Nortel Networks 8010co manual Office alarm connectors J3 and J4

Page 77

Appendix B BIP external cable pin assignments 77

Office alarm connectors (J3 and J4)

The BIP office alarm connectors (J3 and J4) use high-density, 26-pin D-sub connectors (Figure 47).

Figure 47 J3 and J4 high-density 26-pin D-sub connector

19 26

1 9

10438EA

Figure 48 shows the pinouts for the J3 and J4 office alarm connectors.

Figure 48 J3 and J4 office alarm connectors

BIP 1

J3/J4

 

TTA

1

TRB

2

D2A

3

SPARE1B

4

SPARE3A

5

SPARE4B

6

Not used

7

Not used

8

Not used

9

AISALM2

10

TTB

11

D1A

12

D2B

13

SPARE2A

14

SPARE3B

15

SPARE5A

16

Not used

17

Not used

18

AISALM1

19

TRA

20

D1B

21

SPARE1A

22

SPARE2B

23

SPARE4A

24

SPARE5B

25

Not used

26

P3/P4

P3/P4

1

1

2

2

3

3

4

4

5

5

6

6

7

7

8

8

9

9

10

10

11

11

12

12

13

13

14

14

15

15

16

16

17

17

18

18

19

19

20

20

21

21

22

22

23

23

24

24

25

25

26

26

 

External cable (not supplied)

J3/J4

BIP 2

1 TTA

2 TRB

3 D2A

4 SPARE1B

5 SPARE3A

6 SPARE4B

7 Not used

8 Not used

9 Not used

10 AISALM2

11 TTB

12 D1A

13 D2B

14 SPARE2A

15 SPARE3B

16 SPARE5A

17 Not used

18 Not used

19 AISALM1

20 TRA

21 D1B

22 SPARE1A

23 SPARE2B

24 SPARE4A

25 SPARE5B

26 Not used

10439EA

Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis

Image 77
Contents Part No -G Rev May Great America Parkway Santa Clara, CA Trademarks Copyright 2006 Nortel Networks. All Rights ReservedStatement of conditions International regulatory statements of conformityVcci statement Japan/Nippon only CE marking statement Europe onlyEN 60 950 statement Nortel Inc. software license agreementGeneral Rev Contents Rev ContentsIndex Contents Rev Figures Rack grounding strip example Tables Tables Rev Before you begin PrefaceText conventions How to get HelpGetting Help from the Nortel Web site PrefaceGetting Help through a Nortel distributor or reseller Getting Help over the phone from a Nortel Solutions CenterPreface Rev Physical description Chapter OverviewOverview Front panelShelf circuit breakers upper and lower shelves Shelf circuit breakers Alarm module display LEDs Alarm module display panelMajor Front panel locking screws Shelf alarm connectors upper and lower shelvesBack panel Shelf alarm connections upper and lower shelves Configuring multiple BIPs to aggregate office alarms Central office alarmsConfiguring standalone BIPs to report alarm status Power terminal block1 3 2 1 3 2 1 a 1 a 2 B 1 B Power and grounding example Opening the front panel Accessing the alarm moduleAccessing the alarm module 8010co chassis configuration with BIP option Configuration examplePreparing to install the breaker interface panel Chapter InstallationShipment contents Additional equipment DC power requirementsMounting hardware DC input electrical requirementsInstalling the hardware Installing the breaker interface panelRemoving the plastic back cover from the BIP Connecting cables to the chassis power supplies Removing the 8010co chassis bottom 312096-A bezel Location of power supplies Loosening the power supply retaining screws +DC -DC Power supply cables Attaching the positive lead +DC -DC Replacing the power supply Labeling cables for the BIP Routing power supply cables to the BIPRack grounding strip example Connecting the ground cables to the rack grounding stripAttaching power supply cable leads to the BIP Connecting the power supply cables to the BIPLocate the BIP ground cable see on Attaching the BIP ground cable Connecting DC input power feeds to the BIP Single chassis and dual chassis input options B feed exampleLocating the a and B -48 VDC input feeds Connecting the a and B -48 VDC input feeds to the BIP 1 Connecting the a and B -48 VDC input feeds to the BIP 2 Connecting the A/B input feed returns 1 Go to the next section, Replacing covers on Replacing the plastic back cover on the BIP Replacing coversGo to the next section, Installing shelf alarm cables on Installing shelf alarm cables Installing shelf alarm cablesVerifying the installation Verifying the LEDs Initial power-upPowering off the system Installation Installation Rev Chapter Problem solving Interpreting the LEDs Problem solvingOr a problem in circuits that are not essential to Diagnosing and correcting the problem Corrective actions Corrective actionsProblem solving Corrective actions Environmental Appendix a Technical specifications Safety agency certification Physical dimensions Appendix a Technical specifications ElectricalAppendix B BIP external cable pin assignments Shelf alarm connectors J1 and J2Appendix B BIP external cable pin assignments J1 and J2 shelf alarm connector pin assignmentsJ3 and J4 high-density 26-pin D-sub connector Office alarm connectors J3 and J4J3 and J4 office alarm connector pin assignments J5 high-density 26-pin D-sub connector Standalone office alarm connector J5J5 standalone office alarm connector pin assignments Numbers IndexIndex