Opticon LMD 1135 user manual Handshaking, Terminal

Page 59

Manual No. 25-ULPNR102-01; Mar, 2005

LMD 1135 Laser Fixed Mount Scanner

24. Handshaking

Computer

Function

Bar Code

 

Command

/Description

Command

 

(ZZ)

START/END

[[

￿

Programming Menu

 

 

 

 

I0

Unlimited wait for CTS from

J1

￿

terminal

 

 

 

 

I1

100 mS wait for CTS from

J2

￿

terminal

 

 

 

 

I2

200 mS wait for CTS from

J3

￿

terminal

 

 

 

 

I3

400 mS for CTS from terminal

J!

￿

 

 

 

 

 

P0

No Handshaking

Q1

￿

 

 

 

 

 

P1

Busy/Ready

Q2

￿

 

 

 

 

 

P2

Modem

Q3

￿

 

 

 

 

 

P3

ACK/NAK (1 sec timeout with

Q!

￿

error buzzer)

 

 

 

 

P4

ACK/NAK no response (100 ms

Q5

￿

timeout, terminates with good

 

read buzzer)

 

 

 

 

 

 

ZG

XON/XOFF

[H

￿

 

 

 

 

KA

No intercharacter delay

LB

￿

 

 

 

 

KB

20 ms intercharacter delay

LC

￿

 

 

 

 

￿

%￿

￿

￿

￿

%￿

￿

￿

￿

￿

￿

%￿

￿

CONTINUED ON NEXT PAGE…

Page 55

Image 59
Contents User’s Manual Manual No -ULPNR102-01 March OSE Command SetPage Contents Introduction and Getting Started Technical SpecificationsConfiguring the Scanner Scanner Servicing and MaintenanceProduct Overview Quick Start-Up ProcedureSection Introduction and Getting Started Page Optical Specifications Section Technical SpecificationsPhysical Specifications Avoid specular reflection in the dead zone +/- 8 degrees JAN 13 R = 30 mm 1.2 or Electrical SpecificationsRS232 Transmit / Receive Character Format RS232 Communications SpecificationsConnector Pin-outs RS232 Signal LevelModel Environmental SpecificationsPin No Signal Ordering InformationDepth-of-Field Section Positioning the Scanner for Optimum PerformanceAchieving Optimum Performance Distance to the Bar CodeDistance Max From Window Width Avoiding Specular ReflectionQuality Bar Code Labels Measuring Scanner PerformanceTips for Insuring Highest Data Integrity Application Notes Tips for Achieving High ThroughputTips for Verifying the Presence of a Bar Code Parameter Factory Default Setting Section Configuring the ScannerProgramming Menus & Commands Default SettingsModified and/or Customized Scanners Section Application Engineering SupportTechnical Assistance and Support Common Causes of Poor PerformanceIEC 825-1 Class 1 Laser Device Section Scanner Servicing and MaintenanceSection Scanner Labeling Appendices Appendix a ESC Computer Command CRWhat if you make a mistake? Reset All Defaults U2 Command U2Options for EAN-8 & EAN-13 Global DefaultsSymbology Selection Options for UPCOptions for Code Prefix/Suffix of Alpha Characters Select Symbology forPrefix/Suffix Prefix/Suffix of Numeric CharactersHandshaking Setting the Trigger & Auto-TriggerSelecting the Read Mode Parallel Read ModeQuiet Zone Options Scanner Timeout Trigger EnabledXmit Error Trigger Enabled Mode only ModeAppendix C Including prefix/suffix Global Default & Scanner ConfigurationsCommand Description ComputerBar Code Symbology SelectionDescription Command SymbologiesOnly EAN 13/8 +2 START/END Add/Activate Specific Bar Code SymbologiesDisable all symbologies Delete/Deactivate Specific Bar Code SymbologiesAdd/Activate Specific Bar Code Symbologies Options for UPC Bar Code Command DescriptionOptions for EAN-8 & EAN-13 Options for Code 39 & IT Pharmaceutical IT Pharmaceutical, enable Transmit of leading a Options for Codabar NW-7 Codabar NW-7 Format 5 Format Standard and Interleaved Options for Interleaved & Industrial 2Number of digits 15 total Options for IataString format Meaning of AcronymOptions for Code-93 Options for Code-128 / EAN-128Fixing the Number of Digits Disable fixed length allCreating a Prefix and/or Suffix UPC-E +2 or +5 Setting Prefixes Identifying the SymbologyMSI/Plessey Setting Suffixes Identifying the Symbology Bar Code Command Description Direct Input of Numeric Characters Direct Input of Alpha Characters Direct Input of Alpha Characters Lower Case Direct Input of Control Characters ETBSUB Direct Input Characters Misc Bar Code Command Description START/END Code Identification & Characters/Digits TransmittedCommunication Parameters Communication Parameters Terminal HandshakingMs intercharacter delay Buzzer Operation Disable buzzerPositive & Negative Bar Codes Setting the Trigger & Auto-Trigger FunctionsTrigger Function Enabled S8 Trigger Function Disabled S7 Selecting the Read ModeParallel labels only Parallel Read ModeAdd-on Wait Mode Applies to UPC/EAN only Scanner Timeout Trigger Enabled Mode only Multiple Read Reset Time Quiet Zone Options Redundant Decoding Error Messages No decode / no label Transmitting Error Indications Trigger Enabled onlyGood Read LED Operation Appendix D Appendix E