Nortel Networks R2MFC manual Minimum or fixed number length + timer parameters

Page 48

48 Chapter 5 Configuring the R2MFC MBM

End of dialing (incoming)

End of dialing for an incoming call can be configured by using the CLI. See Table 3, for the end of dialing options.

Table 3 Minimum (or fixed) number length + timer parameters

Option

Parameters

Meaning

Default

 

 

 

 

Explicit ‘End of dial’ signal

None

The preset option for all

Yes

(I-15)

 

countries. However, signal

 

 

 

has low significance, because

 

 

 

the end of dialing is

 

 

 

determined by the BCM (PRI

 

 

 

side) when it receives the last

 

 

 

digit of the number.

 

 

 

 

 

Minimum (or fixed) number

Minimal number of digits

Receiving minimum number of

No

length and timer

 

digits + optional number of

 

 

 

digits means end of dial

 

Minimum (or fixed) number

Optional number of additional

No

(maximum length reached)

length and timer

digits

 

When a fixed length number is

 

 

 

 

 

 

always expected, set the

 

 

 

optional number of digits to 0.

 

 

 

 

 

Minimum (or fixed) number

Interdigit timer in the minimal

Expiry of the long timer means

No

length and timer

interval (long timer)

MFC error - number

 

 

 

incomplete.

 

 

 

 

 

Minimum (or fixed) number

Interdigit timer in the optional

Expiry of the short timer

No

length and timer

interval (short timer)

means end of dial.

 

 

 

 

 

End of dialing (outgoing)

End of dialing in outgoing calls is indicated by MFC signal “I15” (or equivalent country-specific signal). This signal is sent if the far-end requests next digit beyond the last digit of the dialed number.

When R2MFC MBM originates a call to the CO, the R2MFC MBM has already received the whole dialed number from the BCM. This is because the digits are passed from BCM to the MBM by PRI “en-bloc.” This operation mode means that BCM determines user end-of-dialing either by number of digits, explicit input from user (for example, the “#” digit), or timeout.

Disable ANI

The ANI request option can be disabled. When disabled:

Incoming call — R2MFC MBM does not request ANI.

Outgoing call — When far end requests ANI, R2MFC MBM answers “ANI not available.”

