RCA Fibre Channel Switch installation manual Rttov

Page 17

 

 

 

 

Configuring your Fibre Channel switch

IOStreamGuard

(Enable

/ Disable)

[Disabled]

VIEnable

(True

/

False)

[False]

CheckAlps

(True

/

False)

[False]

Finished configuring attributes.

This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect. To discard this configuration use the config cancel command.

4.In configuration mode, type the following command at the prompt configure global switch settings:

sb5_8port (admin-config) #> set config switch

5.Type the following command to configure advanced settings: sb5_8port (admin-config) #> set advanced on

6.Modify the settings as needed. The following example shows the required settings. Pay particular attention to the Multiframe Sequencing Mode (sometimes called Tachyon Mode) MFSMode setting, which must be Hard.

NOTE: Each QLogic SANbox2 Switch must have a unique DomainID for the local fabric. You should specify these values individually for each switch and not allowing the switches to select their own DomainID values. Setting DomainIDLock to True prevents the switch from changing the DomainID when a new switch is added to fabric.

A list of attributes with formatting and current values will follow. Enter a new value or simply press the ENTER key to accept the current value. If you wish to terminate this process before reaching the end of the list

press 'q' or 'Q' and the ENTER key to do so.

AdminState

(1=Online, 2=Offline, 3=Diagnostics)

[Online]

BroadcastEnabled

(True / False)

 

[True]

InbandEnabled

(True / False)

 

[True]

DefaultDomainID

(decimal value, 1-239)

 

[100]

DomainIDLock

(True / False)

 

[True]

SymbolicName

(string, max=32 chars)

 

[sb5_8port]

R_T_TOV

(decimal value, 1-1000 msec)

 

[100]

R_A_TOV

(decimal value, 100-100000 msec)

 

[2000]

E_D_TOV

(decimal value, 10-20000 msec)

 

[1000]

FS_TOV

(decimal value, 100-100000 msec)

 

[5000]

DS_TOV

(decimal value, 100-100000 msec)

 

[5000]

MFSMode

(Hard / Soft)

 

[Hard]

PrincipalPriority

(decimal value, 1-255)

 

[254]

ConfigDescription

(string, max=64 chars)

[SANbox2-8 FC Switch]

Finished configuring attributes.

This configuration must be saved (see config save command) and activated (see config activate command) before it can take effect.

16 April, 2003

Fibre Channel Switch

17

Image 17
Contents Fibre Channel Switch Fibre Channel Switch Contents Contents Phone Support Web Technical SupportAuthorized Support Representative Profile Users GroupProduct Support Welcome Support for your Fibre Channel switch How to use the manualsInstalling a Switch in a Profile Video Network Profile System Software Requirements Loading PDR Series firmware PDR Series Fibre Channel firmware and driver requirementsLoading Fibre Channel Server firmware Configuring Fibre Channel on your PDR Series systemsConfiguring Fibre Channel on your PDR Series Configure Ethernet LAN settings Configuring your Fibre Channel switchEnter administrator mode Verify firmware version Configuring your Fibre Channel switchArbff Port and switch configurationRttov ThresholdMonitoringEnabled True / False Cable lengths Connecting devices to the switchFabric topology Compatible Fibre Channel DevicesMonitoring your switch with NetCentral Snmp configuration Fibre Channel Switch Setting port aliases Monitoring Status Monitoring Status Troubleshooting with NetCentral Resetting the switch manually Resetting the switch to factory defaultsFibre Channel Switch