SSI

EPS2U Power Supply Design Guide, V2.1

Contents

1

2

3

4

Purpose

5

Conceptual Overview

5

Definitions/Terms/Acronyms

6

Mechanical Overview

7

4.1

Airflow Requirements

8

4.2

Temperature Requirements

8

5

AC Input Requirements

9

5.1

AC Inlet Connector

9

5.2

AC Input Voltage Specification

9

5.3

Efficiency

9

5.4

AC Line Dropout

10

5.5

AC Line Fuse

10

5.6

AC Inrush

10

5.7

AC Line Transient Specification

10

5.8

AC Line Fast Transient Specification

11

6

DC Output Specification

12

6.1

Output Connectors

12

6.1.1

12V Power Rail Configurations

12

6.1.2

Baseboard power connector

13

6.1.3

Processor Power Connector

14

6.1.4

Peripheral Power Connectors

15

6.1.5

Floppy Power Connector

15

6.1.6

Server Signal Connector

15

6.2

Grounding

16

6.3

Remote Sense

16

6.4

Output Power/Currents

17

6.4.1

Standby Outputs

18

6.5

Voltage Regulation

19

6.6

Dynamic Loading

20

6.7

Capacitive Loading

20

6.8

Ripple / Noise

21

6.9

Timing Requirements

21

7

Protection Circuits

24

7.1

Current Limit

24

7.2

240VA Protection

24

7.3

Over Voltage Protection

25

7.4

Over Temperature Protection

25

8

Control and Indicator Functions

26

8.1

PSON#

26

8.2

PWOK (Power OK)

27

8.3

Field Replacement Unit (FRU) Signals

27

8.3.1

FRU Data

27

8.3.2

FRU Data Format

28

 

 

- 3 -

Image 3
Contents SSI Disclaimer Contents Tables FiguresConceptual Overview PurposeRequired Definitions/Terms/AcronymsRequired Optional Mechanical OverviewThermal Requirements Temperature RequirementsAirflow Requirements RecommendedEfficiency AC Inlet ConnectorAC Input Voltage Specification AC Input RequirementsAC Inrush AC Line Transient SpecificationAC Line Dropout AC Line FuseAC Line Surge AC Line Fast Transient SpecificationAC Line Sag Transient Performance AC Line Surge Transient Performance12V Rail Summary DC Output SpecificationOutput Connectors 1 12V Power Rail ConfigurationsP1 Baseboard Power Connector Split Plane Baseboard power connectorP1 Baseboard Power Connector Common Plane Pin Signal AWG ColorProcessor Power Connector Processor Power Connector Common PlaneProcessor Power Connector Split Plane Peripheral Power Connectors Peripheral Power ConnectorsFloppy Power Connector Server Signal ConnectorServer Signal Connector GroundingRemote Sense 550 W Load Ratings Split Plane Output Power/Currents480 W Load Ratings Common Plane Voltage Minimum Continuous Maximum Continuous PeakStandby Outputs 600 W Load Ratings Split Plane650 W Load Ratings Split Plane Units Tolerance Voltage RegulationVoltage Regulation Limits ParameterCapacitve Loading Conditions Dynamic LoadingCapacitive Loading Transient Load RequirementsOutput Voltage Timing Ripple / NoiseTiming Requirements Ripple and NoiseOutput Voltage Timing Turn On/Off Timing Recommended Description Turn On/Off Timing Single Power SupplyOver Current Protection Protection CircuitsCurrent Limit 240VA ProtectionOutput Voltage Over Temperature ProtectionOver Voltage Protection Over Voltage LimitsPSON# Control and Indicator FunctionsPson # Signal Characteristic Signal Type Pwok delayFRU Data Pwok Power OKField Replacement Unit FRU Signals Pwok Signal CharacteristicsFRU Device Product Information Area FRU Data FormatProduct Info Area FRU Device InformationField Name PS Info Field Information Definition MultiRecord AreaAgency Requirements Mtbf