Web setting screen

DDNS screen

Use DHCP to acquire the global IP address.

The DDNS function must be set in order to access the unit over the Internet.

When using the DDNS function, access the unit using the “address of host name.nmdns.net” which was registered in the DDNS server. To use the DDNS function, a connection with a dedicated DDNS server is required.

DDNS

Password [0 to 32 half-size characters]

<Initial setting: Off>

Whether the DDNS function is to be used is selected by setting “On” or “Off”.

<Initial setting: blank>

Input here the password for accessing the DDNS server.

Host name [1 to 64 half-size characters]

<Initial setting: blank>

Input here the host name to be used.

User name [1 to 32 half-size characters]

<Initial setting: blank>

Input here the user name (log-in name) for accessing the DDNS server.

Access interval

<Initial setting: 1h>

Select one of the settings below to be used as the access interval in which the IP address and host name are checked with the DDNS server.

1min

1 minute

 

 

10min

10 minutes

 

 

30min

30 minutes

 

 

1h

1 hour

 

 

6h

6 hours

 

 

24h

24 hours

 

 

71

Image 71
Contents AW‑HE50SN Contents WwConcerning the Operating Instructions Before useWwOverview WwAbout copyright and licence WwRequired personal computer environmentWwTrademarks and registered trademarks WwNetwork security WwDisclaimer of warrantyBasic shooting operations Select the shooting modeWhen the AW‑RP50 is connected How to turn the power on and offWwTurning the power on Set the Operate switch on the controller to onSet the Operate switch on the controller to OFF WwTurning the power offWwTypes of shooting modes Selecting the unitsSelecting the shooting modes scene files WwHow to select the shooting mode Press the OK button again Press the Menu buttonTurn the jog dial main Press the OK buttonQqChanging the camera’s direction QqUsing the zoom functionQqSwitching the direction or zoom speed ShootingMenu screen is displayed Lens focus is not adjusted automaticallyUnit does not move Multiple color bands color bars are displayedMore advanced operations Manual shooting WwManually adjusting the focusWwManually adjusting the iris Press the Shutter button and turn its lamp on WwManually adjusting the shutter speedPress the Gain button to turn off its lamp WwManually adjusting the gainPress the OFF, LOW or HI button Position may occur Preset memoriesHold down the Memory button Set to the memory recording modeSet the memory recording mode Hold down the Reset buttonWhen the AW‑RP555 is connected QqAutomatic adjustment AWB AWB A or AWB B White balance adjustmentWwWhite balance adjustment Press the AWC button Press the SET button for 2 secondsQqAuto tracking white adjustment ATW Press the IRIS - button Black level master pedestal adjustmentWwBlack level master pedestal adjustment Press the M/IRIS buttonPress the Iris button several times to turn off its lamp QqHorizontal phase adjustment Genlock adjustment AW‑HE50S onlyWwGenlock adjustment Press the Mode button QqColor phase adjustmentGenlock adjustment AW‑HE50S only Table of operations Basic operationsChanging Press the  or  button to change the setting Jog dial R Jog dial mainPress the Menu button for 2 seconds to exit the camera menu QqProcedure for camera menu operation AW‑RP655Mode button lights up at the BAR setting Press the Item button QqProcedure for camera menu operation AW‑RP555Press the Menu button of the AW‑RP555 for 2 seconds Perform one of the following steps to select the menu itemCamera OSD QqProcedure for camera menu operation AW‑RP50WwTop Menu Setting the menu itemsWwSetting the menu items WwCamera screen When Manual1 to 3 is selected WwCamera screen When FullAuto is selectedWwContrast screen WwPicture 1/2 screen WwSystem screen WwPicture 2/2 screenWwOutput screen WwGenlock screen AW‑HE50S onlyRGB-NOR Format unchanged screen QqChanging the formatFormat change check screen Format Set screenWwOther 1/2 screen OSD Off With Tally Off, On Tally Enable Disable, EnableWireless Control Disable, Enable WwOther 2/2 screenWwFirmware Version screen WwMaintenance screenInitialize screen Menu settings initialized screenMenu settings unchanged screen QqConcerning initializationMenu item table Menu Factory setting Selection items FullAutoWeb setting screen WwMenu operations Control Setup Power on button / Standby button  Control button / Setup button Zoom  Focus WwControl screen Brightness  Preset Control pad and its buttons  Basic button WwSetup screenQqBasic screen QqImage screen Image  Image Image adjustPreset position Image adjust screen  Scene FullAuto, Manual1, Manual2, Manual3  Contrast Contrast Mode Auto, ManualAWB  Picture Chroma Level -3 to +3Preset position setting screen  Preset  Zoom  Limitation Setting  Genlock AW‑HE50S only  Output ENH setting instead Other QqUser mng  Host check Host auth. screen  Host auth IP address QqServer IP address QqNetworkNetwork screen  IP network Port numbers already used 20, 21, 23, 25, 42, 53, 67, 68 Default gatewaySubnet mask  Host name 1 to 64 half-size characters  Password 0 to 32 half-size characters Access interval Ddns screen Contact 0 to 255 half-size characters Snmp screen Community 0 to 32 half-size characters  Location 0 to 32 half-size characters Time & date QqMaintenance Error description System log screenClick the Execute button Upgrade screenEnter the software version in the xxxxx part  Reset to the default and load the default Html files Default reset screen Reset to the default Except the network settings  Load the default Html files setup menu Upload Back up screen Download Other screen Category Display Description of error DDNS-related error displaysNTP-related error displays Login-related displaysLimiters Press one of the CAM1 to CAM4 buttons to select the unit Setting/releasing the limitersWwSetting the limiters WwBasic limiter operationsPp Releasing the lower limit position of the movement range WwResetting the limitersWwReleasing the limiters Pp Releasing the upper limit position of the movement rangeTrouble-triggered safe mode Safe modeWwConcerning the safe mode CPU WwSystem requirements for a PCSolution WwPrecautions when using Windows VistaSymptom Symptom QqRestrictions Restriction When activating audio on the web browserWwPrecautions when using Windows Restriction 2 When using Windows 7 with some products Restriction 1 On the setup pages for some productsPanasonic Solutions Company
Related manuals
Manual 90 pages 20.69 Kb

