Chapter 5 Configuring the R2MFC MBM 55
Figure 21 BCM Bus configuration for R2MFC MBM
6Select Modules on bus > Module 1 from the navigation tree.
The Bus # - Module # Information frame displays. See Figure 22 on page 56.
7Configure the parameters in the Bus# - Module # information frame. See Table 8 for parameters and settings.
See Figure 22 on page 56 for an example of the screen layout for an R2MFC MBM configured on Bus 06.
Table 8 Module configuration parameters
Parameter | Setting |
|
|
Module type | PRI |
|
|
Protocol | Euro |
|
|
Clock source | Primary (if only one trunk |
| module in system; |
| otherwise, it depends on the |
| synchronization scheme of |
| the BCM) |
|
|
Overlap receiving | Y |
|
|
Local number length | According to BCM local |
| dialing plan (customer - |
| dependent) |
|
|