NN40010-300

Image 48
Contents R2MFC Media Bay Module Installation and Configuration Guide Safety North American Regulatory InformationEnhanced 911 Configuration R2MFC Media Bay Module Installation and Configuration GuideRadio-frequency Interference Important Safety Instructions Hearing Aid CompatibilityRepairs NN40010-300International Regulatory Information NN40010-300 Contents Chapter Preparing to install the R2MFC MBM Chapter R2MFC MBM maintenance Appendix a Configuring DIP switch settings and definitions MFC Register Signaling Panama Config 1 NN40010-300 How to Get Help Getting Help over the phone from a Nortel Solutions CenterGetting Help from the Nortel Web site Getting Help through a Nortel distributor or resellerHow to Get Help NN40010-300 Getting started About this guideAudience Before you begin AcronymsSymbols and text conventions Pswd Convention Example Used forRelated publications Getting started NN40010-300 Chapter Overview General informationAdministration and maintenance tools R2MFC MBM faceplate elementsOverview Config DIP switches System Status LEDsBNC and RJ-48 connectors R2MFC MBM back and underside elementsRS232 port E1 Status LEDsPower connectors MBM DIP switchesOverview NN40010-300 Chapter Preparing to install the R2MFC MBM Installation process map Host system setup requirementsPreparing to install the R2MFC MBM Host system setup requirementsR2MFC MBM setup requirements Config DIP switchesCustomer supplied hardware requirements Chapter Installing the R2MFC MBM Overview of the R2MFC MBM installationInstalling the R2MFC MBM Shutting down the systemShutting down a BCM 4.0 system Shutting down a BCM 3.7 or lower system Shutting down the BCM 4.0 system hardwareInstalling an R2MFC MBM Installing an R2MFC MBM in the BCM platform base chassisInstalling an R2MFC MBM in the expansion unit Installing an R2MFC MBM in the BCM50 expansion unit Installing the rubber boot in an R2MFC moduleR2MFC Transmit Co-axial cable connected to the MBM Reconnecting the equipment Removing an R2MFC MBMHow to remove a BCM200 R2MFC MBM Removing an R2MFC MBM from the BCM platform base chassisHow to remove a BCM400 R2MFC MBM Removing an R2MFC MBM from the expansion unitWiring an R2MFC MBM How to remove the expansion unit front bezelInstalling the R2MFC MBM Connecting an R2MFC MBM to a service provider Trunk wiring overviewInstalling the R2MFC MBM Chapter Configuring the R2MFC MBM Configuring the R2MFC MBMMFCR2 side External Link configurable parameters Physical line characteristicsE1 framing Line signaling Register signalingMinimum or fixed number length + timer parameters Option Parameters Meaning DefaultConfiguring the MFCR2 external link Setting Config DIP switchesConfig DIP switch layout Creating a customized country codePRI side Internal Link configurable parameters E1 framing default parametersConfiguring the PRI internal link SignalingConfiguring the PRI internal link using Element Manager Layer 2 signaling parametersModule configuration parameters Parameter SettingConfiguring the PRI internal link using Unified Manager BCM lines configuration for R2MFC MBMModule type BCM module configuration for R2MFC MBM Off Turning on second dial tone using Element Manager Turning on second dial toneTurning on second dial tone using Unified Manager Outgoing dialing configuration for second dial toneConfiguring the R2MFC MBM Chapter R2MFC MBM maintenance Inter-working functionalityR2MFC MBM maintenance Clock synchronizationTranslation of Subscriber Status Diagnostic tools Setting the R2MFC MBM to diagnostic modeDiagnostic and loopback modes Mode Description Call AvailabilityAlarms Alarms MeasurementsAlarms propagation Incoming signal errorsGroup I Alarms propagation Sheet 1 Alarm CauseR2MFC MBM maintenance Group I Alarms propagation Sheet 2 Group II alarms propagationFaceplate LEDs System status monitor LEDsError messages Logs and tracesLED Name Yellow LED Red LEDOverview of module replacement process Replacing an R2MFC MBMUpgrading firmware Hyper-terminal setup parameters Connect usingProgram responds starting rec 0. Hit any key to continue R2MFC MBM maintenance NN40010-300 Chapter Command Line Interface CLI Users and passwordsOverview Accessing the CLI Command Line Interface CLICommands LOad directory CLI commandsINfo directory CLI commands LOad directoryVIew directory CLI commands VIew directoryCNtrl directory CLI commands Sheet 1 CNtrl directoryNN40010-300 COnfig directory CNtrl directory CLI commands Sheet 3COnfig directory CLI commands Sheet 1 NN40010-300 ALarm directory ALarm directory CLI commands Sheet 1NN40010-300 SWerr directory CLI commands SWerr directoryMFC directory CLI commands Sheet 1 MFC directoryMFC directory CLI commands Sheet 2 See Chapter , MFC Signal Definitions, on page 111 for MFC R2 directory CLI commands Sheet 1 R2 directoryCommand Line Interface CLI R2 directory CLI commands Sheet 2 PRI directory CLI commands PRI directoryCommand Line Interface CLI NN40010-300 Appendix a Configuring DIP switch settings and definitions Shows the Config DIP switch layoutCountry selection DIP switch settings Second dial tone DIP switch settingsCountry code defaults Mexico ConfigMexico Config 1 R2 A/B signals Interpretation of received MFC signals Interpretation of transmitted MFC signals Sheet 1Meaning Signal Mexico Config Mexico Config 2 R2 A/B signals Interpretation of received MFC signals Sheet 1Interpretation of transmitted MFC signals Brazil Config Brazil Config 1 R2 A/B signalsInterpretation of received MFC signals Brazil Config Brazil Config 2 R2 A/B signals Argentina Config Argentina Config 1 R2 A/B Signals Interpretation of received MFC signals Chile Config Chile Config 1 R2 A/B signalsSignal Block Panama Config Configuring DIP switch settings and definitions NN40010-300 Appendix B Diagnostic and loopback DIP switch settings Diagnostics and Loopback Dip Switch SettingsDiagnostic and loopback DIP switch settings NN40010-300 Appendix C MFC Signal Definitions MFC signal definitionsMFC signal meaning MFC Signal Definitions NN40010-300 Appendix D CLI Cable Pinout Cable pinoutsCLI Cable Pinout NN40010-300