Nortel Networks R2MFC manual Mexico Config 2 R2 A/B signals

Page 96

96Configuring DIP switch settings and definitions

R2 line signaling

Mexico Config 2 R2 signals are according to CCITT standard. See Table 31 for the Mexico Config 2 R2 signal definitions.

Table 31 Mexico Config 2 R2 A/B signals

Forward

 

 

 

Backward

 

 

 

 

 

 

 

 

 

Signal

A

B

 

Signal

A

B

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Idle

1

0

 

Idle

1

0

 

 

 

 

 

 

 

Seize

0

0

 

Seize acknowledge

1

1

 

 

 

 

 

 

 

Clear forward

1

0

 

Answer

0

1

 

 

 

 

 

 

 

 

 

 

 

Clear back

1

1

 

 

 

 

 

 

 

 

 

 

 

Block

1

1

 

 

 

 

 

 

 

Note: CD bits are not used. They are set to 01 in transmit direction, and are ignored in receive direction.

MFC register signaling

MFC signal definitions depends on the stage and the direction of the call; there are four tables of 15 signals each: the first stage uses I signals forward and A signals backward, and the second stage uses II signals forward and B signals backward. The meaning of the signals can also be different when being transmitted or received. Meanings of the MFC signals are configurable. MFC signal tables are part of the country-specific parameters.

Table 32 shows the MFC signal configuration in the R2MFC MBM accessed through the CLI for Mexico Config 2. Table 33 on page 97 shows the MFC transmitted signal configuration in the R2MFC MBM accessed through the CLI for Mexico Config 2. These values are preconfigured by the faceplate DIP switches as shown in Figure 30 on page 92. See Chapter 7, “Command Line Interface (CLI),” on page 73 for information on the CLI.

Table 32 Interpretation of received MFC signals (Sheet 1 of 2)

Meaning

Signal

Meaning

Signal

Meaning

Signal

Meaning

Signal

 

 

 

 

 

 

 

 

FW_Digit_1

I_1

FW_Categ_1

II_1

BW_NextDig

A_1

BW_FreeCharge

B_1

 

 

 

 

 

 

 

 

FW_Digit_2

I_2

FW_Categ_2

II_2

BW_PrevDigit

A_2

BW_Busy

B_2

 

 

 

 

 

 

 

 

FW_Digit_3

I_3

FW_Categ_3

II_3

BW_BCateg

A_3

BW_B_Congest

B_3

 

 

 

 

 

 

 

 

FW_Digit_4

I_4

FW_Categ_4

II_4

BW_A_Congest

A_4

BW_B_Congest

B_4

 

 

 

 

 

 

 

 

FW_Digit_5

I_5

FW_Categ_5

II_5

BW_Category

A_5

BW_Unlocated

B_5

 

 

 

 

 

 

 

 

FW_Digit_6

I_6

FW_Categ_6

II_6

BW_SpeechChrg

A_6

BW_B_Congest

B_6

 

 

 

 

 

 

 

 

FW_Digit_7

I_7

FW_Categ_7

II_7

BW_Prev2Digit

A_7

BW_B_Congest

B_7

 

 

 

 

 

 

 

 

