Nortel Networks R2MFC manual Argentina Config, Interpretation of transmitted MFC signals

Page 102

102Configuring DIP switch settings and definitions

Table 38 Interpretation of received MFC signals (Sheet 2 of 2)

Meaning

Signal

Meaning

Signal

Meaning

Signal

Meaning

Signal

 

 

 

 

 

 

 

 

FW_Digit_8

I_8

FW_Categ_8

II_8

BW_Prev3Digit

A_8

BW_B_Congest

B_8

 

 

 

 

 

 

 

 

FW_Digit_9

I_9

FW_Categ_9

II_9

BW_PrevDigit

A_9

BW_B_Congest

B_9

 

 

 

 

 

 

 

 

FW_Digit_0

I_10

FW_Categ_10

II_10

BW_Illegal

A_10

BW_B_Congest

B_10

 

 

 

 

 

 

 

 

FW_Digit_11

I_11

FW_Categ_11

II_11

BW_Illegal

A_11

BW_B_Congest

B_11

 

 

 

 

 

 

 

 

FW_ReqFault

I_12

FW_Categ_12

II_12

BW_Illegal

A_12

BW_B_Congest

B_12

 

 

 

 

 

 

 

 

FW_Digit_13

I_13

FW_Categ_13

II_13

BW_Illegal

A_13

BW_B_Congest

B_13

 

 

 

 

 

 

 

 

FW_Digit_14

I_14

FW_Categ_14

II_14

BW_Illegal

A_14

BW_B_Congest

B_14

 

 

 

 

 

 

 

 

FW_EndDigits

I_15

FW_Categ_15

II_15

BW_Illegal

A_15

BW_B_Congest

B_15

 

 

 

 

 

 

 

 

Table 39 Interpretation of transmitted MFC signals

Meaning

Signal

Meaning

Signal

Meaning

Signal

 

 

 

 

 

 

BW_NextDig

A_1

FW_EndANIdgts

I_15

FW_Categ_2

II_2

 

 

 

 

 

 

BW_BCateg

A_3

FW_Digit_1

I_1

FW_Categ_3

II_3

 

 

 

 

 

 

BW_RtrnToA

A_1

FW_Digit_2

I_2

FW_Categ_4

II_4

 

 

 

 

 

 

BW_A_Congest

A_4

FW_Digit_3

I_3

FW_Categ_5

II_5

 

 

 

 

 

 

BW_B_Congest

B_4

FW_Digit_4

I_4

FW_Categ_6

II_6

 

 

 

 

 

 

BW_Category

A_5

FW_Digit_5

I_5

FW_Categ_7

II_7

 

 

 

 

 

 

BW_SpeechChrg

NO_SG

FW_Digit_6

I_6

FW_Categ_8

II_8

 

 

 

 

 

 

BW_OrigDn

A_5

FW_Digit_7

I_7

FW_Categ_9

II_9

 

 

 

 

 

 

BW_FreeCharge

B_1

FW_Digit_8

I_8

FW_Categ_10

II_10

 

 

 

 

 

 

BW_FreeNoChrg

B_5

FW_Digit_9

I_9

FW_Categ_11

II_11

 

 

 

 

 

 

BW_CntrCharge

B_1

FW_Digit_0

I_10

FW_Categ_12

II_12

 

 

 

 

 

 

BW_Busy

B_2

FW_Digit_11

I_11

FW_Categ_13

II_13

 

 

 

 

 

 

BW_Unlocated

B_7

FW_Digit_12

I_12

FW_Categ_14

II_14

 

 

 

 

 

 

BW_OutOfOrder

B_4

FW_Digit_13

I_13

FW_Categ_15

II_15

 

 

 

 

 

 

BW_ChangOrder

B_4

FW_Digit_14

I_14

FW_KD_Local

II_3

 

 

 

 

 

 

FW_ReqFault

I_12

FW_Digit_15

I_15

FW_KD_LnDst

II_2

 

 

 

 

 

 

FW_EndDigits

I_15

FW_Categ_1

II_1

 

 

 

 

 

 

 

 

