Software Version Changes

The changes for power supply software version 3.0 from previous software versions are summarized below.

1.Added menus tree items to display data specific to CXI color changer.

2.The fan control DMX channel can be selected to be one channel or be a block of channels for individual color changer fan speed control (this block of channels is 24 for a 24 way power supply, 12 for a 12 way power supply and 6 for a 6 way power supply)

3.Removed the clock function

4.The display will show the actual channel range used (e.g. 1-6 if 6 Coloram color changers are used and talkback is OFF). If talkback is ON the upper channel shown will be the last channel used by the power supply for talkback.

5.In the CRI mode, the power supply can control more color changers on separate channels.

6.Increased the highest starting channel (see the chart below)

Power supply

 

TlkBk

TlkBk

desc.

model #

ON

OFF

24 way

19000

511

512

 

12 way

19012

511

512

 

6 way

19060

511

512

 

Parts list

To order any of the following items, contact your authorized WYBRON dealer.

The Coloram II Power Supplies

19000

Coloram II 24 Way Power Supply

19012

Coloram II 12 Way Power Supply

19060

Coloram II 6 Way Power Supply

The Coloram II mounting and installation accessories

1900-01-05P ..... 24 Way Power Supply hanger bracket

715-01-03P

6 Way and 12 Way Power Supply hanger bracket

SCRWC252075

Wing screw for Power Supply hanger bracket to pipe

SCRSC2520037 Socket cap screw for hanger bracket to Power Supply

23

Image 23
Contents Page Contents Introduction Coloram II System Color Changers and Other Components Coloram II System ComponentsColoram Cables Power SupplyColoram II Power Supply menu RUN Screen Loop Power UP ScreensAlerts / Error Messages Menu DetailsPage XX Units For The CXI color changer Setup Options 001001 + + Commands001 + Connect the Color Changers to the Power Supply Mount the Power SupplySet the Power Supply/Color Changer channels Connect the Power Supply to AC powerConnect and set the DMX512 source Head-Feet RestrictionsHead-Feet Example Mounting and installation accessoriesPower Supply hanger brackets Power Supply rack mounting Coloram cable Equipment CompatibilityCables DMX512 control cable SpecificationsColoram II Power Supply Software Version Changes Parts listColoram II Power Supplies Coloram II mounting and installation accessoriesColoram II System cable Warranty informationWYBRON, INC. TEL 719-548-9774- FAX