66Chapter 6 R2MFC MBM maintenance
Table 12 Group I Alarms propagation (Sheet 2 of 2)
Error Condition | Alarm Transmitted to far end | Alarm sent on opposite link |
|
|
|
RAI | AIS | |
|
|
|
FEBE | none | none |
|
|
|
Table 13 shows the reactions for Group II alarms when they persist.
Table 13 Group II alarms propagation
Error Condition | Alarm Transmitted to | Alarm sent on opposite link |
|
|
|
LOS | RAI | AIS |
|
|
|
AIS | RAI | AIS |
|
|
|
OOF | RAI | AIS |
|
|
|
OOMTS16 | RAITS16 | AIS |
AISTS16 | RAITS16 | AIS |
RAI | None | RAI |
|
|
|
RAITS16 | None | RAITS16 |
DCH down | None | AIS |
|
|
|
Faceplate LEDs
There are two sets of LEDs on the faceplate of the R2MFC MBM. The system status LEDs are made up of the Power LED, In Service LED, and Diag LED. Table 14 shows the LEDs and their states.
Table 14 System status monitor LEDs
|
|
| LED Status |
|
|
|
|
|
|
|
|
LED Name | Green Solid | Green Flashing | Red Solid | Red Flashing | OFF |
|
|
|
|
|
|
Power | Active Power | N/A | N/A | N/A | No Power |
|
|
|
|
|
|
Normal Operation | Start Up | N/A | N/A | ||
|
|
|
|
|
|
Diag | N/A | N/A | Test Mode | N/A | Normal Operation |
|
|
|
|
|
|
•As the BCM starts, the In Service LED is Green Flashing.
•Once powered up, the Power LED is set to Green, the In Service LED is set to green, and the Diag LED is off.
•When the MBM is operating properly, the In Service LED is Green Solid.
•During an alarm on the internal PRI link, the In Service LED is off.
•During test mode, the Diag LED is red.