Opticon LMD 1135 user manual Application Notes Tips for Achieving High Throughput

Page 15

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

Application Notes

Tips for Achieving High Throughput

In some applications your primary objective may be to achieve the highest possible throughput rate. The following list identifies the parameters and scanner settings that can maximize scanning and decode throughput speed. Note, by emphasizing maximum throughput, other areas of performance may be affected. For example, the number of non-reads could increase.

If high throughput is critical, consider some or all of these settings:

Operate in the Trigger Disabled mode. Operation of the trigger creates delay before decoding begins, slowing down throughput rate.

Only enable those symbologies that you will be decoding.

Eliminate all suffixes and prefixes to reduce transmission time.

Minimize the number of redundant reads required before transmitting data.

Transmit the decoded data at the highest baud rate.

Disable buzzer functions.

Tips for Insuring Highest Data Integrity

There are several parameters that can enhance your confidence that the correct bar code data is transmitted. Note that by emphasizing the accuracy and security of the data other areas of the scanner operation may be affected, for example, you may not achieve the highest throughput.

If accuracy and data integrity are critical, consider some or all of these settings:

Program the scanner to require a high number of redundant decodes prior to transmitting. For example, program the scanner to decode a bar code exactly the same way three consecutive times before transmitting the data. Then decoding the bar code the same way 2 out of 3 times or any 3 out of 4 times is not sufficient. It must obtain three consecutive, identical decodes.

Utilize a predetermined, fixed-length of bar code. Program the scanner to only decode a bar code of that length. Bar codes of any other length will be ignored.

The quality of the printed bar code must be excellent.

Use a bar code symbology that contains an internal check digit and program the scanner to calculate that check digit for validity prior to transmitting.

Do not use a symbology with poor internal verification, or subject to partial decodes, such as 2 of 5 or MSI/Plessey.

Only enable those symbologies that you will be decoding.

Transmit data at low baud rates to minimize communication errors.

Enable the “Number of Characters Transmitted”. The scanner will calculate and transmit a number indicating the total number of characters it is transmitting. Your host application program can compare this number with the actual number of characters received to verify that the correct amount of data is received.

Page 11

Image 15
Contents User’s Manual Manual No -ULPNR102-01 March OSE Command SetPage Contents Introduction and Getting Started Technical SpecificationsConfiguring the Scanner Scanner Servicing and MaintenanceQuick Start-Up Procedure Section Introduction and Getting StartedProduct Overview Page Section Technical Specifications Physical SpecificationsOptical Specifications Avoid specular reflection in the dead zone +/- 8 degrees JAN 13 R = 30 mm 1.2 or Electrical SpecificationsRS232 Transmit / Receive Character Format RS232 Communications SpecificationsConnector Pin-outs RS232 Signal LevelModel Environmental SpecificationsPin No Signal Ordering InformationDepth-of-Field Section Positioning the Scanner for Optimum PerformanceAchieving Optimum Performance Distance to the Bar CodeDistance Max From Window Width Avoiding Specular ReflectionQuality Bar Code Labels Measuring Scanner PerformanceTips for Insuring Highest Data Integrity Application Notes Tips for Achieving High ThroughputTips for Verifying the Presence of a Bar Code Parameter Factory Default Setting Section Configuring the ScannerProgramming Menus & Commands Default SettingsModified and/or Customized Scanners Section Application Engineering SupportTechnical Assistance and Support Common Causes of Poor PerformanceSection Scanner Servicing and Maintenance Section Scanner LabelingIEC 825-1 Class 1 Laser Device Appendices Appendix a ESC Computer Command CRWhat if you make a mistake? Reset All Defaults U2 Command U2Options for EAN-8 & EAN-13 Global DefaultsSymbology Selection Options for UPCOptions for Code Prefix/Suffix of Alpha Characters Select Symbology forPrefix/Suffix Prefix/Suffix of Numeric CharactersHandshaking Setting the Trigger & Auto-TriggerSelecting the Read Mode Parallel Read ModeQuiet Zone Options Scanner Timeout Trigger EnabledXmit Error Trigger Enabled Mode only ModeAppendix C Including prefix/suffix Global Default & Scanner ConfigurationsCommand Description ComputerBar Code Symbology SelectionDescription Command SymbologiesOnly EAN 13/8 +2 START/END Add/Activate Specific Bar Code SymbologiesDelete/Deactivate Specific Bar Code Symbologies Add/Activate Specific Bar Code SymbologiesDisable all symbologies Options for UPC Bar Code Command DescriptionOptions for EAN-8 & EAN-13 Options for Code 39 & IT Pharmaceutical IT Pharmaceutical, enable Transmit of leading a Options for Codabar NW-7 Codabar NW-7 Format 5 Format Standard and Interleaved Options for Interleaved & Industrial 2Number of digits 15 total Options for IataString format Meaning of AcronymOptions for Code-93 Options for Code-128 / EAN-128Fixing the Number of Digits Disable fixed length allCreating a Prefix and/or Suffix UPC-E +2 or +5 Setting Prefixes Identifying the SymbologyMSI/Plessey Setting Suffixes Identifying the Symbology Bar Code Command Description Direct Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case Direct Input of Control Characters ETBSUB Direct Input Characters Misc Bar Code Command Description START/END Code Identification & Characters/Digits TransmittedCommunication Parameters Communication Parameters Terminal HandshakingMs intercharacter delay Buzzer Operation Disable buzzerPositive & Negative Bar Codes Setting the Trigger & Auto-Trigger FunctionsTrigger Function Enabled S8 Trigger Function Disabled S7 Selecting the Read ModeParallel Read Mode Add-on Wait Mode Applies to UPC/EAN onlyParallel labels only Scanner Timeout Trigger Enabled Mode only Multiple Read Reset Time Quiet Zone Options Redundant Decoding Error Messages No decode / no label Transmitting Error Indications Trigger Enabled onlyGood Read LED Operation Appendix D Appendix E