Configuring your Fibre Channel switch
AdminTimeout | (dec value | [30] |
TempMonitoringWarning | (dec value | [65] |
TempMonitoringFailure | (dec value | [70] |
TempFailurePortShutdown | (True / False) | [False] |
SecurityEnabled | (True / False) | [False] |
LocalLogEnabled | (True / False) | [True] |
RemoteLogEnabled | (True / False) | [False] |
RemoteLogHostAddress | [10.0.0.254] |
Do you want to save and activate this system setup? (y/n): [n] y
Verify firmware version
You can use the show switch command to view switch information and confirm that the active firmware version is correct. The minimum qualified image is:
• 1.5.0.8 or higher
Contact your Grass Valley representative to determine the current required version.
To view the current version information:
1.In administrator mode type the following command at the prompt,: sb5_8port (admin) #> show switch
2.View the switch information, an example of which is shown here. Note that the ActiveSWImage specifies which SWImageVersion is being used. In this case, it’s image 2.
Switch Information |
|
| |
SymbolicName | sb5_8port |
SwitchWWN | 10:00:00:c0:dd:01:a6:47 |
SwitchType | |
PROMVersion | |
CreditPool | 0 |
DomainID | 100 (0x64) |
FirstPortAddress | 640000 |
FlashSize - MBytes | 128 |
LogLevel | Critical |
MaxPorts | 8 |
NumberOfResets | 17 |
ReasonForLastReset | PowerUp |
SWImageVersion (1) - build date | |
SWImageVersion (2) - build date | |
ActiveConfiguration | default |
ActiveSWImage | 2 |
AdminState | Online |
AdminModeActive | True |
BeaconOnStatus | False |
OperationalState | Online |
PrincipalSwitchRole | False |
16 April, 2003 | Fibre Channel Switch | 15 |