RCA Fibre Channel Switch installation manual Port and switch configuration, Arbff

Page 16

BoardTemp

(1)

-

Degrees

Celsius

22

BoardTemp

(2)

-

Degrees

Celsius

27

SwitchDiagnosticsStatusPassed

SwitchTemperatureStatusNormal

3.If the correct firmware version is loaded but not active, use the fallback command to make it active.

4.If the correct firmware version is not loaded, refer to the SANbox2 Fibre Channel Switch Installer’s/User’s Manual information on how to install firmware.

Port and switch configuration

You must ensure that all the Fibre Channel ports are correctly configured for operation with Grass Valley equipment. With these settings, you can use any port in a SCSI or IP fabric without any further configuration.

1.In administrator mode type the following command at the prompt to enter the configuration mode:

sb5_8port (admin) #> config edit

2.In configuration mode, type the following command at the prompt to view the configuration of all the ports on the switch.

sb5_8port (admin-config) #> set config ports

3. Modify the settings as needed. The following example shows the required settings.

A list of attributes with formatting and current values for the port specified at the command line or port #0 will follow.

Each value that is changed will be set for ALL PORTS.

If you wish to terminate this process before reaching the end of the list press 'q' or 'Q' and the ENTER key to do so.

Configuring ALL ports (displaying values from port number: 0)

----------------------------------------------------------

AdminState

(1=Online, 2=Offline, 3=Diagnostics, 4=Down)

[Online]

LinkSpeed

(1=1Gb/s, 2=2Gb/s, 3=Auto)

[Auto]

PortType

(TL /

GL / G / F / FL / Donor)

[GL]

TLPortMode

(1=TLTargetMode, 2=TLInitiatorMode)

[TLTargetMode]

ISLSecurity

(Any / Ours / None)

[Any]

ALFairness

(True

/ False)

[False]

ARB_FF

(True

/ False)

[False]

InteropCredit

(decimal value, 0-255)

[0]

ExtCredit

(dec value, increments of 11, non-loop only)

[0]

FANEnable

(True

/ False)

[True]

LCFEnable

(True

/ False)

[False]

MFSEnable

(True

/ False)

[True]

MFS_TOV

(decimal value, 10-20480 msec)

[10]

MSEnable

(True

/ False)

[True]

NoClose

(True

/ False)

[False]

16

Fibre Channel Switch

16 April, 2003

Image 16
Contents Fibre Channel Switch Fibre Channel Switch Contents Contents Web Technical Support Phone SupportAuthorized Support Representative Profile Users GroupProduct Support Welcome How to use the manuals Support for your Fibre Channel switchInstalling a Switch in a Profile Video Network Profile System Software Requirements PDR Series Fibre Channel firmware and driver requirements Loading PDR Series firmwareConfiguring Fibre Channel on your PDR Series systems Loading Fibre Channel Server firmwareConfiguring Fibre Channel on your PDR Series Enter administrator mode Configuring your Fibre Channel switchConfigure Ethernet LAN settings Configuring your Fibre Channel switch Verify firmware versionPort and switch configuration ArbffRttov ThresholdMonitoringEnabled True / False Connecting devices to the switch Cable lengthsFabric topology Compatible Fibre Channel DevicesMonitoring your switch with NetCentral Snmp configuration Fibre Channel Switch Setting port aliases Monitoring Status Monitoring Status Troubleshooting with NetCentral Resetting the switch to factory defaults Resetting the switch manuallyFibre Channel Switch