Appendix B BIP external cable pin assignments 79
Standalone office alarm connector (J5)
The standalone office alarm connectors (J5) uses a
Figure 49 J5 high-density 26-pin D-sub connector
19 26
1 9
10438EA
Figure 50 shows the pinouts for the J5 standalone office alarm connector.
Figure 50 J5 standalone office alarm connector
BIP | J5 |
Critical alarm, Visual (NC) 1
Major alarm, Visual (NC) 2
Minor alarm, Visual (NC) 3
Critical alarm, Audible (NC) 4
Major alarm, Audible (NC) 5
Minor alarm, Audible (NC) 6
External alarm (NC) 7
Not used 8
Not used 9
Critical alarm, Visual (COM) 10
Major alarm, Visual (COM) 11
Minor alarm, Visual (COM) 12
Critical alarm, Audible (COM) 13
Major alarm, Audible (COM) 14
Minor alarm, Audible (COM) 15
External alarm (COM) 16
Not used 17
Not used 18
Critical alarm, Visual (NO) 19
Major alarm, Visual (NO) 20
Minor alarm, Visual (NO) 21
Critical alarm, Audible (NO) 22
Major alarm, Audible (NO) 23
Minor alarm, Audible (NO) 24
External alarm (NO) 25
Not used 26
P5
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
Central office device
External cable (not supplied) | 10440EA |
|
Installing the Breaker Interface Panel for the Ethernet Routing Switch 8010co Chassis