Nortel Networks R2MFC manual Hyper-terminal setup parameters, Connect using

Page 70

70 Chapter 6 R2MFC MBM maintenance

Figure 28 Upgrading firmware overview

Firmware Upgrade

Required

Is f irmware corrupted?

No

Yes

Copy the firmware load and PC program files to

PC

Connect PC to the

R2FMC MBM

Open a Hyper-terminal session to connect to

R2FMC MBM

Disable links

Prepare R2FMC MBM for

upload

Upload new firmware

file

Verify the version of

new firmware

Disconnect PC from

R2FMC MBM

Check the module to see if it is working properly

Perform the following steps to download the firmware the R2MFC MBM:

1Copy the firmware load file and the PC program files, bload1.exe, to the same directory on the PC.

2Use the shipped cable, part number N0026100, to connect a PC to the RS-232 port on the faceplate of the R2MFC MBM through COM1.

3Open a new Hyper-terminal session on the PC using the parameters listed in Table 16.:

Table 16 Hyper-terminal setup parameters

Parameter

Setting

 

 

Connect using

COM 1

 

 

Bits per second

19 200

 

 

Data bits

8

 

 

Parity

None

 

 

Stop Bits

1

 

 

Flow Control

None

 

 

4Go to step 11 if the existing firmware is corrupted. Corrupted firmware is indicated if the BOOT program displays:

load, switch, fload, fswitch, checksum, DisMem, DisWord, *=quit

----> user monitor:

5Wait for the monitor line (flashing cursor) to appear on the terminal session.

