Panasonic WJ-GXE900, WJ-GXD900 manual ALARM-DRY Contact

Page 48

SETTINGS MENUS OF THE ENCODER

ALARM-DRY CONTACT page

Note: Click the [SET] button to save the changed settings. Otherwise, the changed settings will not be saved.

Item Descriptions

No.

The numbers of the ALARM IN connectors

MAKE CONTACT

Set whether to control the encoder by making contact or not.

When an alarm input continues for more than 100 ms, the encoder regards it as an alarm occurrence.

OPEN

When a closed contact is opened, the encoder regards it as an alarm occurrence.

CLOSE

When an open contact is closed, the encoder regards it as an alarm occurrence.

OFF

The encoder does not detect any alarm from the correspondent port. No alarm notification is sent.

When "OPEN" or "CLOSE" is selected, the following actions will be performed at the same time.

Notification of an alarm occurrence to the destination set on the ALARM page using the TCP/IP command

Camera is controlled by a preset number

Changing of the bit rate

The default setting is "CLOSE" for all ports.

VIDEO INPUT CH

The numbers of the VIDEO IN connectors

CAMERA PRESET No. (1 - 16)

When the encoder detects an alarm from a camera with preset functions connected to the VIDEO IN connector, the encoder performs the preset control on the camera. In this case, the preset function settings for the camera to be controlled should be performed in advance.

This setting is invalid when a camera without the preset functions is connected.

There is no default setting.

BIT RATE

When the encoder detects an alarm, the encoder changes the bit rate of the streaming video data temporarily. The bit rate of up to 4 streams can be changed simultaneously when an alarm is detected. The default setting is "6.14 Mbps (150 ms)" for all channels.

48

Image 48
Contents Operating Instructions English Version Important Safety Instructions Contents Resetting the Alarm / Displaying the Alarm Status Controlling the BIT Rate of Streaming VideoFeatures Precautions TCP/IP, UDP, HTTP, FTP, ARP, Bootp System RequirementsLimitation of Liability CPUTrademarks and Registered Trademarks Document ConventionPower Indicator Operate Status Indicators Status 1Rotary Switch SW1 A, B, C Dip Switches 1 8 SW2Reset Button Reset BNC Network Status Indicators LINK1, 100, 1000, ACT MPEG2 Decoder Front PanelRS-232C 9-pin D-sub Signal Ground Terminal Signal GND Power Cord Ethernet Port 100BASE-TX/1000BASE-T RJ-45Connections Multicast TransmissionVideo System Example Switching streaming video 100BASE-TXOperation Example Switching streaming video Controlling cameraAddress=aaa.aaa.aaa.aaappppp System example Recording streaming video Digital Disk Recorder WJ-HD500 SeriesSetting Example Recording streaming video RS-485 Data Port SetupNetwork Port Setup Operation Example Recording streaming videoUnicast Transmission System ExampleRequired Settings for RS-485 Receiving and Sending Serial Data RS-485Alarm Function and a Reset Switch Alarm ResetAlarms Action of the encoder when an alarm is receivedAlarm notification command Details of the TCP/IP Data partAlarm Reset Audio IN/AUDIO OUTInstallations Places to avoidAbout mounting Heat DissipationRack Mounting Mounting the decoderMounting the encoder Installing in a container box Only for the Encoder How to installLabels for Encoder Labels for DecoderDescription label Code labelSetup Before Starting SettingsSetup with the Provided Panasonic IP Setup Software Items included in the softwareSetup Network Setup of the PC Using Windows 98 SESetup Using Windows Setup Using Windows XP Category View Setup Settings Menus of the Encoder Top page of the encoderAlarm MaintenanceCONTROL/STATE NetworkCONTROL/STATE Item DescriptionsEncode State ControlWhen using multicast transmission When using unicast transmissionVideo Camera NoEncoder Start UP Setup BIT RateTOS BIT TTLAudio GOPAlarm Alarm Notification IP ADDRESS/ALARM Notification Port NoCamera Site Alarm Video Loss AlarmALARM-DRY Contact CGI Reset Alarm OFF TimingTimer ALARM-CAMERA Site ON/OFFCGI Reset ALARM-VIDEO Loss CGI Reset RS-485 Data Port Baud RateData Stop BITDestination Setup Reference Setup FollowingsDestination IP Address in Receiving Packet Destination Port NoNetwork System Start UP Command NTP Server HOST/IP AddressTime Zone Daylight SavingsUser Administrator HostHost IP ADDRESS/ Subnet Mask Camera ControlMaintenance Firmware UpdateAccept Exclusive Command IP Address RestartHOW to Update the Firmware Camera Control Program Preset FocusIris DefrosterCamera Menu Control Settings Menus of the Decoder Top page of the decoderVideo page for each video output chan- nel DisplayReceiving Stream IP ADDRESS/RECEIVING Stream Port No Decode StateCH1 CH4 UNICAST/MULTICASTReceiving IP ADDRESS/RECEIVING Port No Decoder Start UP Setup Latency BufferDisplay Camera No. DisplayDate Display Display PositionCharacter Background Color YY/MM/DD hhmmss Year/Month/DayDD/MM/YY hhmmss Date/Month/Year Time DisplayEnter the IP address of the decoder Default setting is VIDEO&AUDIO Decryption Decryption KEY 4 Digits 0Device NAME/ LOCATION/CONTACT/ Snmp Community User Host Click to add a host after entering the host information HOW to Update the Firmware Troubleshooting SymptomNetwork troubles LINK1 indicator does not light ReferenceVideo troubles Are the IP addresses set correctly?Image is not displayed correctly Encoder may be downImage is disturbed drop frame, etc Audio fragmentation occurs No audioHOW to USE the CGI Commands Camera Control FormatResponse Item ListImportant Notices ExamplesCamera Settings Menus Control Important NoticeControl Item List Examples Switching Streaming Video Example Controlling Start /STOP of the Encoder Start encodingExamples Controlling Start / Stop of the Decoder Start decoding Streaming transmissionStop decoding Displaying the Status of the Encoder Http /1.1 Xxxxxxxxxxxxx CRExample Displaying the Status of the Decoder CrlfStatus of CH4 Controlling the BIT Rate of Streaming Video and Audio Data 101 Resetting the Alarm / Displaying the Alarm Status 103 Displaying the Contact Input Status Displaying the Status of Video Loss Muting the Audio Multiscreen Display Controlling the Contact Output PIOOUT Type109 Restarting the Encoder / Decoder Updating Default Settings Setting Default settingAudio Setup OFF ALARM-DRY Contact RESET/TIMER SEC60SEC Interval ALARM-CAMERA Site 60SEC Interval ALARM-VIDEO Loss114 No ChangeMulticast IP Address for Setup Multicast Port Latency Buffer None Decoder Start UP Setup DisplayTime Display Hour User User Authentication OFF User Name Device NameSpecifications Standard AccessoriesBasic Specification Input/Output117 118 N0603-1063 3TR001669BAB

