Zebra Technologies S-300 Initial Printer Test, Configuration and Calibration, Switch Baud Rate

Page 21

Getting Started

Initial Printer Test

To insure proper sensing of the media and ribbon, perform a Media Calibration. This procedure establishes the media parameters for the printer. If loading the printer with media and ribbon for the first time, or changing the type of media, perform the Media Calibration on page 14.

1

Configuration and Calibration

Option Switches (Only for Serial-Interface Printers)

Note: A printer with a parallel interface does not require these configuration parameters and therefore has no switches.

A printer with the RS-232 serial interface has eight miniature switches, which are located inside the rear access opening above the Signal Interface Cable Connector.

You need to position these switches to match the settings of your host computer in order to establish communications between the two devices. If you do not know how to determine the settings on your host computer, refer to the directions in the instruction manual provided with the computer.

If these switches are in the proper position to match the communication configuration of the host computer, and the printer is not receiving data, see the Appendix to make sure you are using the correct interface cable.

Figure 10 Option Switches

Option Switch Settings

An “R” means the switch is OFF (positioned to the right), while an “L” means the switch is ON (positioned to the left). Zebra sets all switches to OFF when the printer is manufactured.

Switch

Baud Rate

3

2 1

 

 

 

R R R

9600 Baud

R R L

19200 Baud

R L R

110 Baud

R L L

300 Baud

L R R

600 Baud

L R L

1200 Baud

L L R

2400 Baud

L L L

4800 Baud

Switch

Data Bits

 

4

(Must be set to 8 data bits for

 

 

Code Page 850.)

 

 

R

7 Data bits

L

8 Data bits

Switch

Parity

6 5

 

 

 

R R

Even parity

R

L

Parity disabled

L R

Odd parity

L

L

Parity disabled

Switch

Communication Handshake

 

7

Control

 

 

R

XON/XOFF control

L

DTR/DSR control

 

 

 

13

Image 21
Contents User’s Guide Proprietary Statement Warranty Information Zebra Software License Agreement Warranty InformationMedia Calibration Adjust the Print Darkness AC Power ON/OFF Switch Fro FEEDServicesKey and Pause Key RS-232 Cabling Requirements Reporting Damage UnpackingGetting Started Printer Power UpSite Requirements Storage and ReshippingVoltage Selection AC Power CableCommunications T t i n g S t a r t e d Tear- Off Mode Media LoadingMedia and Ribbon Loading MediaCutter Mode Media Loading Cutter Option Required External Rewind Mode Media LoadingFanfold Media Loading Fanfold Media Loading in Tear-Off Mode Peel-Off Mode Media LoadingPeel-Off Option Required Removing the Label Backing Material Peel Off Option Required Adjusting the Media Sensor Non-Continuous MediaContinuous Media Ribbon Loading Adjusting the Ribbon Supply SpindleRibbon Supply Spindle Normal Position Ribbon Supply Spindle Low-Tension PositionLoading the Ribbon Ribbon RemovalOption Switch Settings Configuration and CalibrationSwitch Baud Rate SwitchMedia Calibration Configuration ModeAdjust the Print Darkness Adjust the Media Rest PositionAdjust the Position of the Top of the Label Getting Started Tear-Off Mode Operating Your Zebra Stripe PrinterPrinter Operating Modes AC Power ON/OFF Switch OperationOperator Controls AC Power ON/OFF Switch Front Panel Keys Front Panel LightsSensor What it monitors How it works Printer Status SensorsBacking Rewind Spindle Full Sensor Position Sample ZPL II Label Formats Format 1 Simple Text and a BarcodeType this label format Format 2 Saving a Label Format As a Graphic Image Format 3 Using a Serialized Data FieldLine Type this label format You’ll get this printout Type this label format You’ll get this printoutCleaning the Exterior CleaningCleaning the Interior Preventive Maintenance KitCleaning the Printhead Routine Care and AdjustmentCutter Module and Catch Tray Location This procedure is on the next Cutter Module Disassembly This procedure is on Reassembled Cutter Module Lubrication AC Power Fuse ReplacementPrint Quality Adjustments Mechanical AdjustmentsToggle Pressure Adjustment Toggle Pressure AdjustmentRibbon Supply Spindle Adjustment Media Sensor Position AdjustmentBattery Replacement Troubleshooting Table Troubleshooting and DiagnosticsFlashing Troubleshooting and DiagnosticsTroubleshooting and Diagnostics Troubleshooting and Diagnostics Printer Diagnostics Power-On Self TestAdditional Printer Self Tests Pause Key Self Test Cancel Key Self TestPause Key Self Test Printout Feed Key Self TestExtended Printer Diagnostics Mode Key Self TestFeed Key and Pause Key Page Page Options*Factory-Installed StandardPrinterFonts DefaultPrinterFonts6Dots/mm Page Ard BitmapSmoothFontsPointSizeExamples Zebra Technical Support Bulletin Board Service How to Reach UsTechnical Support Zebra’s Corporate OfficesSupport Services Technical Support Service via TelephoneTechnical Support via Mail or Fax Zebra Technologies Corporation Service Form Extended Factory Service Agreement Product Service and Support ProgramsThird Party Support And Maintenance Select The Program That Fits Your BusinessZebra Factory Services User Self MaintenanceWang Customer Services Division International Service and Support Zebra Training Programs Course Name Printers Covered Operations and Maintenance CoursesLabeling Bar Codes at WorkSupport Services Printhead Position Adjustment Procedure Adjusting the PrintheadAppendix Print Quality AdjustmentHardware Control Signal Descriptions Signal LevelsPrinter Interface Technical Information RS-232 InterfaceRS-232 Cabling Requirements Interconnect To DTE DevicesInterconnect To DCE Devices Parallel Cabling Requirements Parallel InterfacePin No Parallel Connector Pinout Signal DescriptionsGlossary Glossary Index Index