NN40010-300

Image 70
Contents R2MFC Media Bay Module Installation and Configuration Guide Safety North American Regulatory InformationR2MFC Media Bay Module Installation and Configuration Guide Enhanced 911 ConfigurationRadio-frequency Interference Repairs Important Safety InstructionsHearing Aid Compatibility NN40010-300International Regulatory Information NN40010-300 Contents Chapter Preparing to install the R2MFC MBM Chapter R2MFC MBM maintenance Appendix a Configuring DIP switch settings and definitions MFC Register Signaling Panama Config 1 NN40010-300 Getting Help from the Nortel Web site How to Get HelpGetting Help over the phone from a Nortel Solutions Center Getting Help through a Nortel distributor or resellerHow to Get Help NN40010-300 About this guide Getting startedAudience Before you begin AcronymsSymbols and text conventions Pswd Convention Example Used forRelated publications Getting started NN40010-300 Chapter Overview General informationR2MFC MBM faceplate elements Administration and maintenance toolsOverview Config DIP switches System Status LEDsRS232 port BNC and RJ-48 connectorsR2MFC MBM back and underside elements E1 Status LEDsPower connectors MBM DIP switchesOverview NN40010-300 Chapter Preparing to install the R2MFC MBM Preparing to install the R2MFC MBM Installation process mapHost system setup requirements Host system setup requirementsR2MFC MBM setup requirements Config DIP switchesCustomer supplied hardware requirements Chapter Installing the R2MFC MBM Overview of the R2MFC MBM installationShutting down the system Installing the R2MFC MBMShutting down a BCM 4.0 system Shutting down a BCM 3.7 or lower system Shutting down the BCM 4.0 system hardwareInstalling an R2MFC MBM Installing an R2MFC MBM in the BCM platform base chassisInstalling an R2MFC MBM in the expansion unit Installing an R2MFC MBM in the BCM50 expansion unit Installing the rubber boot in an R2MFC moduleR2MFC Transmit Co-axial cable connected to the MBM Reconnecting the equipment Removing an R2MFC MBMHow to remove a BCM200 R2MFC MBM Removing an R2MFC MBM from the BCM platform base chassisHow to remove a BCM400 R2MFC MBM Removing an R2MFC MBM from the expansion unitWiring an R2MFC MBM How to remove the expansion unit front bezelInstalling the R2MFC MBM Connecting an R2MFC MBM to a service provider Trunk wiring overviewInstalling the R2MFC MBM Chapter Configuring the R2MFC MBM Configuring the R2MFC MBMPhysical line characteristics MFCR2 side External Link configurable parametersE1 framing Line signaling Register signalingMinimum or fixed number length + timer parameters Option Parameters Meaning DefaultConfiguring the MFCR2 external link Setting Config DIP switchesConfig DIP switch layout Creating a customized country codePRI side Internal Link configurable parameters E1 framing default parametersConfiguring the PRI internal link using Element Manager Configuring the PRI internal linkSignaling Layer 2 signaling parametersModule configuration parameters Parameter SettingConfiguring the PRI internal link using Unified Manager BCM lines configuration for R2MFC MBMModule type BCM module configuration for R2MFC MBM Off Turning on second dial tone using Element Manager Turning on second dial toneTurning on second dial tone using Unified Manager Outgoing dialing configuration for second dial toneConfiguring the R2MFC MBM Chapter R2MFC MBM maintenance Inter-working functionalityClock synchronization R2MFC MBM maintenanceTranslation of Subscriber Status Diagnostic and loopback modes Diagnostic toolsSetting the R2MFC MBM to diagnostic mode Mode Description Call AvailabilityAlarms Alarms MeasurementsGroup I Alarms propagation Sheet 1 Alarms propagationIncoming signal errors Alarm CauseFaceplate LEDs R2MFC MBM maintenance Group I Alarms propagation Sheet 2Group II alarms propagation System status monitor LEDsLED Name Yellow LED Error messagesLogs and traces Red LEDOverview of module replacement process Replacing an R2MFC MBMUpgrading firmware Hyper-terminal setup parameters Connect usingProgram responds starting rec 0. Hit any key to continue R2MFC MBM maintenance NN40010-300 Users and passwords Chapter Command Line Interface CLIOverview Accessing the CLI Command Line Interface CLIINfo directory CLI commands CommandsLOad directory CLI commands LOad directoryVIew directory CLI commands VIew directoryCNtrl directory CLI commands Sheet 1 CNtrl directoryNN40010-300 CNtrl directory CLI commands Sheet 3 COnfig directoryCOnfig directory CLI commands Sheet 1 NN40010-300 ALarm directory ALarm directory CLI commands Sheet 1NN40010-300 SWerr directory CLI commands SWerr directoryMFC directory CLI commands Sheet 1 MFC directoryMFC directory CLI commands Sheet 2 See Chapter , MFC Signal Definitions, on page 111 for MFC R2 directory CLI commands Sheet 1 R2 directoryCommand Line Interface CLI R2 directory CLI commands Sheet 2 PRI directory CLI commands PRI directoryCommand Line Interface CLI NN40010-300 Appendix a Configuring DIP switch settings and definitions Shows the Config DIP switch layoutCountry selection DIP switch settings Second dial tone DIP switch settingsMexico Config Country code defaultsMexico Config 1 R2 A/B signals Interpretation of transmitted MFC signals Sheet 1 Interpretation of received MFC signalsMeaning Signal Mexico Config Mexico Config 2 R2 A/B signals Interpretation of received MFC signals Sheet 1Interpretation of transmitted MFC signals Brazil Config Brazil Config 1 R2 A/B signalsInterpretation of received MFC signals Brazil Config Brazil Config 2 R2 A/B signals Argentina Config Argentina Config 1 R2 A/B Signals Interpretation of received MFC signals Chile Config Chile Config 1 R2 A/B signalsSignal Block Panama Config Configuring DIP switch settings and definitions NN40010-300 Appendix B Diagnostic and loopback DIP switch settings Diagnostics and Loopback Dip Switch SettingsDiagnostic and loopback DIP switch settings NN40010-300 MFC signal definitions Appendix C MFC Signal DefinitionsMFC signal meaning MFC Signal Definitions NN40010-300 Appendix D CLI Cable Pinout Cable pinoutsCLI Cable Pinout NN40010-300