SPECIFICATIONS
“A” AND “B” SUPPLIES
Output Voltage Range:
0V to 24VDC (0 ± 100mV)
Output Current Limit Range:
0 to 0.5A.
Constant Voltage Operation:
Voltage Regulation: |
|
Load: | ≤0.01% + 3mV |
Line (108 – 132V): | ≤0.01% + 3mV |
Ripple Noise: | ≤2mVrms (5Hz to 1MHz) |
Recovery Time: | ≤100us typical. |
Temp. Coefficient |
|
0°C to 40°C | ≤300ppm/°C |
Tracking Error: |
|
No Load: | ≤0.2% + 20mV |
Full Load: | ≤0.2% + 100mV |
Constant Current Operation: |
|
Adjustable Current Limits: | ≤30mA to ≥500mA |
Current Regulation: |
|
Load: | ≤0.2% + 6mA. |
Line (108 – 132V): | ≤0.2% + 3mA. |
Ripple Current and Noise: | ≤3mA rms. |
Metering (“A” & “B” only): |
|
Voltmeter: |
|
Range: | 0 to 25V |
Accuracy: | ≤2.5% of Full Scale |
| ±2% + 2 digits |
| (1652) |
Ampmeter: |
|
Range: | 0 to 600mA |
Accuracy: | ≤2.5% of Full Scale |
| ±2% + 2 digits |
| (1652) |
5