SSI
EPS2U Power Supply Design Guide, V2.1
6.1.4Peripheral Power Connectors
STATUS
Required
Connector housing: Amp
Contact: Amp
Table 11: Peripheral Power Connectors
Pin | Signal | 18 AWG Color |
1 | +12V2 (+12V3 or +12V4) 1, 2 | Yellow (Yellow/Blue Stripe or Yellow/Green stripe) 1, 2 |
2 | COM | Black |
|
|
|
3 | COM | Black |
|
|
|
4 | +5 VDC | Red |
|
|
|
1.The +12V power to peripherals may be split between the second, third, or fourth +12V channel for the purpose of limiting power to less than 240VA.
2.If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color.
6.1.5Floppy Power Connector
STATUS
Required
Connector housing: Amp
Table 12: P9 Floppy Power Connector
Pin | Signal | 22 AWG Color |
1 | +5 VDC | Red |
|
|
|
2 | COM | Black |
|
|
|
3 | COM | Black |
|
|
|
4 | +12V2 (+12V3 or +12V4) 1, 2 | Yellow (Yellow/Blue Stripe or Yellow/Green stripe) 1, 2 |
1.The +12V power to peripherals may be split between the second, third, or fourth +12V channel for the purpose of limiting power to less than 240VA.
2.If 240VA limiting is not a requirement for the power supply than all +12V outputs are common and may have the same wire color.
6.1.6Server Signal Connector
STATUS
Optional
For server systems with SMBus features, the power supply may have an additional connector, which provides serial SMBus for FRU data and remote sense on 3.3V and Return.
- 15 -