B&K 1652, 1651A instruction manual Operating Instructions

Page 25

__________________________________________________________________________OPERATING INSTRUCTIONS

In the series tracking mode, the maximum output voltage of both the “A” and “B” supplies can be simultaneously varied with one control. The maximum “B” supply voltage can be set to the same value of the “A” supply by using the “A” VOLTAGE control.

The output voltage (across the two supplies) is actually double the Volt meter reading. The actual output current would be the value read from the mA meter (since the two supplies are wired in series, current flowing through each supply must be equal).

1.Set the power supplies to the TRACKING SERIES mode by setting the TRACKING/INDEPENDENT switch to the SERIES (left) position.

2.Set the A/B Metering switch to the A (up) position.

3.The “B” VOLTAGE AND CURRENT controls are disabled; turn both to their minimum positions. The maximum current is set using the “A” CURRENT control. Follow the instructions for “Setting Current Limit” (INDEPENDENT USE OF “A” OR “B” SUPPLY section of this manual) using the “A” CURRENT control.

4.Adjust the output voltage to the desired level using the “A” VOLTAGE control (remember that the actual output voltage is double the reading on the Volt meter).

5.Turn off the power supply and the equipment to be powered during hook-up.

6.Connect the positive polarity of the device being powered to the red (+) terminal of the “A” power supply.

7.Connect the negative polarity of the device being powered to the black (-) terminal of the “B” power supply.

Figure 8. Series tracking (0-to-48 V) operation

grounding possibilities (sheet 3 of 3).

8.Fig. 8 illustrates the grounding possibilities when the unit is used as a 0-to-48 \volt supply.

a. If the negative polarity of the equipment or circuit being powered is also the chassis or common, it

21 may be grounded to earth by connecting the black (-) terminal of the “B” supply to the green (GND) terminal as shown in Fig. 8A.

Image 25
Contents Instruction Manual Test Instrument Safety DC Power Supply Table of Contents Introduction Introduction Features Overload Protection Isolated OutputReverse Polarity Protection HOOK-UP CablesB Supplies SpecificationsGeneral Fixed 5V SupplySupply Controls and Indicators Controls and IndicatorsControls and Indicators Constant Current Indicator Line Voltage Select Switches. Combination Fixed 5V Supply Terminals and Indicator Rear Panel ControlsRear panel controls Equipment Precautions Safety PrecautionsOperating Instructions Independent USE of a or B SupplyOperating Instructions Hook-up Operating Instructions Independent operation grounding possibilities sheet 2 Setting Current Limit Setting Current limit Series Tracking Operation Constant voltage/constant current characteristicOperating Instructions Operating Instructions Operating Instructions Parallel Tracking Operation Parallel tracking operation grounding possibilities sheet 1 Parallel tracking operation grounding possibilities sheet 2 Fixed 5 V Power Supply Operation Grounding possibilities for fixed 5 V power supply sheet 1 Grounding possibilities for fixed 5 V power supply sheet 2 Operating Instructions Electronics Servicing ApplicationsElectronics Manufacturing Electronics Design LAB Battery ChargingElectronics Education Split SupplyPage Page Page Page Page Page Fuse Replacement MaintenanceService Information Limited One-Year Warranty Test Instrument Safety Manual DE Instrucciónes Fuente DE Poder DE CD Triple Seguridad DEL Instrumento DE Prueba Advertencia Instrucciones DE Operación Seguridad DEL Instrumento DE PruebaIntroduccion Fuente Fija DE Salida TripleDOS Fuentes DE O a Característica DE Rastreo UnicaProtección Contra Sobreflujo Salida AisladaProtección DE Polaridad Inversa Cables Fuentes a Y B EspecificacionesGeneral Controles E Indicadores Figura 1. Controles e indicadores del panel frontal Controles E Indicadores DE LA Fuente B Indicador Constant CurrentControles DEL Panel Trasero Indicadores Y Controles DE LA Fuente DEFigura 2. Controles del panel trasero USO Independiente DE LA Fuente a O B Precauciones Para SeguridadInstrucciones DE Operación Page Page Figura 4. Operación de voltaje constante típica Operación de corriente constante típica Operación DE Rastreo EN Serie Característica de voltaje constante/corriente constantePage Page Instrucciones DE Operación Operación DE Rastreo EN Paralelo Page Page Operación DE LA Fuente Fija DE Page Page Instrucciones DE Operación Manufactura Electrónica Servicio ElectrónicoEducación EN Electrónica Laboratorio DE Diseño ElectrónicoCarga DE Baterias Fuente DivididaAplicaciones Aplicaciones Aplicaciones Aplicaciones Aplicaciones Aplicaciones Mantenimiento Información de Servicio Garantía Limitada de Un Ano Seguridad DE EL Equipo DE Prueba Declaration of CE Conformity Savi Ranch Parkway Yorba Linda, CA 2005 B&K Precision Corp