Zebra Technologies RW 220, RW 420 manual Charging process per the following table

Page 18

the charging process per the following table:

UCLI72-4Battery Status Indicators

 

Amber LED

Green LED

Battery Status

 

 

 

 

 

 

 

On

Off

Charging

 

 

On

Flashing

80% charged (O.K. to use)

 

 

Off

On

Completely Charged

 

 

Flashing

Off

Fault

 

 

 

 

 

 

 

 

 

 

 

Important • A fault condition is caused by a problem with the battery. The charger may indicate a fault because the battery is too hot or too cold to charge reliably. Try to charge the battery again when it returns to the room’s ambient temperature. If the Amber indicator starts flashing on the second charging attempt, the battery should be discarded. Always dispose of batteries in a proper manner. Refer to Appendix E

LI72-4 Charger Cycle Times :

RW 420

RW 220

Battery 80% Charged

2.5 Hrs.

1.25 Hrs..

 

 

 

 

 

Battery Fully Charged

5 Hrs..

2.5 Hrs..

 

 

 

 

 

 

 

 

 

Note • Charge times are for completely discharged batteries.

Partially discharged Battery Packs will take less time than listed in the chart to reach a fully charged state. Once Battery Packs have reached 80% of their charge capacity they may be used, but it is recommended that you allow the batteries to reach a full charge to maintain maximum battery life.

Note • The UCLI72-4 Quad Charger’s safety features will stop the battery charging process after six hours regardless of the battery’s charge state.

18

RW Series User Guide

Image 18
Contents UMAN-RWS-010 Rev. B May Contents Extending Battery Life General Cleaning Instructions Magnetic Stripe Reader Smart Card ReaderRW Series User Guide Proprietary Statement Product ImprovementsAgency Approvals and Regulatory Information Document Conventions RW 420 Overview RW 220 Overview Introduction to the RW Series Unpacking and InspectionReporting Damage Battery Safety Charger SafetyGetting Ready to Print Installing the RW 420 Battery LI72 Charger Installing RW Series BatteriesLI72 Charger Charger JackLI72 Single Charger Types Indicator Charger Charger Status Function Charging Battery Contact ProblemGreen Solid Fully Charged Short Circuit of Output TerminalsModel UCLI72-4 Quad Charger Power SupplyPower Indicator AmberBattery 80% Charged Hrs 25 Hrs Battery Fully Charged Charging process per the following tableMedia Compartment Loading Media ProcedureLoading the Media Media SupportLoading Media From An Internal Supply Media RollLoading Media From An External Supply Media SpacerBA16625-1 Closing the Media Cover Operator Controls Control PanelProgrammable LCD Settings Extended LCD Functions1 Display Functions Not Accessible from the Keypad1 Printing a Configuration Label Verify the Printer Is WorkingSerial RS232C and USB Combination Port Connecting the PrinterCable Communications USB Port RS232/USB PortPrinter Communications Port Cable Communications CableRS232 Communications Cable Wireless Communications Wireless Communications with BluetoothBluetooth Networking Overview Wireless Local Area Network Overview Setting Up the Software Bluetooth RW -ZBR3 Radio RW 220 and RW Radio Regulatory InformationZebra Bluetooth Radio 2.0 RW-ZBR4 RW 220 and RW Compact Flash 802.11b Radio Module Europe EU Declaration of Conformity Zebra Value Radio, 802.11b Europe EU Declaration of Conformity Wlan Module Using 802.11b/g Radio Industry Canada IC Warning004 Europe EU Declaration of Conformity 주로 가정에서 사용하는 것을 목적으로 하며, 모든 지역에서 사용할 수 있습니다 Compact Flash 802.11b and Bluetooth Co-located Radio Modules RW Series User Guide Rdr indicates MSR is enabled Card Reader OptionsMagnetic Stripe Reader Magnetic Stripe Card Magnetic Stripe Reader SlotSmart Card Reader Using the Accessories Belt ClipClip printer to belt Printer can pivot freely Adjustable Shoulder Strap Using the Shoulder StrapNormal Display Cradle Installing the RW 420 in the CradleCradles Display rotated CradleCharge Power Indicator IndicatorRemoving the RW 420 from the Cradle RW 220 Vehicle Cradle Refer to FigureRemoving the RW 220 from the Cradle Preventive Maintenance Extending Battery LifeGeneral Cleaning Instructions Cleaning RW Series Printers Troubleshooting LCD Control Panel IndicatorsTroubleshooting Topics No powerFlashing or icon Troubleshooting Techniques Communications DiagnosticsPerforming a Forced Shutdown Calling Technical Support Wireless options Installed softwareSettings for InstalledConfiguration Label Example Configuration Label Example Specifications Printing SpecificationsMemory/Communications Specifications RW 420 Media Specifications RW 220 Media SpecificationsCommunication Ports Combination PortCommunications Ports USBFont/Bar Code Specifications UCC/EANPhysical/Environmental/Electrical Specifications RW 420 Overall Dimensions 94 mm max 81 mm Max 175 mm 160 mm 188 mm185.3 mm 111.8 mm 173.6 mm 99.1 mm94.1 mm1 81 mm1 # 6-32 x Mm deep Places RW Series Accessories USB Download Cable Appendix aInterface Cables RS232 Download Cable Part Number AK17463-008 RW Mod Plug to 9-Pin DB PC CableMore Interface Cables USB Cable Part Number AT17010-1 USB a to USB Mini B CableAppendix B Media SuppliesMaintenance Supplies Appendix CAmericas contact Appendix DProduct Support Europe, Africa, the Middle East, and India contactCode Product ConfigurationProduct Serial NumberBattery Disposal Appendix EProduct Disposal Select printer model e.g. RW Using zebra.comAppendix F Select languageClick on Software & Utilities tab to download Label Vista Index Magnetic Stripe Reader 43 Smart Card ReaderBluetooth radio ZBR3 & QL+ZBR4 802.11b Compact Flash radio 34,?36Patent Numbers 201,255 B1