity = Even

L4

Parity = Odd

L5

1

Stop bit

L6

2

Stop bits

Page 21

Image 25
Contents User’s Manual Manual No -ULPNR102-01 March OSE Command SetPage Contents Configuring the Scanner Technical SpecificationsScanner Servicing and Maintenance Introduction and Getting StartedSection Introduction and Getting Started Quick Start-Up ProcedureProduct Overview Page Physical Specifications Section Technical SpecificationsOptical Specifications Avoid specular reflection in the dead zone +/- 8 degrees JAN 13 R = 30 mm 1.2 or Electrical SpecificationsConnector Pin-outs RS232 Communications SpecificationsRS232 Signal Level RS232 Transmit / Receive Character FormatPin No Signal Environmental SpecificationsOrdering Information ModelAchieving Optimum Performance Section Positioning the Scanner for Optimum PerformanceDistance to the Bar Code Depth-of-FieldDistance Max From Window Width Avoiding Specular ReflectionQuality Bar Code Labels Measuring Scanner PerformanceTips for Insuring Highest Data Integrity Application Notes Tips for Achieving High ThroughputTips for Verifying the Presence of a Bar Code Programming Menus & Commands Section Configuring the ScannerDefault Settings Parameter Factory Default SettingTechnical Assistance and Support Section Application Engineering SupportCommon Causes of Poor Performance Modified and/or Customized ScannersSection Scanner Labeling Section Scanner Servicing and MaintenanceIEC 825-1 Class 1 Laser Device Appendices Appendix a ESC Computer Command CRWhat if you make a mistake? Reset All Defaults U2 Command U2Symbology Selection Global DefaultsOptions for UPC Options for EAN-8 & EAN-13Options for Code Prefix/Suffix Select Symbology forPrefix/Suffix of Numeric Characters Prefix/Suffix of Alpha CharactersSelecting the Read Mode Setting the Trigger & Auto-TriggerParallel Read Mode HandshakingXmit Error Trigger Enabled Mode only Scanner Timeout Trigger EnabledMode Quiet Zone OptionsAppendix C Command Description Global Default & Scanner ConfigurationsComputer Including prefix/suffixDescription Command Symbology SelectionSymbologies Bar CodeOnly EAN 13/8 +2 START/END Add/Activate Specific Bar Code SymbologiesAdd/Activate Specific Bar Code Symbologies Delete/Deactivate Specific Bar Code SymbologiesDisable all symbologies Options for UPC Bar Code Command DescriptionOptions for EAN-8 & EAN-13 Options for Code 39 & IT Pharmaceutical IT Pharmaceutical, enable Transmit of leading a Options for Codabar NW-7 Codabar NW-7 Format 5 Format Standard and Interleaved Options for Interleaved & Industrial 2String format Options for IataMeaning of Acronym Number of digits 15 totalOptions for Code-93 Options for Code-128 / EAN-128Fixing the Number of Digits Disable fixed length allCreating a Prefix and/or Suffix UPC-E +2 or +5 Setting Prefixes Identifying the SymbologyMSI/Plessey Setting Suffixes Identifying the Symbology Bar Code Command Description Direct Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case Direct Input of Control Characters ETBSUB Direct Input Characters Misc Bar Code Command Description START/END Code Identification & Characters/Digits TransmittedCommunication Parameters Communication Parameters Terminal HandshakingMs intercharacter delay Buzzer Operation Disable buzzerPositive & Negative Bar Codes Setting the Trigger & Auto-Trigger FunctionsTrigger Function Enabled S8 Trigger Function Disabled S7 Selecting the Read ModeAdd-on Wait Mode Applies to UPC/EAN only Parallel Read ModeParallel labels only Scanner Timeout Trigger Enabled Mode only Multiple Read Reset Time Quiet Zone Options Redundant Decoding Error Messages No decode / no label Transmitting Error Indications Trigger Enabled onlyGood Read LED Operation Appendix D Appendix E