SSI America EPS2U manual Grounding, Remote Sense, Server Signal Connector

Page 16

SSI

EPS2U Power Supply Design Guide, V2.1

If the optional server signal connector is not used on the power supply or the connector is unplugged, the power supply shall utilize the 3.3RS on the baseboard connector (Pin 1).

Connector housing: 5-pin Molex 50-57-9405 or equivalent

Contacts: Molex 16-02-0088 or equivalent (gold plated)

Table 13: Server Signal Connector

Pin

Signal

24 AWG Color

1

I2C Clock

White/Green Stripe

 

 

 

2

I2C Data

White/Yellow Stripe

 

 

 

3

Reserved

NA

 

 

 

4

ReturnS

Black/White Stripe

 

 

 

5

3.3RS

Orange/White Stripe

 

 

 

6.2Grounding

STATUS

Required

The ground of the pins of the power supply wire harness provides the power return path. The wire harness ground pins shall be connected to safety ground (power supply enclosure).

6.3Remote Sense

STATUS

Optional

The power supply may have remote sense for the +3.3V (3.3VS) and return (ReturnS) if the Optional Server Signal connector is implemented. The remote sense return (ReturnS) is used to regulate out ground drops for all output voltages; +3.3V, +5 V, +12V1, +12V2, +12V3, -12 V, and 5 VSB. The 3.3V remote sense (3.3VS) is used to regulate out drops in the system for the +3.3 V output. The remote sense input impedance to the power supply must be greater than 200 W on 3.3 VS and ReturnS. This is the value of the resistor connecting the remote sense to the output voltage internal to the power supply. Remote sense must be able to regulate out a minimum of 200 mV drop on the +3.3 V output. The remote sense return (ReturnS) must be able to regulate out a minimum of 200 mV drop in the power ground return. The current in any remote sense line shall be less than 5 mA to prevent voltage sensing errors. The power supply must operate within specification over the full range of voltage drops from the power supply’s output connector to the remote sense points.

- 16 -

Image 16
Contents SSI Disclaimer Contents Figures TablesPurpose Conceptual OverviewDefinitions/Terms/Acronyms RequiredMechanical Overview Required OptionalTemperature Requirements Airflow RequirementsRecommended Thermal RequirementsAC Inlet Connector AC Input Voltage SpecificationAC Input Requirements EfficiencyAC Line Transient Specification AC Line DropoutAC Line Fuse AC InrushAC Line Fast Transient Specification AC Line Sag Transient PerformanceAC Line Surge Transient Performance AC Line SurgeDC Output Specification Output Connectors1 12V Power Rail Configurations 12V Rail Summary Baseboard power connector P1 Baseboard Power Connector Common Plane Pin Signal AWG Color P1 Baseboard Power Connector Split PlaneProcessor Power Connector Common Plane Processor Power ConnectorProcessor Power Connector Split Plane Peripheral Power Connectors Floppy Power ConnectorServer Signal Connector Peripheral Power ConnectorsGrounding Server Signal ConnectorRemote Sense Output Power/Currents 480 W Load Ratings Common PlaneVoltage Minimum Continuous Maximum Continuous Peak 550 W Load Ratings Split Plane600 W Load Ratings Split Plane Standby Outputs650 W Load Ratings Split Plane Voltage Regulation Voltage Regulation LimitsParameter Units ToleranceDynamic Loading Capacitive LoadingTransient Load Requirements Capacitve Loading ConditionsRipple / Noise Timing RequirementsRipple and Noise Output Voltage TimingOutput Voltage Timing Turn On/Off Timing Turn On/Off Timing Single Power Supply Recommended DescriptionProtection Circuits Current Limit240VA Protection Over Current ProtectionOver Temperature Protection Over Voltage ProtectionOver Voltage Limits Output VoltageControl and Indicator Functions Pson # Signal Characteristic Signal TypePwok delay PSON#Pwok Power OK Field Replacement Unit FRU SignalsPwok Signal Characteristics FRU DataFRU Data Format Product Info AreaFRU Device Information FRU Device Product Information AreaMultiRecord Area Field Name PS Info Field Information DefinitionMtbf Agency Requirements