Argentina Config 1

E1 Physical Characteristics

Connector type: BNC

Line coding: HDB3

NN40010-300

Image 102
Contents R2MFC Media Bay Module Installation and Configuration Guide Safety North American Regulatory InformationEnhanced 911 Configuration R2MFC Media Bay Module Installation and Configuration GuideRadio-frequency Interference Repairs Important Safety InstructionsHearing Aid Compatibility NN40010-300International Regulatory Information NN40010-300 Contents Chapter Preparing to install the R2MFC MBM Chapter R2MFC MBM maintenance Appendix a Configuring DIP switch settings and definitions MFC Register Signaling Panama Config 1 NN40010-300 Getting Help from the Nortel Web site How to Get HelpGetting Help over the phone from a Nortel Solutions Center Getting Help through a Nortel distributor or resellerHow to Get Help NN40010-300 Getting started About this guideAudience Before you begin AcronymsSymbols and text conventions Pswd Convention Example Used forRelated publications Getting started NN40010-300 Chapter Overview General informationAdministration and maintenance tools R2MFC MBM faceplate elementsOverview Config DIP switches System Status LEDsRS232 port BNC and RJ-48 connectorsR2MFC MBM back and underside elements E1 Status LEDsPower connectors MBM DIP switchesOverview NN40010-300 Chapter Preparing to install the R2MFC MBM Preparing to install the R2MFC MBM Installation process mapHost system setup requirements Host system setup requirementsR2MFC MBM setup requirements Config DIP switchesCustomer supplied hardware requirements Chapter Installing the R2MFC MBM Overview of the R2MFC MBM installationInstalling the R2MFC MBM Shutting down the systemShutting down a BCM 4.0 system Shutting down a BCM 3.7 or lower system Shutting down the BCM 4.0 system hardwareInstalling an R2MFC MBM Installing an R2MFC MBM in the BCM platform base chassisInstalling an R2MFC MBM in the expansion unit Installing an R2MFC MBM in the BCM50 expansion unit Installing the rubber boot in an R2MFC moduleR2MFC Transmit Co-axial cable connected to the MBM Reconnecting the equipment Removing an R2MFC MBMHow to remove a BCM200 R2MFC MBM Removing an R2MFC MBM from the BCM platform base chassisHow to remove a BCM400 R2MFC MBM Removing an R2MFC MBM from the expansion unitWiring an R2MFC MBM How to remove the expansion unit front bezelInstalling the R2MFC MBM Connecting an R2MFC MBM to a service provider Trunk wiring overviewInstalling the R2MFC MBM Chapter Configuring the R2MFC MBM Configuring the R2MFC MBMMFCR2 side External Link configurable parameters Physical line characteristicsE1 framing Line signaling Register signalingMinimum or fixed number length + timer parameters Option Parameters Meaning DefaultConfiguring the MFCR2 external link Setting Config DIP switchesConfig DIP switch layout Creating a customized country codePRI side Internal Link configurable parameters E1 framing default parametersConfiguring the PRI internal link using Element Manager Configuring the PRI internal linkSignaling Layer 2 signaling parametersModule configuration parameters Parameter SettingConfiguring the PRI internal link using Unified Manager BCM lines configuration for R2MFC MBMModule type BCM module configuration for R2MFC MBM Off Turning on second dial tone using Element Manager Turning on second dial toneTurning on second dial tone using Unified Manager Outgoing dialing configuration for second dial toneConfiguring the R2MFC MBM Chapter R2MFC MBM maintenance Inter-working functionalityR2MFC MBM maintenance Clock synchronizationTranslation of Subscriber Status Diagnostic and loopback modes Diagnostic toolsSetting the R2MFC MBM to diagnostic mode Mode Description Call AvailabilityAlarms Alarms MeasurementsGroup I Alarms propagation Sheet 1 Alarms propagationIncoming signal errors Alarm CauseFaceplate LEDs R2MFC MBM maintenance Group I Alarms propagation Sheet 2Group II alarms propagation System status monitor LEDsLED Name Yellow LED Error messagesLogs and traces Red LEDOverview of module replacement process Replacing an R2MFC MBMUpgrading firmware Hyper-terminal setup parameters Connect usingProgram responds starting rec 0. Hit any key to continue R2MFC MBM maintenance NN40010-300 Chapter Command Line Interface CLI Users and passwordsOverview Accessing the CLI Command Line Interface CLIINfo directory CLI commands CommandsLOad directory CLI commands LOad directoryVIew directory CLI commands VIew directoryCNtrl directory CLI commands Sheet 1 CNtrl directoryNN40010-300 COnfig directory CNtrl directory CLI commands Sheet 3COnfig directory CLI commands Sheet 1 NN40010-300 ALarm directory ALarm directory CLI commands Sheet 1NN40010-300 SWerr directory CLI commands SWerr directoryMFC directory CLI commands Sheet 1 MFC directoryMFC directory CLI commands Sheet 2 See Chapter , MFC Signal Definitions, on page 111 for MFC R2 directory CLI commands Sheet 1 R2 directoryCommand Line Interface CLI R2 directory CLI commands Sheet 2 PRI directory CLI commands PRI directoryCommand Line Interface CLI NN40010-300 Appendix a Configuring DIP switch settings and definitions Shows the Config DIP switch layoutCountry selection DIP switch settings Second dial tone DIP switch settingsCountry code defaults Mexico ConfigMexico Config 1 R2 A/B signals Interpretation of received MFC signals Interpretation of transmitted MFC signals Sheet 1Meaning Signal Mexico Config Mexico Config 2 R2 A/B signals Interpretation of received MFC signals Sheet 1Interpretation of transmitted MFC signals Brazil Config Brazil Config 1 R2 A/B signalsInterpretation of received MFC signals Brazil Config Brazil Config 2 R2 A/B signals Argentina Config Argentina Config 1 R2 A/B Signals Interpretation of received MFC signals Chile Config Chile Config 1 R2 A/B signalsSignal Block Panama Config Configuring DIP switch settings and definitions NN40010-300 Appendix B Diagnostic and loopback DIP switch settings Diagnostics and Loopback Dip Switch SettingsDiagnostic and loopback DIP switch settings NN40010-300 Appendix C MFC Signal Definitions MFC signal definitionsMFC signal meaning MFC Signal Definitions NN40010-300 Appendix D CLI Cable Pinout Cable pinoutsCLI Cable Pinout NN40010-300