Opticon LMD 1135 Positive & Negative Bar Codes, Setting the Trigger & Auto-Trigger Functions

Page 62

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

26. Positive & Negative Bar Codes

 

Computer

Function

 

Bar Code

 

Command

/Description

 

Command

 

(ZZ)

START/END

 

[[ ￿

 

Programming Menu

 

 

 

 

 

 

 

V2

Positive bar code only

 

W3 ￿

 

(black bars/white spaces)

 

 

 

 

 

 

 

V3

Negative bar codes

 

W! ￿

 

 

 

 

 

 

 

 

 

 

V4

Both positive & negative bar

 

W5 ￿

 

code

 

 

 

 

 

 

27. Setting the Trigger & Auto-Trigger Functions

 

 

 

 

 

 

Computer

Function

 

Bar Code

 

Command

/Description

 

Command

 

(ZZ)

START/END

 

[[ ￿

 

Programming Menu

 

 

 

 

 

 

 

S7

Disable the trigger function

 

T8 ￿

 

/ laser is ON continuously

 

 

 

 

 

 

 

S8

Enable the trigger function /laser

 

T9 ￿

 

is OFF until trigger is activated or

 

 

 

“pulled”

 

 

 

 

 

 

 

 

+F

Disable Auto-trigger

 

,G ￿

 

 

 

 

 

 

 

 

 

 

+I

Enable Auto-trigger

 

,J ￿

 

 

 

 

 

 

 

 

 

 

Z

Activate the trigger; turns on the

 

Use as

 

laser

 

Computer Command

 

 

 

 

 

 

 

 

￿

%￿

￿

￿

￿

%￿

%

The Trigger function is enabled in the default setting. This means that the laser is “OFF” until triggered by command or via the Auto-Trigger which is also enabled in the default setting. For some applications, you may wish the laser to operate continuously, although this is not recommended. This can be done by disabling the Trigger function using the S7 command. Once in the “Trigger Disabled” mode, the laser is on continuously.

The software trigger is actuated by downloading and <ESC> Z <CR> computer command from the host. (See Scanner Timeout to establish the length of time the scanning light remains ON after the trigger is activated.) A hardware trigger is not available with this scanner.

Page 58

Image 62
Contents Manual No -ULPNR102-01 March OSE Command Set User’s ManualPage Contents Scanner Servicing and Maintenance Technical SpecificationsConfiguring the Scanner Introduction and Getting StartedProduct Overview Quick Start-Up ProcedureSection Introduction and Getting Started Page Optical Specifications Section Technical SpecificationsPhysical Specifications Avoid specular reflection in the dead zone +/- 8 degrees Electrical Specifications JAN 13 R = 30 mm 1.2 orRS232 Signal Level RS232 Communications SpecificationsConnector Pin-outs RS232 Transmit / Receive Character FormatOrdering Information Environmental SpecificationsPin No Signal ModelDistance to the Bar Code Section Positioning the Scanner for Optimum PerformanceAchieving Optimum Performance Depth-of-FieldAvoiding Specular Reflection Distance Max From Window WidthMeasuring Scanner Performance Quality Bar Code LabelsApplication Notes Tips for Achieving High Throughput Tips for Insuring Highest Data IntegrityTips for Verifying the Presence of a Bar Code Default Settings Section Configuring the ScannerProgramming Menus & Commands Parameter Factory Default SettingCommon Causes of Poor Performance Section Application Engineering SupportTechnical Assistance and Support Modified and/or Customized ScannersIEC 825-1 Class 1 Laser Device Section Scanner Servicing and MaintenanceSection Scanner Labeling Appendices ESC Computer Command CR Appendix aReset All Defaults U2 Command U2 What if you make a mistake?Options for UPC Global DefaultsSymbology Selection Options for EAN-8 & EAN-13Options for Code Prefix/Suffix of Numeric Characters Select Symbology forPrefix/Suffix Prefix/Suffix of Alpha CharactersParallel Read Mode Setting the Trigger & Auto-TriggerSelecting the Read Mode HandshakingMode Scanner Timeout Trigger EnabledXmit Error Trigger Enabled Mode only Quiet Zone OptionsAppendix C Computer Global Default & Scanner ConfigurationsCommand Description Including prefix/suffixSymbologies Symbology SelectionDescription Command Bar CodeOnly EAN 13/8 +2 Add/Activate Specific Bar Code Symbologies START/ENDDisable all symbologies Delete/Deactivate Specific Bar Code SymbologiesAdd/Activate Specific Bar Code Symbologies Bar Code Command Description Options for UPCOptions for EAN-8 & EAN-13 Options for Code 39 & IT Pharmaceutical IT Pharmaceutical, enable Transmit of leading a Options for Codabar NW-7 Codabar NW-7 Format Options for Interleaved & Industrial 2 5 Format Standard and InterleavedMeaning of Acronym Options for IataString format Number of digits 15 totalOptions for Code-128 / EAN-128 Options for Code-93Disable fixed length all Fixing the Number of DigitsCreating a Prefix and/or Suffix Setting Prefixes Identifying the Symbology UPC-E +2 or +5MSI/Plessey Setting Suffixes Identifying the Symbology Bar Code Command Description Direct Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case ETB Direct Input of Control CharactersSUB Direct Input Characters Misc Bar Code Command Description Code Identification & Characters/Digits Transmitted START/ENDCommunication Parameters Communication Parameters Handshaking TerminalMs intercharacter delay Disable buzzer Buzzer OperationSetting the Trigger & Auto-Trigger Functions Positive & Negative Bar CodesSelecting the Read Mode Trigger Function Enabled S8 Trigger Function Disabled S7Parallel labels only Parallel Read ModeAdd-on Wait Mode Applies to UPC/EAN only Scanner Timeout Trigger Enabled Mode only Multiple Read Reset Time Quiet Zone Options Redundant Decoding Transmitting Error Indications Trigger Enabled only Error Messages No decode / no labelGood Read LED Operation Appendix D Appendix E