SSI America EPS2U manual MultiRecord Area, Field Name PS Info Field Information Definition

Page 29

SSI

EPS2U Power Supply Design Guide, V2.1

8.3.2.2MultiRecord Area

Implement as defined by the IPMI FRU document. The following record types shall be used on this power supply:

Power Supply Information (Record Type 0x00)

DC Output (Record Type 0x01)

No other record types are required for the power supply.

MultiRecord information shall be defined as follows:

Table 32: FRU Device Product Information Area

Field Name (PS Info)

Field Information Definition

Overall Capacity (watts)

480

 

 

Peak VA

550

 

 

Inrush current (A)

50

 

 

Inrush interval (ms)

5

 

 

Low end input voltage range 1

90

 

 

High end input voltage range 1

140

 

 

Low end input voltage range 2

180

 

 

High end input voltage range 2

264

 

 

A/C dropout tol. (ms)

20

 

 

Binary flags

Set for: Hot Swap support, Autoswitch, and PFC

 

 

Peak Wattage

Set for: 10 s, 550 W

 

 

Combined wattage

Set for 5 V & 3.3V combined wattage of 115 W

 

 

Predictive fail tach support

Not supported, 00h value

 

 

Field Name (Output)

Field Description:

 

Five outputs are to be defined from #1 to #5, as follows: +3.3 V, +5

 

V, +12 V, -12V, and +5 VSB.

 

 

Output Information

Set for: Standby on +5 VSB, No Standby on all others.

 

 

All other output fields

Format per IPMI specification, using parameters in the EPS12V

 

specification.

 

 

- 29 -

Image 29
Contents SSI Disclaimer Contents Tables FiguresConceptual Overview PurposeRequired Definitions/Terms/AcronymsRequired Optional Mechanical OverviewAirflow Requirements Temperature RequirementsRecommended Thermal RequirementsAC Input Voltage Specification AC Inlet ConnectorAC Input Requirements EfficiencyAC Line Dropout AC Line Transient SpecificationAC Line Fuse AC InrushAC Line Sag Transient Performance AC Line Fast Transient SpecificationAC Line Surge Transient Performance AC Line SurgeOutput Connectors DC Output Specification1 12V Power Rail Configurations 12V Rail SummaryP1 Baseboard Power Connector Common Plane Baseboard power connectorPin Signal AWG Color P1 Baseboard Power Connector Split PlaneProcessor Power Connector Split Plane Processor Power ConnectorProcessor Power Connector Common Plane Floppy Power Connector Peripheral Power ConnectorsServer Signal Connector Peripheral Power ConnectorsRemote Sense Server Signal ConnectorGrounding 480 W Load Ratings Common Plane Output Power/CurrentsVoltage Minimum Continuous Maximum Continuous Peak 550 W Load Ratings Split Plane650 W Load Ratings Split Plane Standby Outputs600 W Load Ratings Split Plane Voltage Regulation Limits Voltage RegulationParameter Units ToleranceCapacitive Loading Dynamic LoadingTransient Load Requirements Capacitve Loading ConditionsTiming Requirements Ripple / NoiseRipple and Noise Output Voltage TimingOutput Voltage Timing Turn On/Off Timing Recommended Description Turn On/Off Timing Single Power SupplyCurrent Limit Protection Circuits240VA Protection Over Current ProtectionOver Voltage Protection Over Temperature ProtectionOver Voltage Limits Output VoltagePson # Signal Characteristic Signal Type Control and Indicator FunctionsPwok delay PSON#Field Replacement Unit FRU Signals Pwok Power OKPwok Signal Characteristics FRU DataProduct Info Area FRU Data FormatFRU Device Information FRU Device Product Information AreaField Name PS Info Field Information Definition MultiRecord AreaAgency Requirements Mtbf