AWHE50HN specifications

The Panasonic AW-HE50HN is a state-of-the-art PTZ (Pan-Tilt-Zoom) camera designed for professional video production and broadcasting. This versatile camera is favored for its compact design and advanced features, making it an excellent choice for a variety of applications such as live events, education, houses of worship, and corporate environments.

One of the primary highlights of the AW-HE50HN is its impressive imaging capabilities. Equipped with a 1/2.3-inch sensor, it delivers high-definition video quality up to 1080p with a remarkable dynamic range. The camera features a powerful 20x optical zoom lens that allows users to capture distant subjects with clarity while maintaining the quality of the image. This feature is particularly valuable in large venues where the camera might be located far from the action.

The AW-HE50HN also stands out for its superb low-light performance. With a minimum illumination requirement of just 1.6 lux in color mode and 0.3 lux in black and white mode, this camera excels in dimly lit environments, ensuring that every important moment is recorded in high detail.

Networking capabilities are another key aspect of the AW-HE50HN. It supports various streaming protocols, including RTSP and RTMP, allowing for seamless integration into existing networks. This feature makes it ideal for live streaming events directly to the web or for remote monitoring via IP networks. Additionally, the camera can be controlled remotely, offering great flexibility for operators managing multiple cameras during broadcasts.

In terms of usability, the AW-HE50HN is designed with real-time control in mind. It includes multiple control interfaces such as RS-232, RS-422, and LAN, giving operators the freedom to choose the best method for their setup. The camera’s robust built-in protocols ensure compatibility with a variety of third-party controllers, making it a versatile addition to any video production setup.

The AW-HE50HN also boasts a number of special features, including face detection technology and various image stabilization options, which help enhance production quality. Its compact and lightweight design allows for easy installation in any environment, whether it's mounted on a wall, placed on a tripod, or integrated into a more complex studio setup.

In conclusion, the Panasonic AW-HE50HN is a sophisticated and adaptable camera that combines advanced imaging technology with versatile connectivity and remote control options. Its ability to deliver high-quality video in diverse lighting conditions, along with its ease of integration into video production workflows, makes it a preferred choice for professionals in the field. Whether for broadcasting, live events, or corporate use, the AW-HE50HN stands out as a reliable and powerful solution.