SSI America EPS2U manual Over Voltage Protection, Over Temperature Protection, Over Voltage Limits

Page 25

 

 

 

SSI

 

 

 

EPS2U Power Supply Design Guide, V2.1

 

 

Table 26: Over Current Protection

 

 

 

Common Plane

Split Plane

 

 

Voltage

Over Current Limit (Iout limit)

Over Current Limit (Iout limit)

 

 

+3.3 V

110% minimum; 150% maximum

110% minimum; 150% maximum

 

 

 

 

 

 

+5 V

110% minimum; 150% maximum

110% minimum; 150% maximum

 

 

 

 

 

 

+12V1

18A minimum; 20A maximum; 22A peak1

15A minimum; 20A maximum

 

 

+12V2

Peak current minimum; 20A maximum

Peak current minimum; 20A maximum

 

 

 

 

 

 

+12V3

Peak current minimum; 20A maximum (550W only)

Peak current minimum; 20A maximum

 

 

 

 

 

 

+12V4

N/A

Peak current minimum; 20A maximum

 

 

 

 

 

1.+12V1 peak currents shall be maintained for a minimum of 500msec. The maximum duration of the peak current exceeding the 240VA limit should be limited to meet safety regulations. A maximum duration of 1 second is recommended.

7.3Over Voltage Protection

STATUS

Required

The power supply over voltage protection shall be locally sensed. The power supply shall shutdown and latch off after an over voltage condition occurs. This latch shall be cleared by toggling the PSON# signal or by an AC power interruption. Table 27 contains the over voltage limits. The values are measured at the output of the power supply’s connectors. The voltage shall never exceed the maximum levels when measured at the power pins of the power supply connector during any single point of fail. The voltage shall never trip any lower than the minimum levels when measured at the power pins of the power supply connector.

Table 27: Over Voltage Limits

Output Voltage

MIN (V)

MAX (V)

+3.3 V

3.9

4.5

 

 

 

+5 V

5.7

6.5

 

 

 

+12V1,2,3

13.3

14.5

 

 

 

-12 V

-13.3

-14.5

 

 

 

+5 VSB

5.7

6.5

 

 

 

7.4Over Temperature Protection

STATUS

Recommended

The power supply will be protected against over temperature conditions caused by loss of fan cooling or excessive ambient temperature. In an OTP condition the PSU will shutdown. When the power supply temperature drops to within specified limits, the power supply shall restore power automatically. The OTP circuit must have built in hysteresis such that the power supply will not oscillate on and off due to temperature recovering condition. The OTP trip level shall have a minimum of 4 °C of ambient temperature hysteresis.

- 25 -

Image 25
Contents SSI Disclaimer Contents Tables FiguresConceptual Overview PurposeRequired Definitions/Terms/AcronymsRequired Optional Mechanical OverviewAirflow Requirements Temperature RequirementsRecommended Thermal RequirementsAC Input Voltage Specification AC Inlet ConnectorAC Input Requirements EfficiencyAC Line Dropout AC Line Transient SpecificationAC Line Fuse AC InrushAC Line Sag Transient Performance AC Line Fast Transient SpecificationAC Line Surge Transient Performance AC Line SurgeOutput Connectors DC Output Specification1 12V Power Rail Configurations 12V Rail SummaryP1 Baseboard Power Connector Common Plane Baseboard power connectorPin Signal AWG Color P1 Baseboard Power Connector Split PlaneProcessor Power Connector Common Plane Processor Power ConnectorProcessor Power Connector Split Plane Floppy Power Connector Peripheral Power ConnectorsServer Signal Connector Peripheral Power ConnectorsGrounding Server Signal ConnectorRemote Sense 480 W Load Ratings Common Plane Output Power/CurrentsVoltage Minimum Continuous Maximum Continuous Peak 550 W Load Ratings Split Plane600 W Load Ratings Split Plane Standby Outputs650 W Load Ratings Split Plane Voltage Regulation Limits Voltage RegulationParameter Units ToleranceCapacitive Loading Dynamic LoadingTransient Load Requirements Capacitve Loading ConditionsTiming Requirements Ripple / NoiseRipple and Noise Output Voltage TimingOutput Voltage Timing Turn On/Off Timing Recommended Description Turn On/Off Timing Single Power SupplyCurrent Limit Protection Circuits240VA Protection Over Current ProtectionOver Voltage Protection Over Temperature ProtectionOver Voltage Limits Output VoltagePson # Signal Characteristic Signal Type Control and Indicator FunctionsPwok delay PSON#Field Replacement Unit FRU Signals Pwok Power OKPwok Signal Characteristics FRU DataProduct Info Area FRU Data FormatFRU Device Information FRU Device Product Information AreaField Name PS Info Field Information Definition MultiRecord AreaAgency Requirements Mtbf