NN40010-300

Image 96
Contents R2MFC Media Bay Module Installation and Configuration Guide Safety North American Regulatory InformationEnhanced 911 Configuration R2MFC Media Bay Module Installation and Configuration GuideRadio-frequency Interference Important Safety Instructions Hearing Aid CompatibilityRepairs NN40010-300International Regulatory Information NN40010-300 Contents Chapter Preparing to install the R2MFC MBM Chapter R2MFC MBM maintenance Appendix a Configuring DIP switch settings and definitions MFC Register Signaling Panama Config 1 NN40010-300 How to Get Help Getting Help over the phone from a Nortel Solutions CenterGetting Help from the Nortel Web site Getting Help through a Nortel distributor or resellerHow to Get Help NN40010-300 Getting started About this guideAudience Before you begin AcronymsSymbols and text conventions Pswd Convention Example Used forRelated publications Getting started NN40010-300 Chapter Overview General informationAdministration and maintenance tools R2MFC MBM faceplate elementsOverview Config DIP switches System Status LEDsBNC and RJ-48 connectors R2MFC MBM back and underside elementsRS232 port E1 Status LEDsPower connectors MBM DIP switchesOverview NN40010-300 Chapter Preparing to install the R2MFC MBM Installation process map Host system setup requirementsPreparing to install the R2MFC MBM Host system setup requirementsR2MFC MBM setup requirements Config DIP switchesCustomer supplied hardware requirements Chapter Installing the R2MFC MBM Overview of the R2MFC MBM installationInstalling the R2MFC MBM Shutting down the systemShutting down a BCM 4.0 system Shutting down a BCM 3.7 or lower system Shutting down the BCM 4.0 system hardwareInstalling an R2MFC MBM Installing an R2MFC MBM in the BCM platform base chassisInstalling an R2MFC MBM in the expansion unit Installing an R2MFC MBM in the BCM50 expansion unit Installing the rubber boot in an R2MFC moduleR2MFC Transmit Co-axial cable connected to the MBM Reconnecting the equipment Removing an R2MFC MBMHow to remove a BCM200 R2MFC MBM Removing an R2MFC MBM from the BCM platform base chassisHow to remove a BCM400 R2MFC MBM Removing an R2MFC MBM from the expansion unitWiring an R2MFC MBM How to remove the expansion unit front bezelInstalling the R2MFC MBM Connecting an R2MFC MBM to a service provider Trunk wiring overviewInstalling the R2MFC MBM Chapter Configuring the R2MFC MBM Configuring the R2MFC MBMMFCR2 side External Link configurable parameters Physical line characteristicsE1 framing Line signaling Register signalingMinimum or fixed number length + timer parameters Option Parameters Meaning DefaultConfiguring the MFCR2 external link Setting Config DIP switchesConfig DIP switch layout Creating a customized country codePRI side Internal Link configurable parameters E1 framing default parametersConfiguring the PRI internal link SignalingConfiguring the PRI internal link using Element Manager Layer 2 signaling parametersModule configuration parameters Parameter SettingConfiguring the PRI internal link using Unified Manager BCM lines configuration for R2MFC MBMModule type BCM module configuration for R2MFC MBM Off Turning on second dial tone using Element Manager Turning on second dial toneTurning on second dial tone using Unified Manager Outgoing dialing configuration for second dial toneConfiguring the R2MFC MBM Chapter R2MFC MBM maintenance Inter-working functionalityR2MFC MBM maintenance Clock synchronizationTranslation of Subscriber Status Diagnostic tools Setting the R2MFC MBM to diagnostic modeDiagnostic and loopback modes Mode Description Call AvailabilityAlarms Alarms MeasurementsAlarms propagation Incoming signal errorsGroup I Alarms propagation Sheet 1 Alarm CauseR2MFC MBM maintenance Group I Alarms propagation Sheet 2 Group II alarms propagationFaceplate LEDs System status monitor LEDsError messages Logs and tracesLED Name Yellow LED Red LEDOverview of module replacement process Replacing an R2MFC MBMUpgrading firmware Hyper-terminal setup parameters Connect usingProgram responds starting rec 0. Hit any key to continue R2MFC MBM maintenance NN40010-300 Chapter Command Line Interface CLI Users and passwordsOverview Accessing the CLI Command Line Interface CLICommands LOad directory CLI commandsINfo directory CLI commands LOad directoryVIew directory CLI commands VIew directoryCNtrl directory CLI commands Sheet 1 CNtrl directoryNN40010-300 COnfig directory CNtrl directory CLI commands Sheet 3COnfig directory CLI commands Sheet 1 NN40010-300 ALarm directory ALarm directory CLI commands Sheet 1NN40010-300 SWerr directory CLI commands SWerr directoryMFC directory CLI commands Sheet 1 MFC directoryMFC directory CLI commands Sheet 2 See Chapter , MFC Signal Definitions, on page 111 for MFC R2 directory CLI commands Sheet 1 R2 directoryCommand Line Interface CLI R2 directory CLI commands Sheet 2 PRI directory CLI commands PRI directoryCommand Line Interface CLI NN40010-300 Appendix a Configuring DIP switch settings and definitions Shows the Config DIP switch layoutCountry selection DIP switch settings Second dial tone DIP switch settingsCountry code defaults Mexico ConfigMexico Config 1 R2 A/B signals Interpretation of received MFC signals Interpretation of transmitted MFC signals Sheet 1Meaning Signal Mexico Config Mexico Config 2 R2 A/B signals Interpretation of received MFC signals Sheet 1Interpretation of transmitted MFC signals Brazil Config Brazil Config 1 R2 A/B signalsInterpretation of received MFC signals Brazil Config Brazil Config 2 R2 A/B signals Argentina Config Argentina Config 1 R2 A/B Signals Interpretation of received MFC signals Chile Config Chile Config 1 R2 A/B signalsSignal Block Panama Config Configuring DIP switch settings and definitions NN40010-300 Appendix B Diagnostic and loopback DIP switch settings Diagnostics and Loopback Dip Switch SettingsDiagnostic and loopback DIP switch settings NN40010-300 Appendix C MFC Signal Definitions MFC signal definitionsMFC signal meaning MFC Signal Definitions NN40010-300 Appendix D CLI Cable Pinout Cable pinoutsCLI Cable Pinout NN40010-300