WJ-GXD900, WJ-GXE900 specifications

The Panasonic WJ-GXE900 and WJ-GXD900 are top-tier video encoders designed to meet the increasing demands of surveillance applications. These devices are essential in providing high-quality video transmission over IP networks, making them ideal for both security and monitoring purposes.

One of the standout features of the WJ-GXE900 is its advanced encoding capability. It supports H.265 and H.264 compression standards, allowing for efficient bandwidth usage without compromising video quality. This technology is particularly beneficial for environments where bandwidth might be limited, as it significantly reduces the data load while maintaining impressive clarity, even in challenging lighting conditions.

The WJ-GXD900, on the other hand, is designed for high-definition video encoding. It also utilizes H.265 and H.264 technologies, but offers enhanced image processing capabilities. This includes advanced noise reduction, which helps to produce clearer images during low-light situations. Both models utilize 4K resolution support, allowing users to capture ultra-high-definition video, which is crucial for applications requiring detailed surveillance footage.

Another key characteristic of both models is their versatility in integration with IP cameras and other devices. They are compatible with a wide range of Panasonic and third-party IP cameras, ensuring that users can build a surveillance system tailored to their specific needs. This interoperability is vital for large installations where multiple camera types might be used.

The WJ-GXE900 and WJ-GXD900 also feature intuitive web-based interfaces, simplifying the setup and configuration processes. Users can easily manage settings, stream video, and monitor performance remotely from any device with internet access. This remote management capability is increasingly important in today's fast-paced environments, where quick responses and monitoring are critical.

Additionally, both models support multiple streaming options, including the ability to deliver video to various destinations simultaneously. This feature is particularly useful for organizations needing to distribute video feeds to multiple monitors or devices, enhancing real-time surveillance capabilities.

In conclusion, the Panasonic WJ-GXE900 and WJ-GXD900 are powerful video encoders that combine advanced technology with user-friendly features. Their support for high-quality video encoding, integration flexibility, and remote management capabilities make them excellent choices for any modern surveillance system. These devices exemplify Panasonic's commitment to innovation, reliability, and high-performance solutions in the realm of security technology.