Opticon LMD 1135 user manual Options for Code

Page 24

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Enable

Disable

Options for Code 39

8E

 

Enable 1 character read

8D

 

Enable 3 character read

C0

C1

Enable Check Digit calculation

D9

D8*

Transmit Check Digit

D0

D1

Transmit start/stop characters

 

 

(*…..*)

+L

+M

Concatenation

-Y

-Z

Alternative algorithm

*Only disable if C0 enabled, otherwise truncate last digit.

Enable

 

Disable

 

Options for IT Pharmaceutical

 

D6

 

 

 

IT Pharmaceutical only

 

DB

 

DA

 

Transmit Leading A

 

 

 

 

 

 

 

Enable

 

Disable

 

Options for Codabar (NW-7)

 

HC

 

 

 

Enable 1 character read minimum

 

HB

 

 

 

Enable 3 character read minimum

 

HF

 

 

 

Enable 5 character read minimum

 

F0

 

 

 

Do not transmit start/stop

 

 

 

 

 

characters

 

F1

 

 

 

Transmit start/stop as

 

 

 

 

 

ABCD/TN*E

 

F2

 

 

 

Transmit start/stop as abcd/tn*e

 

F3

 

 

 

Transmit start/stop as

 

 

 

 

 

ABCD/ABCD

 

F4

 

 

 

Transmit start/stop as abcd/abcd

 

H8

 

H9

 

Transmit check digit

 

H6

 

H7

 

Calculate check digit

 

HH

 

HI

 

Intercharacter gap check

 

-Y

 

-X

 

Alternative Algorithm

 

Enable

 

Disable

 

Options for 2 of 5 / SCode

G1

 

G0

 

Calculate check digit

E0

 

E1

 

Transmit check digit

GE

 

 

 

Enable 1 character minimum

GF

 

 

 

Enable 3 characters minimum

GI

 

 

 

Enable 5 characters minimum

GG

 

GH

 

Transmit S-Code as

 

 

 

 

Interleaved 2 of 5

-Y

 

-X

 

Alternative Algorithm

 

 

 

 

 

 

 

 

Enable

 

Disable

 

Options for IATA

4H

 

 

 

Do not calculate check digit

4J

 

 

 

Calculate CD (CPN + Form +

 

 

 

 

Serial)

4I

 

 

 

Calculate CD (Form + Serial)

4K

 

 

 

Calculate check digit (all data)

4L

 

4M

 

Transmit check digit

-Y

 

-X

 

Alternative Algorithm

 

 

 

 

 

 

 

 

Enable

 

Disable

 

 

Options Code 128/EAN 128

 

 

JF

 

OF

 

 

EAN-128 Only

 

 

MO

 

MP

 

 

Concatenation

 

 

 

 

 

 

 

 

 

Enable

 

Disable

 

 

Options for Code 93

 

+V

 

+W

 

 

Concatenation

 

 

 

 

 

 

Fixed Number of Digits

H1

 

Fixation on all symbologies

HK

 

Fixation on selected symbologies

HL

 

Minimum length selected symbologies

HM

 

Maximum length selected symbologies

H0

 

Disable fixation on all symbologies

Page 20

Image 24
Contents Manual No -ULPNR102-01 March OSE Command Set User’s ManualPage Contents Technical Specifications Configuring the ScannerScanner Servicing and Maintenance Introduction and Getting StartedQuick Start-Up Procedure Section Introduction and Getting StartedProduct Overview Page Section Technical Specifications Physical SpecificationsOptical Specifications Avoid specular reflection in the dead zone +/- 8 degrees Electrical Specifications JAN 13 R = 30 mm 1.2 orRS232 Communications Specifications Connector Pin-outsRS232 Signal Level RS232 Transmit / Receive Character FormatEnvironmental Specifications Pin No SignalOrdering Information ModelSection Positioning the Scanner for Optimum Performance Achieving Optimum PerformanceDistance to the Bar Code Depth-of-FieldAvoiding Specular Reflection Distance Max From Window WidthMeasuring Scanner Performance Quality Bar Code LabelsApplication Notes Tips for Achieving High Throughput Tips for Insuring Highest Data IntegrityTips for Verifying the Presence of a Bar Code Section Configuring the Scanner Programming Menus & CommandsDefault Settings Parameter Factory Default SettingSection Application Engineering Support Technical Assistance and SupportCommon Causes of Poor Performance Modified and/or Customized ScannersSection Scanner Servicing and Maintenance Section Scanner LabelingIEC 825-1 Class 1 Laser Device Appendices ESC Computer Command CR Appendix aReset All Defaults U2 Command U2 What if you make a mistake?Global Defaults Symbology SelectionOptions for UPC Options for EAN-8 & EAN-13Options for Code Select Symbology for Prefix/SuffixPrefix/Suffix of Numeric Characters Prefix/Suffix of Alpha CharactersSetting the Trigger & Auto-Trigger Selecting the Read ModeParallel Read Mode HandshakingScanner Timeout Trigger Enabled Xmit Error Trigger Enabled Mode onlyMode Quiet Zone OptionsAppendix C Global Default & Scanner Configurations Command DescriptionComputer Including prefix/suffixSymbology Selection Description CommandSymbologies Bar CodeOnly EAN 13/8 +2 Add/Activate Specific Bar Code Symbologies START/ENDDelete/Deactivate Specific Bar Code Symbologies Add/Activate Specific Bar Code SymbologiesDisable all symbologies Bar Code Command Description Options for UPCOptions for EAN-8 & EAN-13 Options for Code 39 & IT Pharmaceutical IT Pharmaceutical, enable Transmit of leading a Options for Codabar NW-7 Codabar NW-7 Format Options for Interleaved & Industrial 2 5 Format Standard and InterleavedOptions for Iata String formatMeaning of Acronym Number of digits 15 totalOptions for Code-128 / EAN-128 Options for Code-93Disable fixed length all Fixing the Number of DigitsCreating a Prefix and/or Suffix Setting Prefixes Identifying the Symbology UPC-E +2 or +5MSI/Plessey Setting Suffixes Identifying the Symbology Bar Code Command Description Direct Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case ETB Direct Input of Control CharactersSUB Direct Input Characters Misc Bar Code Command Description Code Identification & Characters/Digits Transmitted START/ENDCommunication Parameters Communication Parameters Handshaking TerminalMs intercharacter delay Disable buzzer Buzzer OperationSetting the Trigger & Auto-Trigger Functions Positive & Negative Bar CodesSelecting the Read Mode Trigger Function Enabled S8 Trigger Function Disabled S7Parallel Read Mode Add-on Wait Mode Applies to UPC/EAN onlyParallel labels only Scanner Timeout Trigger Enabled Mode only Multiple Read Reset Time Quiet Zone Options Redundant Decoding Transmitting Error Indications Trigger Enabled only Error Messages No decode / no labelGood Read LED Operation Appendix D Appendix E