SSI America EPS2U manual AC Line Fast Transient Specification, AC Line Sag Transient Performance

Page 11

 

 

 

 

 

 

SSI

 

 

 

 

 

 

EPS2U Power Supply Design Guide, V2.1

 

 

 

 

Table 4: AC Line Sag Transient Performance

 

 

 

 

AC Line Sag

 

 

 

 

 

Duration

Sag

Operating AC Voltage

Line Frequency

Performance Criteria

 

 

 

 

 

 

 

 

 

 

 

Continuous

10%

Nominal AC Voltage ranges

50/60 Hz

No loss of function or performance

 

 

 

 

 

 

 

 

 

 

 

0 to 1 AC

100%

Nominal AC Voltage ranges

50/60 Hz

No loss of function or performance

 

 

cycle

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

>1 AC cycle

>10%

Nominal AC Voltage ranges

50/60 Hz

Loss of function acceptable, self

 

 

 

 

 

 

recoverable

 

 

 

 

Table 5: AC Line Surge Transient Performance

 

 

 

 

 

AC Line Surge

 

 

 

 

 

Duration

Surge

Operating AC Voltage

Line Frequency

Performance Criteria

 

 

 

 

 

 

 

 

 

 

Continuous

10%

Nominal AC Voltages

50/60 Hz

No loss of function or performance

 

 

 

 

 

 

 

 

 

 

0 to ½ AC

30%

Mid-point of nominal AC

50/60 Hz

No loss of function or performance

 

 

cycle

 

Voltages

 

 

 

 

5.8AC Line Fast Transient Specification

STATUS

Recommended

The power supply shall meet the EN61000-4-5directive and any additional requirements in IEC1000-4-5:1995and the Level 3 requirements for surge-withstand capability, with the following conditions and exceptions:

These input transients must not cause any out-of-regulation conditions, such as overshoot and undershoot, nor must it cause any nuisance trips of any of the power supply protection circuits.

The surge-withstand test must not produce damage to the power supply.

The supply must meet surge-withstand test conditions under maximum and minimum DC-output load conditions.

- 11 -

Image 11
Contents SSI Disclaimer Contents Tables FiguresConceptual Overview PurposeRequired Definitions/Terms/AcronymsRequired Optional Mechanical Overview Thermal Requirements Temperature Requirements Airflow Requirements RecommendedEfficiency AC Inlet ConnectorAC Input Voltage Specification AC Input RequirementsAC Inrush AC Line Transient SpecificationAC Line Dropout AC Line FuseAC Line Surge AC Line Fast Transient SpecificationAC Line Sag Transient Performance AC Line Surge Transient Performance12V Rail Summary DC Output SpecificationOutput Connectors 1 12V Power Rail ConfigurationsP1 Baseboard Power Connector Split Plane Baseboard power connectorP1 Baseboard Power Connector Common Plane Pin Signal AWG ColorProcessor Power Connector Split Plane Processor Power ConnectorProcessor Power Connector Common Plane Peripheral Power Connectors Peripheral Power ConnectorsFloppy Power Connector Server Signal ConnectorRemote Sense Server Signal ConnectorGrounding 550 W Load Ratings Split Plane Output Power/Currents480 W Load Ratings Common Plane Voltage Minimum Continuous Maximum Continuous Peak650 W Load Ratings Split Plane Standby Outputs600 W Load Ratings Split Plane Units Tolerance Voltage RegulationVoltage Regulation Limits ParameterCapacitve Loading Conditions Dynamic LoadingCapacitive Loading Transient Load RequirementsOutput Voltage Timing Ripple / NoiseTiming Requirements Ripple and NoiseOutput Voltage Timing Turn On/Off Timing Recommended Description Turn On/Off Timing Single Power SupplyOver Current Protection Protection CircuitsCurrent Limit 240VA ProtectionOutput Voltage Over Temperature ProtectionOver Voltage Protection Over Voltage LimitsPSON# Control and Indicator FunctionsPson # Signal Characteristic Signal Type Pwok delayFRU Data Pwok Power OKField Replacement Unit FRU Signals Pwok Signal CharacteristicsFRU Device Product Information Area FRU Data FormatProduct Info Area FRU Device InformationField Name PS Info Field Information Definition MultiRecord AreaAgency Requirements Mtbf